摘要
Investigating intracerebral tissue at single cell level has become increasingly important in animal studies and meanwhile found its way into clinical applications. The stability of single unit activity (SUA) to be recorded can be however quite elusive, which -among others- might be caused by the mechanical mismatch of stiff neural implants and soft brain tissue. Unfortunately, the variety of factors influencing signal degradation over time are not perfectly understood yet. One opportunity to determine degradation onsets and possibly identify relevant mechanisms influencing signal stability is impedance spectroscopy of the electrode-brain interface. In particular in view of high-channel count electrode arrays used in neuroscientific research, an impedance spectroscopy analyzer is needed, capable of non-destructively and continuously measuring impedance spectra of a large number of electrodes. The measurement system developed in the current study allows determining the impedance spectra from up to 1024 channels with low uncertainty and an accuracy within a 15%-window over a wide range of impedance values.
引用
收藏
页码:211 / 214
页数:4
相关论文
共 50 条
  • [1] High-channel-count comb filter with a simple structure
    Broadband Optical Network Research Laboratories, Department of Electronics Engineering, Tsinghua University, 100084, Beijing, China
    IEEE/Communications Society; IEEE/Lasers and Electro-Optics Society; Optical Society of America, 1600, 370-372 (2004):
  • [2] High-channel-count comb filter with a simple structure
    Chen, Xiangfei
    Mao, Jin
    Li, Xuhui
    Lin, Zhongqiang
    Xie, Shizhong
    Fan, Chongcheng
    OSA Trends in Optics and Photonics Series, 2004, 95 A : 370 - 372
  • [3] Scalable Intersample Interpolation Architecture for High-channel-count Beamformers
    Tomov, Borislav Georgiev
    Nikolov, Svetoslav Ivanov
    Jensen, Jorgen Arendt
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 381 - 384
  • [4] Novel transducers for high-channel-count neuroelectronic recording interfaces
    Guimera-Brunet, Anton
    Masvidal-Codina, Eduard
    Cisneros-Fernajndez, Jose
    Serra-Graells, Francesc
    Garrido, Jose A.
    CURRENT OPINION IN BIOTECHNOLOGY, 2021, 72 : 39 - 47
  • [5] High-channel-count systems architecture for noise and vibration measurements
    DeFilippo, Chris
    Debelle, Thierry
    Veggeberg, Kurt
    2007 IEEE AUTOTESTCON, VOLS 1 AND 2, 2007, : 583 - 588
  • [6] Optical power meters take on the high-channel-count challenge
    Fischer, H
    PHOTONICS SPECTRA, 2002, 36 (04) : 62 - +
  • [7] Redundant safety features in a high-channel-count retinal neurostimulator
    Kelly, Shawn K.
    Ellersick, William F.
    Krishnan, Ashwati
    Doyle, Patrick
    Shire, Douglas B.
    Wyatt, John L.
    Rizzo, Joseph F.
    2014 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2014, : 216 - 219
  • [8] Advances in the design and fabrication of high-channel-count fiber Bragg gratings
    Li, Hongpu
    Li, Ming
    Sheng, Yunlong
    Rothenberg, Joshua E.
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2007, 25 (09) : 2739 - 2750
  • [9] Effective algorithm for high-channel-count multichannel fiber Bragg grating designs
    Chang, Yuhsin
    Chen, Chyong-Hua
    APPLIED OPTICS, 2012, 51 (25) : 5952 - 5959
  • [10] System Development Improvements using Stackable High-Channel-Count Ultrasound Hardware
    Tobias, Richard J.
    Schafer, Mark E.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 321 - 324