Application of Superconducting Fault Current Limiter to cloud the presence of Distributed Generation

被引:0
|
作者
Manigilla, Pradeep Kumar Reddy [1 ]
Sharma, Nikhil Kumar [1 ]
Samantaray, S. R. [1 ]
机构
[1] Indian Inst Technol, Sch Elect Sci, Bhubaneswar, Odisha, India
来源
2017 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC) | 2017年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Increase in power demand calls for increase in number of generating stations and interconnections. Microgrid is a novel architecture that utilizes renewable energy resources to meet this increase in power demand. In a Microgrid, power generation is distributed among various small units called Distributed generators (DGs). When a DG is integrated, it causes few protection issues like increase in fault current levels and under reaching of over current relays. Fault current limiters can be used to limit increased fault currents. Under reaching of over current relays can be avoided using adaptive relaying techniques but to implement these methods present relays have to be replaced. Placing a Superconducting Fault Current (SFCL) in series with DG reduces increased fault levels and also avoids under reaching of over current relays. A SFCL in series with DG can reduce the impact of DG on protection equipment. Thus a SFCL can cloud the presence of DG without the need for changing entire protection system.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] The application of the first and second generation superconducting wires for superconducting fault current limiter construction
    Majka, Michal
    Kozak, Slawomir
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (05): : 183 - 185
  • [2] Impact of Resistive Superconducting Fault Current Limiter and Distributed Generation on Fault Location in Distribution Networks
    Guillen, Daniel
    Salas, Christian
    Trillaud, Frederic
    Castro, Luis M.
    Tiago Queiroz, Andre
    Goncalves Sotelo, Guilherme
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 186
  • [3] APPLICATION OF SUPERCONDUCTING FILMS TO FAULT CURRENT LIMITER
    TERASHIMA, Y
    YAMAZAKI, M
    KUDO, Y
    YOSHINO, H
    ANDO, K
    OSHIMA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1994, 33 (11B): : L1592 - L1594
  • [4] Fault Current Limiter Allocation and Sizing in Distribution System in Presence of Distributed Generation
    Shahriari, S. A. A.
    Yazdian, A.
    Haghifam, M. R.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 4221 - 4226
  • [5] A study of the Superconducting Fault Current Limiter application in a MV network with distributed energy sources
    Kempski, Adam
    Rusinski, Jacek
    2017 PROGRESS IN APPLIED ELECTRICAL ENGINEERING (PAEE), 2017,
  • [6] Superconducting Fault Current Limiter for Smart Grid Application
    Reddy, Julakanti Satheesh
    Chatterjee, Soumesh
    PROCEEDINGS OF THE 2017 IEEE SECOND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION TECHNOLOGIES (ICECCT), 2017,
  • [7] Analysis of Impacts of Superconducting Fault Current Limiter (SFCL) Placement on Distributed Generation (DG) Expansion
    Kim, Youngwook
    Jo, Hyung-Chul
    Joo, Sung-Kwan
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (04)
  • [8] Application of Fault Current Limiter to Limit Distributed Generation Effect on Distance Relay Coordination
    Sirsi, Rohan
    Dasarathan, Sattianadan
    2014 Annual IEEE India Conference (INDICON), 2014,
  • [9] Optimal placement and sizing of hybrid superconducting fault current limiter for protection coordination restoration of the distribution networks in the presence of simultaneous distributed generation
    Sadeghi, Mohsen
    Abasi, Mahyar
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 201
  • [10] Impact of superconducting fault current limiter on the distributed energy source work
    Rusinski, Jacek
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (02) : 310 - 317