Using Hyperpolarized 129Xe MRI to Quantify the Pulmonary Ventilation Distribution

被引:69
|
作者
He, Mu [1 ,2 ]
Driehuys, Bastiaan [1 ,3 ,4 ]
Que, Loretta G. [5 ]
Huang, Yuh-Chin T. [5 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[2] Duke Univ, Dept Elect & Comp Engn, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiol, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[5] Duke Univ, Med Ctr, Dept Med, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
关键词
Asthma; aging; albuterol; REGIONAL FRACTIONAL VENTILATION; INERT-GAS WASHOUT; LUNG CLEARANCE INDEX; HE-3; MRI; CYSTIC-FIBROSIS; COLLATERAL VENTILATION; PERFUSION INEQUALITY; AIRWAY-OBSTRUCTION; HEALTHY-VOLUNTEERS; BREATHING AIR;
D O I
10.1016/j.acra.2016.07.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Ventilation heterogeneity is impossible to detect with spirometry. Alternatively, pulmonary ventilation can be imaged three-dimensionally using inhaled Xe-129 magnetic resonance imaging (MRI). To date, such images have been quantified primarily based on ventilation defects. Here, we introduce a robust means to transform Xe-129 MRI scans such that the underlying ventilation distribution and its heterogeneity can be quantified. Materials and Methods: Quantitative Xe-129 ventilation MRI was conducted in 12 younger (24.7 +/- 5.2 years) and 10 older (62.2 +/- 7.2 years) healthy individuals, as well as in 9 younger (25.9 +/- 6.4 yrs) and 10 older (63.2 +/- 6.1 years) asthmatics. The younger healthy population was used to establish a reference ventilation distribution and thresholds for six intensity bins. These bins were used to display and quantify the ventilation defect region (VDR), the low ventilation region (LVR), and the high ventilation region (HVR). Results: The ventilation distribution in young subjects was roughly Gaussian with a mean and standard deviation of 0.52 0.18, resulting in VDR = 2.1 +/- 1.3%, LVR = 15.6 +/- 5.4%, and HVR = 17.4 +/- 3.1%. Older healthy volunteers exhibited a significantly right skewed distribution (0.46 +/- 0.20, P = 0.034), resulting in significantly increased VDR (7.0 +/- 4.8%, P = 0.008) and LVR (24.5 +/- 11.5%, P = 0.025). In the asthmatics, VDR and LVR increased in the older population, and HVR was significantly reduced (13.5 +/- 4.6% vs 18.9 +/- 4.5%, P = 0.009). Quantitative Xe-129 MRI also revealed altered ventilation heterogeneity in response to albuterol in two asthmatics with normal spirometry. Conclusions: Quantitative Xe-129 MRI provides a robust and objective means to display and quantify the pulmonary ventilation distribution, even in subjects who have airway function impairment not appreciated by spirometry.
引用
收藏
页码:1521 / 1531
页数:11
相关论文
共 50 条
  • [41] Initial feasibility and challenges of hyperpolarized 129Xe MRI in neonates with bronchopulmonary dysplasia
    Stewart, Neil J.
    Higano, Nara S.
    Mukthapuram, Shanmukha
    Willmering, Matthew M.
    Loew, Wolfgang
    West, Michael
    Arnsperger, Anita
    Pratt, Ronald
    Rao, Madhwesha R.
    Schulte, Rolf F.
    Wild, Jim M.
    Woods, Jason C.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2420 - 2431
  • [42] Effect of T1 relaxation on ventilation mapping using hyperpolarized 129Xe multiple breath wash-out imaging
    Morgado, Felipe
    Couch, Marcus J.
    Stirrat, Elaine
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2670 - 2680
  • [43] Translational applications of hyperpolarized 3He and 129Xe
    Walkup, Laura L.
    Woods, Jason C.
    NMR IN BIOMEDICINE, 2014, 27 (12) : 1429 - 1438
  • [44] Small Animal Imaging with Hyperpolarized 129Xe Magnetic Resonance
    Imai, Hirohiko
    Kimura, Atsuomi
    Fujiwara, Hideaki
    ANALYTICAL SCIENCES, 2014, 30 (01) : 157 - 166
  • [45] Diffusion-Weighted Hyperpolarized 129Xe MRI in Healthy Volunteers and Subjects With Chronic Obstructive Pulmonary Disease
    Kaushik, S. Sivaram
    Cleveland, Zackary I.
    Cofer, Gary P.
    Metz, Gregory
    Beaver, Denise
    Nouls, John
    Kraft, Monica
    Auffermann, William
    Wolber, Jan
    McAdams, H. Page
    Driehuys, Bastiaan
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 1155 - 1165
  • [46] Assessment of pulmonary physiological changes caused by aging, cigarette smoking, and COPD with hyperpolarized 129Xe magnetic resonance
    Rao, Qiuchen
    Li, Haidong
    Zhou, Qian
    Zhang, Ming
    Zhao, Xiuchao
    Shi, Lei
    Xie, Junshuai
    Fan, Li
    Han, Yeqing
    Guo, Fumin
    Liu, Shiyuan
    Zhou, Xin
    EUROPEAN RADIOLOGY, 2024, : 7450 - 7459
  • [47] Production of Hyperpolarized 129Xe Using Spin Exchange Optical Pumping
    Kavtanyuk, Vladimir Vladimirovich
    Kim, Wooyoung
    Ando, Yu
    Chebotaryov, Sergey
    Seon, Yonggeun
    Tan, Joshua Artem
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (10) : 1458 - 1465
  • [48] Molecular Sensing with Host Systems for Hyperpolarized 129Xe
    Jayapaul, Jabadurai
    Schroder, Leif
    MOLECULES, 2020, 25 (20):
  • [49] Preclinical hyperpolarized 129Xe MRI: ventilation and T2* mapping in mouse lungs at 7 T using multi-echo flyback UTE
    Niedbalski, Peter J.
    Cochran, Alexander S.
    Akinyi, Teckla G.
    Thomen, Robert P.
    Fugate, Elizabeth M.
    Lindquist, Diana M.
    Pratt, Ronald G.
    Cleveland, Zackary I.
    NMR IN BIOMEDICINE, 2020, 33 (07)
  • [50] Hyperpolarized 129Xe MRI and spectroscopy of gas exchange abnormalities in chronic hypersensitivity pneumonitis
    Wulfeck, Madison Kocher
    Mummy, David G.
    Zhang, Shuo
    Kadi, Diana
    Goins, Stacy
    Swaminathan, Aparna
    Tighe, Robert M.
    Driehuys, Bastiaan
    Mammarappallil, Joseph G.
    RESPIRATORY MEDICINE, 2024, 234