Diagnostic Accuracy of Dynamic Contrast-Enhanced MR Imaging Using a Phase-Derived Vascular Input Function in the Preoperative Grading of Gliomas

被引:33
作者
Nguyen, T. B. [1 ]
Cron, G. O. [1 ]
Mercier, J. F. [1 ]
Foottit, C. [2 ]
Torres, C. H. [1 ]
Chakraborty, S. [1 ]
Woulfe, J. [3 ]
Jansen, G. H. [3 ]
Caudrelier, J. M. [1 ]
Sinclair, J. [4 ]
Hogan, M. J. [5 ]
Thornhill, R. E. [1 ]
Cameron, I. G. [1 ,2 ]
机构
[1] Univ Ottawa, Ottawa Hosp, Dept Radiol, Ottawa, ON K1Y 4E9, Canada
[2] Univ Ottawa, Ottawa Hosp, Dept Med Phys, Ottawa, ON K1Y 4E9, Canada
[3] Univ Ottawa, Ottawa Hosp, Dept Pathol, Ottawa, ON K1Y 4E9, Canada
[4] Univ Ottawa, Ottawa Hosp, Dept Surg, Div Neurosurg, Ottawa, ON K1Y 4E9, Canada
[5] Univ Ottawa, Ottawa Hosp, Dept Med, Div Neurol, Ottawa, ON K1Y 4E9, Canada
关键词
BLOOD-VOLUME; QUANTIFICATION; PERMEABILITY; EXCHANGE; LEAKAGE; TRACER; T-1;
D O I
10.3174/ajnr.A3012
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The accuracy of tumor plasma volume and K-trans estimates obtained with DCE MR imaging may have inaccuracies introduced by a poor estimation of the VIF. In this study, we evaluated the diagnostic accuracy of a novel technique by using a phase-derived VIE and "bookend" T1 measurements in the preoperative grading of patients with suspected gliomas. MATERIALS AND METHODS: This prospective study included 46 patients with a new pathologically confirmed diagnosis of gnome. Both magnitude and phase images were acquired during DCE MR imaging for estimates of K-trans_phi and V-p_phi (calculated from a phase-derived VIF and bookend T1 measurements) as well as K-trans_SI and V-p_SI (calculated from a magnitude-derived VIF without T1 measurements). RESULTS: Median K-trans_phi values were 0.0041 minutes(-1) (95% CI, 0.00062-0.033), 0.031 minutes(-1) (0.011-0.150), and 0.088 minutes(-1) (0.069-0.110) for grade II, III, and IV gliomas, respectively (P <= .05 for each). Median V-p_phi values were 0.64 mL/100 g (0.06-1.40), 0.98 mL/100 g (0.34-2.20), and 2.16 mL/100 g (1.8-3.1) with P = .15 between grade II and III gliomas and P = .015 between grade III and IV gliomas. In differentiating low-grade from high-grade gliomas, AUCs for K-trans_phi, V-p_phi K-trans_SI, and V-p_SI were 0.87 (0.73-1), 0.84 (0.69-0.98), 0.81 (0.59.1), and 0.84 (0.66-0.91). The differences between the AUCs were not statistically significant. CONCLUSIONS: K-trans_phi and V-p_phi are parameters that can help in differentiating low-grade from high-grade gliomas.
引用
收藏
页码:1539 / 1545
页数:7
相关论文
共 23 条
  • [1] Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements
    Brix, Gunnar
    Griebel, Juergen
    Kiessling, Fabian
    Wenz, Frederik
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S30 - S51
  • [2] Contrast agent concentration measurements affecting quantification of bolus-tracking perfusion MRI
    Calamante, Fernando
    Vonken, Evert-jan P. A.
    van Osch, Matthias J. P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 544 - 553
  • [3] Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements
    Cron, GO
    Kelcz, F
    Santyr, GE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 1066 - 1070
  • [4] Arterial Input Functions Determined From MR Signal Magnitude and Phase for Quantitative Dynamic Contrast-Enhanced MRI in the Human Pelvis
    Cron, Greg O.
    Foottit, Claire
    Yankeelov, Thomas E.
    Avruch, Leonard I.
    Schweitzer, Mark E.
    Cameroni, Ian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 498 - 504
  • [5] de Bruin PW, 2011, P 19 ANN M INT SOC M
  • [6] Water diffusion and exchange as they influence contrast enhancement
    Donahue, KM
    Weisskoff, RM
    Burstein, D
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 102 - 110
  • [7] Determination of the Venous Output Function From MR Signal Phase: Feasibility for Quantitative DCE-MRI in Human Brain
    Foottit, Claire
    Cron, Greg O.
    Hogan, Matthew J.
    Nguyen, Thanh Binh
    Cameron, Ian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 772 - 781
  • [8] Optimized Preload Leakage-Correction Methods to Improve the Diagnostic Accuracy of Dynamic Susceptibility-Weighted Contrast-Enhanced Perfusion MR Imaging in Posttreatment Gliomas
    Hu, L. S.
    Baxter, L. C.
    Pinnaduwage, D. S.
    Paine, T. L.
    Karis, J. P.
    Feuerstein, B. G.
    Schmainda, K. M.
    Dueck, A. C.
    Debbins, J.
    Smith, K. A.
    Nakaji, P.
    Eschbacher, J. M.
    Coons, S. W.
    Heiserman, J. E.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (01) : 40 - 48
  • [9] Kim J, 2011, P 19 ANN M INT SOC M
  • [10] Water exchange and inflow affect the accuracy of T1-GRE blood volume measurements:: Implications for the evaluation of tumor angiogenesis
    Kim, YR
    Rebro, KJ
    Schmainda, KM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1110 - 1120