Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

被引:57
|
作者
Wang, Adam S. [1 ]
Stayman, J. Webster [1 ]
Otake, Yoshito [1 ]
Kleinszig, Gerhard [2 ]
Vogt, Sebastian [2 ]
Gallia, Gary L. [3 ]
Khanna, A. Jay [4 ]
Siewerdsen, Jeffrey H. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Siemens Healthcare XP Div, Erlangen, Germany
[3] Johns Hopkins Univ, Dept Neurosurg, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Dept Orthoped Surg, Baltimore, MD 21205 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 04期
关键词
cone-beam CT; statistical reconstruction; image reconstruction; sparse sampling; soft-tissue imaging; image-guided surgery; mobile C-arm; FLAT-PANEL-DETECTOR; LOW-DOSE CT; COMPUTED-TOMOGRAPHY; ITERATIVE RECONSTRUCTION; ABDOMINAL CT; ORDERED SUBSETS; BACK-PROJECTION; CALIBRATION; REDUCTION; GUIDANCE;
D O I
10.1088/0031-9155/59/4/1005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The potential for statistical image reconstruction methods such as penalized-likelihood (PL) to improve C-arm cone-beam CT (CBCT) soft-tissue visualization for intraoperative imaging over conventional filtered backprojection (FBP) is assessed in this work by making a fair comparison in relation to soft-tissue performance. A prototype mobile C-arm was used to scan anthropomorphic head and abdomen phantoms as well as a cadaveric torso at doses substantially lower than typical values in diagnostic CT, and the effects of dose reduction via tube current reduction and sparse sampling were also compared. Matched spatial resolution between PL and FBP was determined by the edge spread function of low-contrast (similar to 40-80 HU) spheres in the phantoms, which were representative of soft-tissue imaging tasks. PL using the non-quadratic Huber penalty was found to substantially reduce noise relative to FBP, especially at lower spatial resolution where PL provides a contrast-to-noise ratio increase up to 1.4-2.2x over FBP at 50% dose reduction across all objects. Comparison of sampling strategies indicates that soft-tissue imaging benefits from fully sampled acquisitions at dose above similar to 1.7 mGy and benefits from 50% sparsity at dose below similar to 1.0 mGy. Therefore, an appropriate sampling strategy along with the improved low-contrast visualization offered by statistical reconstruction demonstrates the potential for extending intraoperative C-arm CBCT to applications in soft-tissue interventions in neurosurgery as well as thoracic and abdominal surgeries by overcoming conventional tradeoffs in noise, spatial resolution, and dose.
引用
收藏
页码:1005 / 1026
页数:22
相关论文
共 50 条
  • [41] Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach
    Cho, Sanghoon
    Lim, Sunho
    Kim, Changhwan
    Wi, Sunhee
    Kwon, Taejin
    Youn, Won Sik
    Lee, Sang Hyun
    Kang, Bo Sun
    Cho, Seungryong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 70 : 1 - 9
  • [42] Cone-Beam CT of Traumatic Brain Injury Using Statistical Reconstruction with a Post-Artifact-Correction Noise Model
    Dang, H.
    Stayman, J. W.
    Sisniega, A.
    Xu, J.
    Zbijewski, W.
    Yorkston, J.
    Aygun, N.
    Koliatsos, V.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [43] Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics
    Tward, D. J.
    Siewerdsen, J. H.
    Daly, M. J.
    Richard, S.
    Moseley, D. J.
    Jaffray, D. A.
    Paul, N. S.
    MEDICAL PHYSICS, 2007, 34 (11) : 4459 - 4471
  • [44] C-arm cone-beam CT parenchymal blood volume imaging for transarterial chemoembolization of hepatocellular carcinoma: implications for treatment planning and response
    O'Donohoe, Rory L.
    Kavanagh, Richard G.
    Cahalane, Alexis M.
    Houlihan, Diarmaid D.
    McCann, Jeffrey W.
    Ryan, Edmund Ronan
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01)
  • [45] C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules
    Hwang, Hye Sun
    Chung, Myung Jin
    Lee, Ju Won
    Shin, Sung Wook
    Lee, Kyung Soo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : W400 - W407
  • [46] Shading correction assisted iterative cone-beam CT reconstruction
    Yang, Chunlin
    Wu, Pengwei
    Gong, Shutao
    Wang, Jing
    Lyu, Qihui
    Tang, Xiangyang
    Niu, Tianye
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (22): : 8495 - 8520
  • [47] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [48] L1 and Total Variation Regularized C-arm Cardiac Cone Beam CT Reconstruction
    Liu, Bo
    Zhou, Fugen
    2013 INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL MODELS FOR LIFE SCIENCES, 2013, 1559 : 313 - 314
  • [49] Flat-panel cone-beam CT on a mobile isocentric C-arm for image-guided brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, G
    Wong, J
    Martinez, A
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 209 - 217
  • [50] C-arm Fluoroscopic Cone Beam CT for Guidance of Minimally Invasive Spine Interventions
    Powell, Michael F.
    DiNobile, Diane
    Reddy, Arra S.
    PAIN PHYSICIAN, 2010, 13 (01) : 51 - 59