Comparison of patient-prothesis mismatch after surgical aortic valve replacement and transcatheter aortic valve implantation

被引:1
|
作者
Yilmaz, Bilge Ecemis [1 ]
Karacalilar, Mehmet [1 ]
Ersoy, Burak [1 ]
Onan, Burak [1 ]
机构
[1] Univ Hlth Sci, Mehmet Akif Ersoy Thorac & Cardiovasc Surg Traini, Dept Cardiovasc Surg, Istanbul, Turkey
来源
TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY | 2019年 / 27卷 / 02期
关键词
Patient-prosthesis mismatch; aortic valve replacement; transcatheter aortic valve implantation; HIGH-RISK PATIENTS; PROSTHESIS MISMATCH; OUTCOMES; STENOSIS; IMPACT;
D O I
10.5606/tgkdc.dergisi.2019.17174
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of this study is to analyze the outcomes and incidence of postoperative patient-prothesis mismatch after surgical aortic valve replacement using supra-annular bioprosthesis and transcatheter aortic valve implantation. Methods: Between January 2012 and June 2015, a total of 73 patients (37 males, 36 females; mean age 71.8 +/- 5.7 years; range, 65 to 82 years) who underwent either surgical aortic valve replacement using supraannular bioprosthesis (n=36) or transcatheter aortic valve implantation (n=37) were included. Postoperative patient-prothesis mismatch was defined as absent, mild-to-moderate, and severe, if the indexed effective orifice area was >0.85 cm(2)/m(2), >0.65 to <0.85 cm(2)/m(2), and <0.65 cm(2)/m(2), respectively. Both groups were compared in terms of patient-prothesis mismatch, postoperative outcomes, and mortality. Results: The overall incidence of mild-to-moderate patient-prosthesis mismatch was 17.8% (13/73). No severe patient-prosthesis mismatch was observed. Mild-to-moderate patient-prosthesis mismatch was found in three patients (8.1%) in the transcatheter group and in 10 patients (27.8%) in the surgery group (p=0.035). Body surface area was the significant predictor of patient-prosthesis mismatch (p=0.007). Diameters of bioprosthetic valves in the surgery and transcatheter groups were 21.4 +/- 2 and 23.9 +/- 2.6 mm, respectively (p=0.002). Early mortality and pacemaker implantation rates were higher in the transcatheter group (p>0.05). Postoperative outcomes were similar between the groups. Mid-term mortality at a mean follow-up of 47.7 +/- 7.3 months was similar between the groups (p=0.158). Conclusion: In high-risk patients with severe aortic stenosis, patient-prosthesis mismatch is mild-to-moderate after surgical aortic valve replacement and transcatheter aortic valve implantation; however, this has no effect on early mortality. Based on our study results, we suggest that the use of surgical approach for aortic valve replacement may prevent potential complications of transcatheter aortic valve implantation.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 50 条
  • [31] Transcatheter and surgical aortic valve replacement in patients with bicuspid aortic valve
    Husso, Annastiina
    Airaksinen, Juhani
    Juvonen, Tatu
    Laine, Mika
    Dahlbacka, Sebastian
    Virtanen, Marko
    Niemela, Matti
    Makikallio, Timo
    Savontaus, Mikko
    Eskola, Markku
    Raivio, Peter
    Valtola, Antti
    Biancari, Fausto
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (03) : 429 - 439
  • [32] Transcatheter aortic valve implantation in a cancer patient denied for surgical aortic valve replacement-a case report
    Mrak, Miha
    Ambrozic, Jana
    Music, Spela
    Terseglav, Simon
    Kontestabile, Bojan
    Lakic, Nikola
    Bunc, Matjaz
    WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 (13-14) : 516 - 520
  • [33] Patient-prosthesis mismatch: surgical aortic valve replacement versus transcatheter aortic valve replacement in high risk patients with aortic stenosis
    Ghanta, Ravi K.
    Kron, Irving L.
    JOURNAL OF THORACIC DISEASE, 2016, 8 (10) : E1441 - E1443
  • [34] Transcatheter Aortic Valve Implantation Compared With Surgical Aortic Valve Replacement in Low-Risk Patients
    Rosato, Stefano
    Santini, Francesco
    Barbanti, Marco
    Biancari, Fausto
    D'Errigo, Paola
    Onorati, Francesco
    Tamburino, Corrado
    Ranucci, Marco
    Covello, Remo Daniel
    Santoro, Gennaro
    Grossi, Claudio
    Ventura, Martina
    Fusco, Danilo
    Seccareccia, Fulvia
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (05)
  • [35] A comparison of neurological event and mortality rates between transcatheter aortic valve implantation and surgical aortic valve replacement
    Yuan, Shi-Min
    Yuan, Ai-Hong
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2023, 19 (03): : 202 - 208
  • [36] Comparison of late mortality after transcatheter aortic valve implantation versus surgical aortic valve replacement: Insights from a meta-analysis
    Ando, Tomo
    Takagi, Hisato
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2017, 40 : 43 - 49
  • [37] Redo Surgical Aortic Valve Replacement After Prior Transcatheter Versus Surgical Aortic Valve Replacement
    Hawkins, Robert B.
    Deeb, G. Michael
    Sukul, Devraj
    Patel, Himanshu J.
    Gualano, Sarah K.
    Chetcuti, Stanley J.
    Grossman, P. Michael
    Ailawadi, Gorav
    Fukuhara, Shinichi
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (08) : 942 - 953
  • [38] Patient-Prosthesis Mismatch After Aortic Valve Intervention Another Win for Transcatheter Aortic Valve Replacement
    Prendergast, Bernard D.
    McConkey, Hannah Z. R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (08) : 781 - 783
  • [39] Transcatheter Aortic Valve Implantation and Replacement: The Latest Advances and Prospects
    Brankovic, Milos
    Sharma, Abhishek
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [40] Right ventricular function following surgical aortic valve replacement and transcatheter aortic valve implantation: A cardiovascular MR study
    Al Musa, Tarique
    Uddin, Akhlaque
    Fairbairn, Timothy A.
    Dobson, Laura E.
    Steadman, Christopher D.
    Kidambi, Ananth
    Ripley, David P.
    Swoboda, Peter P.
    McDiarmid, Adam K.
    Erhayiem, Bara
    Garg, Pankaj
    Blackman, Daniel J.
    Plein, Sven
    McCann, Gerald P.
    Greenwood, John P.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 223 : 639 - 644