Magnetic spin imaging under ambient conditions with sub-cellular resolution

被引:253
作者
Steinert, S. [1 ,2 ]
Ziem, F. [1 ,2 ]
Hall, L. T. [3 ]
Zappe, A. [1 ,2 ]
Schweikert, M. [4 ]
Goetz, N. [1 ,2 ]
Aird, A. [1 ,2 ]
Balasubramanian, G. [5 ,6 ]
Hollenberg, L. [3 ]
Wrachtrup, J. [1 ,2 ]
机构
[1] Univ Stuttgart, Inst Phys 3, D-70569 Stuttgart, Germany
[2] Univ Stuttgart, Res Ctr SCOPE, D-70569 Stuttgart, Germany
[3] Univ Melbourne, Sch Phys, Ctr Quantum Computat & Commun Technol, Parkville, Vic 3010, Australia
[4] Univ Stuttgart, Inst Biol, D-70569 Stuttgart, Germany
[5] Max Planck Inst Biophys Chem, Res Grp Nanoscale Spin Imaging, D-70377 Gottingen, Germany
[6] Ctr Nanoscale Microscopy & Mol Physiol Brain CNMP, D-70377 Gottingen, Germany
来源
NATURE COMMUNICATIONS | 2013年 / 4卷
基金
澳大利亚研究理事会;
关键词
MICROSCOPY; RESONANCE; DIAMOND; CENTERS; NUCLEAR; MAGNETOMETRY; COMPLEXES; COHERENCE; NOISE; TIME;
D O I
10.1038/ncomms2588
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The detection of small numbers of magnetic spins is a significant challenge in the life, physical and chemical sciences, especially when room temperature operation is required. Here we show that a proximal nitrogen-vacancy spin ensemble serves as a high precision sensing and imaging array. Monitoring its longitudinal relaxation enables sensing of freely diffusing, unperturbed magnetic ions and molecules in a microfluidic device without applying external magnetic fields. Multiplexed charge-coupled device acquisition and an optimized detection scheme permits direct spin noise imaging of magnetically labelled cellular structures under ambient conditions. Within 20 s we achieve spatial resolutions below 500 nm and experimental sensitivities down to 1,000 statistically polarized spins, of which only 32 ions contribute to a net magnetization. The results mark a major step towards versatile subcellular magnetic imaging and real-time spin sensing under physiological conditions providing a minimally invasive tool to monitor ion channels or haemoglobin trafficking inside live cells.
引用
收藏
页数:6
相关论文
共 40 条
[1]   Diamonds with a high density of nitrogen-vacancy centers for magnetometry applications [J].
Acosta, V. M. ;
Bauch, E. ;
Ledbetter, M. P. ;
Santori, C. ;
Fu, K. -M. C. ;
Barclay, P. E. ;
Beausoleil, R. G. ;
Linget, H. ;
Roch, J. F. ;
Treussart, F. ;
Chemerisov, S. ;
Gawlik, W. ;
Budker, D. .
PHYSICAL REVIEW B, 2009, 80 (11)
[2]   Zooming In on Microscopic Flow by Remotely Detected MRI [J].
Bajaj, Vikram S. ;
Paulsen, Jeffrey ;
Harel, Elad ;
Pines, Alexander .
SCIENCE, 2010, 330 (6007) :1078-1081
[3]  
Balasubramanian G, 2009, NAT MATER, V8, P383, DOI [10.1038/nmat2420, 10.1038/NMAT2420]
[4]   Pulsed three-dimensional electron spin resonance microscopy [J].
Blank, A ;
Dunnam, CR ;
Borbat, PP ;
Freed, JH .
APPLIED PHYSICS LETTERS, 2004, 85 (22) :5430-5432
[5]  
BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
[6]   Optical magnetometry [J].
Budker, Dmitry ;
Romalis, Michael .
NATURE PHYSICS, 2007, 3 (04) :227-234
[7]   Small molecular gadolinium(III) complexes as MRI contrast agents for diagnostic imaging [J].
Chan, Kannie Wai-Yan ;
Wong, Wing-Tak .
COORDINATION CHEMISTRY REVIEWS, 2007, 251 (17-20) :2428-2451
[8]   Spin microscope based on optically detected magnetic resonance [J].
Chernobrod, BM ;
Berman, GP .
JOURNAL OF APPLIED PHYSICS, 2005, 97 (01)
[9]  
Clarke J., 2006, The SQUID handbook: Applications of SQUIDs and SQUID systems
[10]   Scanning quantum decoherence microscopy [J].
Cole, Jared H. ;
Hollenberg, Lloyd C. L. .
NANOTECHNOLOGY, 2009, 20 (49)