Magnetic spin imaging under ambient conditions with sub-cellular resolution

被引:247
作者
Steinert, S. [1 ,2 ]
Ziem, F. [1 ,2 ]
Hall, L. T. [3 ]
Zappe, A. [1 ,2 ]
Schweikert, M. [4 ]
Goetz, N. [1 ,2 ]
Aird, A. [1 ,2 ]
Balasubramanian, G. [5 ,6 ]
Hollenberg, L. [3 ]
Wrachtrup, J. [1 ,2 ]
机构
[1] Univ Stuttgart, Inst Phys 3, D-70569 Stuttgart, Germany
[2] Univ Stuttgart, Res Ctr SCOPE, D-70569 Stuttgart, Germany
[3] Univ Melbourne, Sch Phys, Ctr Quantum Computat & Commun Technol, Parkville, Vic 3010, Australia
[4] Univ Stuttgart, Inst Biol, D-70569 Stuttgart, Germany
[5] Max Planck Inst Biophys Chem, Res Grp Nanoscale Spin Imaging, D-70377 Gottingen, Germany
[6] Ctr Nanoscale Microscopy & Mol Physiol Brain CNMP, D-70377 Gottingen, Germany
来源
NATURE COMMUNICATIONS | 2013年 / 4卷
基金
澳大利亚研究理事会;
关键词
MICROSCOPY; RESONANCE; DIAMOND; CENTERS; NUCLEAR; MAGNETOMETRY; COMPLEXES; COHERENCE; NOISE; TIME;
D O I
10.1038/ncomms2588
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The detection of small numbers of magnetic spins is a significant challenge in the life, physical and chemical sciences, especially when room temperature operation is required. Here we show that a proximal nitrogen-vacancy spin ensemble serves as a high precision sensing and imaging array. Monitoring its longitudinal relaxation enables sensing of freely diffusing, unperturbed magnetic ions and molecules in a microfluidic device without applying external magnetic fields. Multiplexed charge-coupled device acquisition and an optimized detection scheme permits direct spin noise imaging of magnetically labelled cellular structures under ambient conditions. Within 20 s we achieve spatial resolutions below 500 nm and experimental sensitivities down to 1,000 statistically polarized spins, of which only 32 ions contribute to a net magnetization. The results mark a major step towards versatile subcellular magnetic imaging and real-time spin sensing under physiological conditions providing a minimally invasive tool to monitor ion channels or haemoglobin trafficking inside live cells.
引用
收藏
页数:6
相关论文
共 40 条
  • [1] Diamonds with a high density of nitrogen-vacancy centers for magnetometry applications
    Acosta, V. M.
    Bauch, E.
    Ledbetter, M. P.
    Santori, C.
    Fu, K. -M. C.
    Barclay, P. E.
    Beausoleil, R. G.
    Linget, H.
    Roch, J. F.
    Treussart, F.
    Chemerisov, S.
    Gawlik, W.
    Budker, D.
    [J]. PHYSICAL REVIEW B, 2009, 80 (11):
  • [2] Zooming In on Microscopic Flow by Remotely Detected MRI
    Bajaj, Vikram S.
    Paulsen, Jeffrey
    Harel, Elad
    Pines, Alexander
    [J]. SCIENCE, 2010, 330 (6007) : 1078 - 1081
  • [3] Balasubramanian G, 2009, NAT MATER, V8, P383, DOI [10.1038/nmat2420, 10.1038/NMAT2420]
  • [4] Pulsed three-dimensional electron spin resonance microscopy
    Blank, A
    Dunnam, CR
    Borbat, PP
    Freed, JH
    [J]. APPLIED PHYSICS LETTERS, 2004, 85 (22) : 5430 - 5432
  • [5] BLOCH F, 1946, PHYS REV, V70, P460, DOI 10.1103/PhysRev.70.460
  • [6] Optical magnetometry
    Budker, Dmitry
    Romalis, Michael
    [J]. NATURE PHYSICS, 2007, 3 (04) : 227 - 234
  • [7] Small molecular gadolinium(III) complexes as MRI contrast agents for diagnostic imaging
    Chan, Kannie Wai-Yan
    Wong, Wing-Tak
    [J]. COORDINATION CHEMISTRY REVIEWS, 2007, 251 (17-20) : 2428 - 2451
  • [8] Spin microscope based on optically detected magnetic resonance
    Chernobrod, BM
    Berman, GP
    [J]. JOURNAL OF APPLIED PHYSICS, 2005, 97 (01)
  • [9] Clarke J., 2006, The SQUID handbook: Applications of SQUIDs and SQUID systems
  • [10] Scanning quantum decoherence microscopy
    Cole, Jared H.
    Hollenberg, Lloyd C. L.
    [J]. NANOTECHNOLOGY, 2009, 20 (49)