IRISHS, the Infrared Imaging Spatial Heterodyne Spectrometer: a new pushbroom Fourier transform ultraspectral imager with no moving parts

被引:10
|
作者
Smith, BW [1 ]
Laubscher, B [1 ]
Cooke, B [1 ]
LaDelfe, P [1 ]
Harlander, J [1 ]
Howard, JW [1 ]
Milligan, S [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87544 USA
来源
INFRARED TECHNOLOGY AND APPLICATIONS XXV | 1999年 / 3698卷
关键词
imaging spectroscopy; infrared spectroscopy; Fourier transform spectroscopy; remote sensing;
D O I
10.1117/12.354552
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Imaging spatial heterodyne spectroscopy (ISHS) was invented by Roesler and Harlander and applied to the far ultraviolet. It also has advantages for remote sensing applications in the visible and infrared bands. We have designed, assembled, and ground-tested a new instrument designed for eventual airborne or spaceborne deployment for imaging spectroscopy at ultraspectral resolution (1 cm(-1)). IRISHS is a true, imaging, Fourier transform spectrometer (FTS) with a fully open square field of view (no slit), where the third dimension required to assemble data cubes is acquired by scanning the FOV linearly over the scene. Spatially displayed fringes are differenced ("heterodyned") with a spatial frequency determined by a pair of diffraction gratings, giving easily sampled fringe patterns. The current system operates between 8 and 12.5 microns in six sub-bands and employs a 256x256 pixel focal plane array. In comparison to dispersive imaging spectrometers with equivalent resolution, ISHS has: 1) much larger etendue in a small package; 2) full-field imaging for ease in image reconstruction; 3) approximately the same signal-to-noise ratio (S/N) in equivalent observing scenarios, except in the case where the entire dispersive spectrometer is cryogenically cooled. In comparison to conventional FTS, ISHS has: I) no moving parts during data collection; 2) pushbroom imaging, 3) approximately the same SM for equivalent conditions, 4) much lower data rate.
引用
收藏
页码:501 / 509
页数:9
相关论文
共 50 条
  • [31] Method of realizing compact Fourier transform spectrometer without moving parts based on birefringent liquid crystal
    Xia, Liangping
    Yang, Zheng
    Yin, Shaoyun
    Deng, Qiling
    Du, Chunlei
    OPTICAL ENGINEERING, 2014, 53 (07)
  • [32] Silicon nitride on-chip spatial heterodyne Fourier-transform spectrometer with high etendue and broadband operation
    Gonzalez-Andrade, David
    Dinh, Thi Thuy Duong
    Guerber, Sylvain
    Vulliet, Nathalie
    Cremer, Sebastien
    Monfray, Stephane
    Cassan, Eric
    Marris-Morini, Delphine
    Boeuf, Frederic
    Cheben, Pavel
    Vivien, Laurent
    Velasco, Aitor V.
    Alonso-Ramos, Carlos
    2021 IEEE 17TH INTERNATIONAL CONFERENCE ON GROUP IV PHOTONICS (GFP 2021), 2021,
  • [33] Improving Spectral Results Using Row-by-Row Fourier Transform of Spatial Heterodyne Raman Spectrometer Interferogram
    Barnett, Patrick D.
    Strange, K. Alicia
    Angel, S. Michael
    APPLIED SPECTROSCOPY, 2017, 71 (06) : 1380 - 1386
  • [34] Complex-Fourier-transform integrated-optic spatial heterodyne spectrometer using phase shift technique
    Takada, K.
    Aoyagi, H.
    Okamoto, K.
    ELECTRONICS LETTERS, 2010, 46 (24) : 1620 - 1621
  • [35] Design of spatio-temporally modulated static infrared imaging Fourier transform spectrometer
    Liang, Jing Qiu (liangjq@ciomp.ac.cn), 1600, Optical Society of America (OSA) (39):
  • [36] Spectral calibration for infrared hyperspectral imaging Fourier transform spectrometer based on absorption peaks
    Li, YaSheng
    Chen, Yan
    Liao, Ningfang
    Lyu, Hang
    He, Shufang
    Wan, Lifang
    2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2015, 9623
  • [37] Design of spatio-temporally modulated static infrared imaging Fourier transform spectrometer
    Wang, WenCong
    Liang, JingQiu
    Liang, ZhongZhu
    Lu, JinGuang
    Qin, Yuxin
    Tian, Chao
    Wang, WeiBiao
    OPTICS LETTERS, 2014, 39 (16) : 4911 - 4914
  • [38] INFRARED IMAGING FOURIER TRANSFORM SPECTROMETER AS THE STAND-OFF GAS DETECTION SYSTEM
    Kastek, Mariusz
    Piatkowski, Tadeusz
    Trzaskawka, Piotr
    METROLOGY AND MEASUREMENT SYSTEMS, 2011, 18 (04) : 607 - 620
  • [39] The infrared Fourier Transform Spectrometer and the infrared imager instrument concepts for the FORUM mission, ESA's 9th Earth Explorer
    Pachot, Charlotte
    Dominguez, Bernardo Carnicero
    Oetjen, Hilke
    Sierk, Bernd
    Mariani, Flavio
    Riel, Stefanie
    Rodrigues, Goncalo
    Copano, Miguel
    Carou, Asier Martinez
    Palchetti, Luca
    Lippa, Magdalena
    Giaccari, Philippe
    Mastrandrea, Carmine
    Perron, Gaetan
    Keim, Corneli
    Kolm, Manfred-Georg
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXIV, 2020, 11530
  • [40] Field identification and spatial determination of hazardous chemicals by Fourier transform infrared imaging
    Lee, Jae Hwan
    Lee, Jong Min
    Kang, Young Il
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2016, 44 (05) : 504 - 520