In vitro and in vivo evaluation of biodegradable, open-porous scaffolds made of sintered magnesium W4 short fibres.

被引:118
作者
Bobe, K. [1 ]
Willbold, E. [1 ]
Morgenthal, I. [2 ]
Andersen, O. [2 ]
Studnitzky, T. [2 ]
Nellesen, J. [3 ]
Tillmann, W. [3 ]
Vogt, C. [4 ]
Vano, K. [4 ]
Witte, F. [1 ]
机构
[1] Hannover Med Sch, Lab Biomech & Biomat, D-30625 Hannover, Germany
[2] Branch Lab Dresden, Fraunhofer Inst Mfg Technol & Adv Mat IFAM, D-01277 Dresden, Germany
[3] Tech Univ Dortmund, Inst Mat Sci, D-44227 Dortmund, Germany
[4] Leibniz Univ Hannover, Dept Inorgan Chem, D-30167 Hannover, Germany
关键词
Degradable scaffolds; Magnesium alloy; Biodegradable metal; Temporary implant; Open porosity; MECHANICAL-PROPERTIES; ION CHANNELS; CORROSION; MG; IMPLANTS; ALLOYS; DEGRADATION; MODULATION; CALCIUM;
D O I
10.1016/j.actbio.2013.03.035
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A cytocompatible and biocompatible, degradable, open-porous, mechanically adaptable metal scaffold made of magnesium alloy W4 melt-extracted short fibres was fabricated by liquid phase sintering. Cylindrical samples (3 x 5 mm) of sintered W4 short fibres were evaluated under in vitro (L929, HOB, eudiometer, weight loss) and in vivo conditions (rabbits: 6 and 12 weeks). The in vitro corrosion environment (e.g., temperature, flow, composition of corrosion solution, exposure time) significantly influenced the corrosion rates of W4 scaffolds compared with corrosion in vivo. Corrosion rates under cell culture conditions for 72 h varied from 1.05 to 3.43 mm y(-1) depending on the media composition. Corrosion rates measured in eudiometric systems for 24 h were similar to 24-27 times higher (3.88-4.43 mm y(-1)) than corrosion in vivo after 6 weeks (0.16 mm y(-1)). Moreover, it was found that the cell culture media composition significantly influences the ionic composition of the extract by selectively dissolving ions from W4 samples or their corrosion products. A pilot in vivo study for 6 and 12 weeks demonstrated active bone remodelling, no foreign body reaction and no clinical observation of gas formation during W4 scaffold implantation. Long-term in vivo studies need to be conducted to prove complete degradation of the W4 scaffold and total replacement by the host tissue. (C) 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:8611 / 8623
页数:13
相关论文
共 37 条
  • [21] Studnitzky T., 2011, EUR INT POWD MET C E, P345
  • [22] XPS Studies of Magnesium Surfaces after Exposure to Dulbecco's Modified Eagle Medium, Hank's Buffered Salt Solution, and Simulated Body Fluid
    Tie, Di
    Feyerabend, Frank
    Hort, Norbert
    Willumeit, Regine
    Hoeche, Daniel
    [J]. ADVANCED ENGINEERING MATERIALS, 2010, 12 (12) : B699 - B704
  • [23] Processing of biocompatible porous Ti and Mg
    Wen, CE
    Mabuchi, M
    Yamada, Y
    Shimojima, K
    Chino, Y
    Asahina, T
    [J]. SCRIPTA MATERIALIA, 2001, 45 (10) : 1147 - 1153
  • [24] Histology and research at the hard tissue-implant interface using Technovit 9100 New embedding technique
    Willbold, Elmar
    Witte, Frank
    [J]. ACTA BIOMATERIALIA, 2010, 6 (11) : 4447 - 4455
  • [25] Biodegradable magnesium scaffolds: Part II: Peri-implant bone remodeling
    Witte, F.
    Ulrich, H.
    Palm, C.
    Willbold, E.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 81A (03) : 757 - 765
  • [26] Biodegradable magnesium scaffolds: Part I: Appropriate inflammatory response
    Witte, F.
    Ulrich, H.
    Rudert, M.
    Willbold, E.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 81A (03) : 748 - 756
  • [27] Cartilage repair on magnesium scaffolds used as a subchondral bone replacement
    Witte, F.
    Reifenrath, J.
    Mueller, P. P.
    Crostack, H. -A.
    Nellesen, J.
    Bach, F. W.
    Bormann, D.
    Rudert, M.
    [J]. MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2006, 37 (06) : 504 - 508
  • [28] In vivo corrosion of four magnesium alloys and the associated bone response
    Witte, F
    Kaese, V
    Haferkamp, H
    Switzer, E
    Meyer-Lindenberg, A
    Wirth, CJ
    Windhagen, H
    [J]. BIOMATERIALS, 2005, 26 (17) : 3557 - 3563
  • [29] Witte F, 2012, EUR CELL MAT S2, V23, P39
  • [30] The history of biodegradable magnesium implants: A review
    Witte, Frank
    [J]. ACTA BIOMATERIALIA, 2010, 6 (05) : 1680 - 1692