Computational simulation of elliptical concrete-filled steel tubular short columns including new confinement model

被引:24
作者
Ahmed, Mizan [1 ,2 ]
Liang, Qing Quan [1 ]
机构
[1] Victoria Univ, Coll Engn & Sci, POB 14428, Melbourne, Vic 8001, Australia
[2] Monash Univ, Dept Civil Engn, Clayton, Vic 8001, Australia
关键词
Concrete-filled steel tubes; Elliptical cross-section; Fiber element modeling; Nonlinear analysis; HIGH-STRENGTH CONCRETE; STRESS-STRAIN MODEL; NONLINEAR-ANALYSIS; HOLLOW SECTIONS; STUB COLUMNS; BEHAVIOR; PERFORMANCE; DESIGN; TESTS;
D O I
10.1016/j.jcsr.2020.106294
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The confinement mechanism in elliptical concrete-filled steel tubular (CFST) columns differs considerably from that in circular or rectangular CFST columns. It is essential to quantify this confinement effect in elliptical CFST columns in order to accurately predict their structural responses. This paper describes a computational model utilizing the method of fiber analysis for the nonlinear simulation of short CFST elliptical columns that are concentrically loaded. Based on available experimental data, a new model of confinement is developed for determining the lateral stresses on the filled concrete in CFST elliptical columns and included in the fiber-based model. A factor of strength degradation is derived that quantifies the post-peak residual strength of concrete. Comparisons with experimental results are made to assess the accuracy of the computer simulation method developed. Investigations into the performance of CFST elliptical columns with important variables are undertaken by using the computer simulation program. An equation is given that determines the capacities of short elliptical CFST columns recognizing concrete confinement. The applicability of the codified methods for CFST columns of rectangular and circular sections to the design of CFST elliptical columns is investigated. It is found that the computer simulation and design models proposed provide accurate predictions of the structural behavior and strength of short elliptical CFST columns loaded concentrically. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 42 条
[1]   Computational simulation of eccentrically loaded circular thin-walled concrete-filled double steel tubular slender columns [J].
Ahmed, Mizan ;
Liang, Qing Quan ;
Patel, Vipulkumar Ishvarbhai ;
Hadi, Muhammad N. S. .
ENGINEERING STRUCTURES, 2020, 213
[2]   Local-global interaction buckling of square high strength concrete-filled double steel tubular slender beam-columns [J].
Ahmed, Mizan ;
Liang, Qing Quan ;
Patel, Vipulkumar Ishvarbhai ;
Hadi, Muhammad N. S. .
THIN-WALLED STRUCTURES, 2019, 143
[3]   Numerical analysis of axially loaded circular high strength concrete-filled double steel tubular short columns [J].
Ahmed, Mizan ;
Liang, Qing Quan ;
Patel, Vipulkumar Ishvarbhai ;
Hadi, Muhammad N. S. .
THIN-WALLED STRUCTURES, 2019, 138 :105-116
[4]   Nonlinear analysis of rectangular concrete-filled double steel tubular short columns incorporating local buckling [J].
Ahmed, Mizan ;
Liang, Qing Quan ;
Patel, Vipulkumar Ishvarbhai ;
Hadi, Muhammad N. S. .
ENGINEERING STRUCTURES, 2018, 175 :13-26
[5]  
AIJ (Architectural Institute of Japan), 1997, Recommendations For Design and Construction of Concrete Filled Steel Tubular Structures
[6]  
[Anonymous], 2004, EN 1994-1-1
[7]  
[Anonymous], 2010, GB509362014 HOUS URB
[8]  
[Anonymous], 2016, AISC 360 16
[9]  
[Anonymous], 2011, 318 ACI
[10]   Experimental and numerical investigation of concrete-filled hot-finished and cold-formed steel elliptical tubular stub columns [J].
Cai, Yancheng ;
Quach, Wai-Meng ;
Young, Ben .
THIN-WALLED STRUCTURES, 2019, 145