Determination of fentanyl in biological and water samples using single-drop liquid-liquid-liquid microextraction coupled with high-performance liquid chromatography

被引:56
作者
Ebrahimzadeh, H. [1 ]
Yamini, Y. [2 ]
Gholizade, A. [1 ]
Sedighi, A. [1 ]
Kasraee, S. [1 ]
机构
[1] Shahid Beheshti Univ, Dept Chem, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
关键词
single-drop liquid-liquid-liquid; microextraction; high-performance liquid; chromatography; fentanyl; plasma; urine; water;
D O I
10.1016/j.aca.2008.07.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single-drop liquid-liquid-liquid microextraction (LLLME) method coupled with high-performance liquid chromatography (HPLC) was developed for the determination of fentanyl in biological (plasma and urine) and wastewater samples. Fentanyl is a potent synthetic narcotic analgesic administered in the form of a transdermal patch for the management of chronic pain. Fentanyl was extracted from 0.01 M NaOH solution (donor phase) into a thin layer of organic phase (100 mu L), then back-extracted into 5 mu L of the acidic acceptor microdrop (1 x 10(-3) M HClO4) immersed in the organic membrane from the tip of a 25-mu L HPLC syringe. After the extraction, the microdrop was withdrawn into the syringe and injected directly into a HPLC system for analysis. The parameters influencing the extraction efficiency including the organic solvent and its volume, acceptor microdrop volume, composition of the donor and acceptor phases, stirring rate, temperature, salt addition and pre- and back-extraction times were investigated and optimized. At the most appropriate conditions (100 CL of n-octane, 3.6 mL of the donor phase maintained at 0.01 M NaOH, 5 mu L of 1 x 10(-3) M HClO4 as the acceptor microdrop, stirring rate of 1000 rpm for pre-extraction and 700 rpm for back-extraction, 30 degrees C, no salt addition, 30 min for pre-extraction and 20 min for back-extraction), an enrichment factor (EF) of 355 was obtained. The limit of detection (LOD) was 0.1 ng mL(-1) (based on S/N = 3) and intra- and inter-day relative standard deviations less than 9% were obtained. The calibration graph was linear within the range of 0.5-1000ng mL(-1) with the correlation coefficient (r) of 0.9999. Finally, the feasibility of the proposed method was evaluated by extraction and determination of fentanyl in plasma, urine and wastewater samples and satisfactory results were obtained. (c) 2008 Published by Elsevier B.V.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 31 条
[1]   Determination of fentanyl in human plasma by head-space solid-phase microextraction and gas chromatography-mass spectrometry [J].
Bagheri, Habib ;
Es-haghi, Ali ;
Khalilian, Faezeh ;
Rouini, Mohammad-Reza .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1763-1768
[2]   FREQUENT HYPOXEMIA AND APNEA AFTER SEDATION WITH MIDAZOLAM AND FENTANYL [J].
BAILEY, PL ;
PACE, NL ;
ASHBURN, MA ;
MOLL, JWB ;
EAST, KA ;
STANLEY, TH .
ANESTHESIOLOGY, 1990, 73 (05) :826-830
[3]   High performance liquid chromatography microassay for the simultaneous determination of fentanyl and its major metabolites in biological samples [J].
Bansal, R ;
Aranda, JV .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (03) :353-364
[4]   Strategies for solvent selection - A literature review [J].
Barwick, VJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (06) :293-309
[5]   PHARMACOKINETICS OF HIGH-DOSE FENTANYL - A STUDY IN PATIENTS UNDERGOING CARDIAC-SURGERY [J].
BOVILL, JG ;
SEBEL, PS .
BRITISH JOURNAL OF ANAESTHESIA, 1980, 52 (08) :795-801
[6]   Quantitative analysis of fentanyl in rat plasma by gas chromatography with nitrogen-phosphorus detection [J].
Choi, HS ;
Shin, HC ;
Khang, G ;
Rhee, JM ;
Lee, HB .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 765 (01) :63-69
[7]   LC-MS/MS analysis of fentanyl and norfentanyl in a fatality due to application of multiple Durogesic® transdermal therapeutic systems [J].
Coopman, Vera ;
Cordonnier, Jan ;
Pien, Karen ;
Van Varenbergh, Dirk .
FORENSIC SCIENCE INTERNATIONAL, 2007, 169 (2-3) :223-227
[8]   Determination of tramadol in human plasma and urine samples using liquid phase microextraction with back extraction combined with high performance liquid chromatography [J].
Ebrahimzadeh, H. ;
Yamini, Y. ;
Sedighi, A. ;
Rouini, M. R. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (02) :229-234
[9]   Determination of subnanogram concentrations of fentanyl in plasma by gas chromatography mass spectrometry: Comparison with standard radioimmunoassay [J].
Fryirsa, B ;
Woodhouse, A ;
Huang, JL ;
Dawson, M ;
Mather, LE .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 688 (01) :79-85
[10]   Use of single-drop microextraction for determination of fentanyl in water samples [J].
Gupta, Pradeep Kumar ;
Manral, Laxmi ;
Ganesan, Kumaran ;
Dubey, Devendra Kumar .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (03) :579-583