The effect of concomitant gradient fields on diffusion tensor imaging

被引:51
|
作者
Baron, C. A. [1 ]
Lebel, R. M. [1 ]
Wilman, A. H. [1 ]
Beaulieu, C. [1 ]
机构
[1] Univ Alberta, Fac Med & Dent, Dept Biomed Engn, Res Transit Facil 1064, Edmonton, AB T6G 2V2, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
DTI; concomitant fields; diffusion; gradient; REFOCUSED SPIN-ECHO; MAGNETIC-FIELD; MRI; ANISOTROPY; ARTIFACTS; RECONSTRUCTION; REDUCTION; SEQUENCE; MOTION; BRAIN;
D O I
10.1002/mrm.24120
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Concomitant gradient fields are transverse magnetic field components that are necessarily present to satisfy Maxwell's equations when magnetic field gradients are utilized in magnetic resonance imaging. They can have deleterious effects that are more prominent at lower static fields and/or higher gradient strengths. In diffusion tensor imaging schemes that employ large gradients that are not symmetric about a refocusing radiofrequency pulse (unlike StejskalTanner, which is symmetric), concomitant fields may cause phase accrual that could corrupt the diffusion measurement. Theory predicting the error from this dephasing is described and experimentally validated for both Reese twice-refocused and split gradient single spin-echo diffusion gradient schemes. Bias in apparent diffusion coefficient values was experimentally found to worsen with distance from isocenter and with increasing duration of gradient asymmetry in both a phantom and in the brain. The amount of error from concomitant gradient fields depends on many variables, including the diffusion gradient pattern, pulse sequence timing, maximum effective gradient amplitude, static magnetic field strength, voxel size, slice distance from isocenter, and partial Fourier fraction. A prospective correction scheme that can reduce concomitant gradient errors is proposed and verified for diffusion imaging. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1190 / 1201
页数:12
相关论文
共 50 条
  • [41] Limbic-Auditory Interactions of Tinnitus: An Evaluation Using Diffusion Tensor Imaging
    Gunbey, H. P.
    Gunbey, E.
    Aslan, K.
    Bulut, T.
    Unal, A.
    Incesu, L.
    CLINICAL NEURORADIOLOGY, 2017, 27 (02) : 221 - 230
  • [42] The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems
    Tao, Shengzhen
    Weavers, Paul T.
    Trzasko, Joshua D.
    Huston, John, III
    Shu, Yunhong
    Gray, Erin M.
    Foo, Thomas K. F.
    Bernstein, Matt A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1354 - 1364
  • [43] Role of diffusion tensor imaging in differentiating subtypes of meningiomas
    Jolapara, M.
    Kesavadas, C.
    Radhakrishnan, V. V.
    Thomas, B.
    Gupta, A. K.
    Bodhey, N.
    Patro, S.
    Saini, J.
    George, U.
    Sarma, P. S.
    JOURNAL OF NEURORADIOLOGY, 2010, 37 (05) : 277 - 283
  • [44] Diffusion tensor imaging in cervical spondylotic myelopathy: a review
    Shabani, Saman
    Kaushal, Mayank
    Budde, Matthew D.
    Wang, Marjorie C.
    Kurpad, Shekar N.
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (01) : 65 - 72
  • [45] Effect of head size on diffusion tensor imaging
    Takao, Hidemasa
    Hayashi, Naoto
    Inano, Sachiko
    Ohtomo, Kuni
    NEUROIMAGE, 2011, 57 (03) : 958 - 967
  • [46] Basic Concepts of MR Imaging, Diffusion MR Imaging, and Diffusion Tensor Imaging
    de Figueiredo, Eduardo H. M. S. G.
    Borgonovi, Arthur F. N. G.
    Doring, Thomas M.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2011, 19 (01) : 1 - +
  • [47] Comparison of Gradient Encoding Directions for Higher Order Tensor Diffusion Data
    Mang, Sarah C.
    Gembris, Daniel
    Grodd, Wolfgang
    Klose, Uwe
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 335 - 343
  • [48] Diffusion-weighted imaging and diffusion tensor imaging in preoperative diagnostics
    Reith, W.
    RADIOLOGE, 2015, 55 (09): : 775 - 781
  • [49] Predictive value of flexion and extension diffusion tensor imaging in the early stage of cervical myelopathy
    Tykocki, Tomasz
    English, Philip
    Minks, David
    Krishnakumar, Arunkumar
    Wynne-Jones, Guy
    NEURORADIOLOGY, 2018, 60 (11) : 1181 - 1191
  • [50] Isotropic resolution diffusion tensor imaging with whole brain acquisition in a clinically acceptable time
    Jones, DK
    Williams, SCR
    Gasston, D
    Horsfield, MA
    Simmons, A
    Howard, R
    HUMAN BRAIN MAPPING, 2002, 15 (04) : 216 - 230