Using Hyperpolarized 129Xe MRI to Quantify the Pulmonary Ventilation Distribution

被引:69
|
作者
He, Mu [1 ,2 ]
Driehuys, Bastiaan [1 ,3 ,4 ]
Que, Loretta G. [5 ]
Huang, Yuh-Chin T. [5 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[2] Duke Univ, Dept Elect & Comp Engn, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiol, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[5] Duke Univ, Med Ctr, Dept Med, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
关键词
Asthma; aging; albuterol; REGIONAL FRACTIONAL VENTILATION; INERT-GAS WASHOUT; LUNG CLEARANCE INDEX; HE-3; MRI; CYSTIC-FIBROSIS; COLLATERAL VENTILATION; PERFUSION INEQUALITY; AIRWAY-OBSTRUCTION; HEALTHY-VOLUNTEERS; BREATHING AIR;
D O I
10.1016/j.acra.2016.07.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Ventilation heterogeneity is impossible to detect with spirometry. Alternatively, pulmonary ventilation can be imaged three-dimensionally using inhaled Xe-129 magnetic resonance imaging (MRI). To date, such images have been quantified primarily based on ventilation defects. Here, we introduce a robust means to transform Xe-129 MRI scans such that the underlying ventilation distribution and its heterogeneity can be quantified. Materials and Methods: Quantitative Xe-129 ventilation MRI was conducted in 12 younger (24.7 +/- 5.2 years) and 10 older (62.2 +/- 7.2 years) healthy individuals, as well as in 9 younger (25.9 +/- 6.4 yrs) and 10 older (63.2 +/- 6.1 years) asthmatics. The younger healthy population was used to establish a reference ventilation distribution and thresholds for six intensity bins. These bins were used to display and quantify the ventilation defect region (VDR), the low ventilation region (LVR), and the high ventilation region (HVR). Results: The ventilation distribution in young subjects was roughly Gaussian with a mean and standard deviation of 0.52 0.18, resulting in VDR = 2.1 +/- 1.3%, LVR = 15.6 +/- 5.4%, and HVR = 17.4 +/- 3.1%. Older healthy volunteers exhibited a significantly right skewed distribution (0.46 +/- 0.20, P = 0.034), resulting in significantly increased VDR (7.0 +/- 4.8%, P = 0.008) and LVR (24.5 +/- 11.5%, P = 0.025). In the asthmatics, VDR and LVR increased in the older population, and HVR was significantly reduced (13.5 +/- 4.6% vs 18.9 +/- 4.5%, P = 0.009). Quantitative Xe-129 MRI also revealed altered ventilation heterogeneity in response to albuterol in two asthmatics with normal spirometry. Conclusions: Quantitative Xe-129 MRI provides a robust and objective means to display and quantify the pulmonary ventilation distribution, even in subjects who have airway function impairment not appreciated by spirometry.
引用
收藏
页码:1521 / 1531
页数:11
相关论文
共 50 条
  • [21] A Comparison of Two Hyperpolarized 129Xe MRI Ventilation Quantification Pipelines: The Effect of Signal to Noise Ratio
    He, Mu
    Zha, Wei
    Tan, Fei
    Rankine, Leith
    Fain, Sean
    Driehuys, Bastiaan
    ACADEMIC RADIOLOGY, 2019, 26 (07) : 949 - 959
  • [22] Hyperpolarized 129Xe Magnetic Resonance Imaging: Tolerability in Healthy Volunteers and Subjects with Pulmonary Disease
    Shukla, Yajur
    Wheatley, Andrew
    Kirby, Miranda
    Svenningsen, Sarah
    Farag, Adam
    Santyr, Giles E.
    Paterson, Nigel A. M.
    McCormack, David G.
    Parraga, Grace
    ACADEMIC RADIOLOGY, 2012, 19 (08) : 941 - 951
  • [23] 129Xe Chemical Shift in Human Blood and Pulmonary Blood Oxygenation Measurement in Humans Using Hyperpolarized 129Xe NMR
    Norquay, Graham
    Leung, General
    Stewart, Neil J.
    Wolber, Jan
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (04) : 1399 - 1408
  • [24] Rapid pulmonary 129Xe ventilation MRI of discharged COVID-19 patients with zigzag sampling
    Fang, Yuan
    Li, Haidong
    Shen, Luyang
    Zhang, Ming
    Luo, Ming
    Li, Hongchuang
    Rao, Qiuchen
    Chen, Qi
    Li, Yecheng
    Li, Zimeng
    Zhao, Xiuchao
    Shi, Lei
    Zhou, Qian
    Han, Yeqing
    Guo, Fumin
    Zhou, Xin
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (03) : 956 - 966
  • [25] 3D MRI of impaired hyperpolarized 129Xe uptake in a rat model of pulmonary fibrosis
    Cleveland, Zackary I.
    Virgincar, Rohan S.
    Qi, Yi
    Robertson, Scott H.
    Degan, Simone
    Driehuys, Bastiaan
    NMR IN BIOMEDICINE, 2014, 27 (12) : 1502 - 1514
  • [26] Chronic Obstructive Pulmonary Disease: Lobar Analysis with Hyperpolarized 129Xe MR Imaging
    Matin, Tahreema N.
    Rahman, Najib
    Nickol, Annabel H.
    Chen, Mitchell
    Xu, Xiaojun
    Stewart, Neil J.
    Doel, Tom
    Grau, Vicente
    Wild, James M.
    Gleeson, Fergus V.
    RADIOLOGY, 2017, 282 (03) : 857 - 868
  • [27] A portable ventilator with integrated physiologic monitoring for hyperpolarized 129Xe MRI in rodents
    Virgincar, Rohan S.
    Dahlke, Jerry
    Robertson, Scott H.
    Morand, Nathann
    Qi, Yi
    Degan, Simone
    Driehuys, Bastiaan
    Nouls, John C.
    JOURNAL OF MAGNETIC RESONANCE, 2018, 295 : 63 - 71
  • [28] Lung Morphometry Using Hyperpolarized 129Xe Apparent Diffusion Coefficient Anisotropy in Chronic Obstructive Pulmonary Disease
    Ouriadov, Alexei
    Farag, Adam
    Kirby, Miranda
    McCormack, David G.
    Parraga, Grace
    Santyr, Giles E.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1699 - 1706
  • [29] Review of Hyperpolarized Pulmonary Functional 129Xe MR for Long-COVID
    Wild, Jim M.
    Gleeson, Fergus V.
    Svenningsen, Sarah
    Grist, James T.
    Saunders, Laura C.
    Collier, Guilhem J.
    Sharma, Maksym
    Tcherner, Sam
    Mozaffaripour, Ali
    Matheson, Alexander M.
    Parraga, Grace
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (04) : 1120 - 1134
  • [30] Repeatability of regional pulmonary functional metrics of Hyperpolarized 129Xe dissolved-phase MRI
    Hahn, Andrew D.
    Kammerman, Jeff
    Evans, Michael
    Zha, Wei
    Cadman, Robert, V
    Meyer, Keith
    Sandbo, Nathan
    Fain, Sean B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (04) : 1182 - 1190