Influence of impurities on the specific optical rotation of cefozopran

被引:3
作者
Liu, Shu-Yu [1 ,2 ]
Li, Ya-Ping [1 ]
Hu, Chang-Qin [1 ]
机构
[1] Natl Inst Food & Drug Control, Beijing 100050, Peoples R China
[2] Shanghai Univ Engn Sci, Shanghai, Peoples R China
来源
PHARMAZIE | 2012年 / 67卷 / 07期
关键词
D O I
10.1691/ph.2012.1133
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The impurities of cefozopran hydrochloride are analyzed using high-performance liquid chromatography (HPLC) with UV absorbance and optical rotation (OR) detection. The results show that the impurities can affect the specific optical rotation of the cefozopran product. Due to the different composition of impurities, the Chinese cefozopran hydrochloride product has a specific optical rotation different from the Japanese product. The relationship between impurity limits and specific optical rotation of cefozopran hydrochloride is revealed. The results provide a scientific rationale for setting the limit of specific optical rotation of cefozopran hydrochloride.
引用
收藏
页码:590 / 594
页数:5
相关论文