Cemented Hip Revision Surgery in Severe Acetabular Defects Using a Semirigid Acetabular Reinforcement Ring-a 5-to 25-Year Follow-Up Study

被引:7
作者
Haverkamp, Daniel [1 ]
De Man, F. Harald R. [1 ]
Slegt, Raoul [1 ]
Besselaar, Philip P. [1 ]
Marti, Rene K. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Orthopaed Surg, Orthopaed Res Ctr, NL-1100 DD Amsterdam, Netherlands
关键词
hip; osteoarthritis; arthroplasty; revision; acetabular defects; QUANTITATIVE COMPUTED-TOMOGRAPHY; ANTI-PROTRUSIO CAGE; PRESS-FIT; ANTIPROTRUSIO CAGE; BONE-GRAFT; ARTHROPLASTY; REPLACEMENT; RECONSTRUCTION; DYSPLASIA; DEFICIENCY;
D O I
10.1016/j.arth.2008.07.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Between 1978 and 1998, a total of 38 consecutive acetabular component revisions were performed in 38 patients. Average age was 67 years, and 87% of patients had severe uncontained segmental acetabular defects of more than 50%. We describe the operative technique of acetabular component revisions performed with bone grafting and a steel, semirigid acetabular reinforcement ring (Eichler), and long-term results are presented. After an average of 11.2 years follow-up, I CLIP was revised after 0.8 years for mechanical loosening, but the ring remained stably fixed. Remodeling (partial) of autografts Occurred in all cases. The average HHS was 72.5. The Eichler reinforcement ring is a viable option for segmental acetabular defects in revision hip surgery, allows for restoration of pelvic bone, and makes future revisions feasible.
引用
收藏
页码:246 / 255
页数:10
相关论文
共 50 条
  • [41] Acetabular Fractures in the Elderly Treated With a Primary Burch-Schneider Reinforcement Ring, Autologous Bone Graft, and a Total Hip Arthroplasty: A Prospective Study With a 4-Year Follow-Up
    Enocson, Anders
    Blomfeldt, Richard
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (06) : 330 - 337
  • [42] Acetabular microfracture in hip arthroscopy: clinical outcomes with minimum 5-year follow-up
    Domb, Benjamin G.
    Rybalko, Danil
    Mu, Brian
    Litrenta, Jody
    Chen, Austin W.
    Perets, Itay
    HIP INTERNATIONAL, 2018, 28 (06) : 649 - 656
  • [43] The use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4- to 9-year follow-up
    Huifeng Ding
    Yuanqing Mao
    Bin Yu
    Zhenan Zhu
    Huiwu Li
    Baoqing Yu
    Jianming Huang
    Journal of Orthopaedic Surgery and Research, 10
  • [44] Treatment of Crowe Type-IV Hip Dysplasia Using Cementless Total Hip Arthroplasty and Double Chevron Subtrochanteric Shortening Osteotomy: A 5-to 10-Year Follow-Up Study
    Li, Xigong
    Lu, Yang
    Sun, Junying
    Lin, Xiangjin
    Tang, Tiansi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02) : 475 - 479
  • [45] Screws are not needed when secure interference fit of uncemented acetabular components is adequate: a 5-to 15-year follow-up with clinical and radiological analysis
    Garcia-Rey, Eduardo
    HIP INTERNATIONAL, 2017, 27 (03) : 267 - 272
  • [46] Acetabular reconstruction for primary and revision total hip arthroplasty using Kerboull-type acetabular reinforcement devices-case-control study with factors related to poor outcomes of surgery
    Masumoto, Yoshinobu
    Fukunishi, Shigeo
    Fukui, Tomokazu
    Takeda, Yu
    Nishio, Shoji
    Fujihara, Yuki
    Okahisa, Shohei
    Okada, Taishi
    Yoshiya, Shinichi
    MEDICINE, 2019, 98 (27) : e16090
  • [47] 2- to 10-year follow-up study of acetabular revisions using allograft bone to repair bone defects
    Avci, S
    Connors, N
    Petty, W
    JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 61 - 69
  • [48] Acetabular component revision with frozen massive structural pelvic allograft - Average 5-year follow-up
    Piriou, P
    Sagnet, F
    Norton, MR
    de Loubresse, CG
    Judet, T
    JOURNAL OF ARTHROPLASTY, 2003, 18 (05) : 562 - 569
  • [49] High incidence of loosening at 5-year follow-up of a cemented metal-on-metal acetabular component in THR
    Descamps, S.
    Bouillet, B.
    Boisgard, S.
    Levai, J. P.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2009, 19 (08) : 559 - 563
  • [50] Acetabular Augments Used in Revision Hip Arthroplasty: Minimum 10-year Follow-Up of Implant Survivorships, Functional Scores, and Radiographic Outcomes
    Braunstein, Doris
    Greenberg, Arieh
    Chaudhry, Faran
    Daud, Anser
    Sa, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R.
    JOURNAL OF ARTHROPLASTY, 2025, 40 (03) : 751 - 757