Comparison of invasive versus noninvasive blood pressure measurements before and after hemorrhage in anesthetized greyhounds using the Surgivet V9203

被引:28
作者
Drynan, Eleanor A. [1 ]
Raisis, Anthea L. [1 ]
机构
[1] Murdoch Univ, Dept Anaesthesia, Sch Vet & Biomed Sci, Murdoch, WA 6150, Australia
关键词
hypotension; hypertension; hypovolemia; MAP; HIGH-DEFINITION OSCILLOMETRY; DOGS; MONITOR; CATS; HYPERTENSION; ANESTHESIA;
D O I
10.1111/vec.12075
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo determine the agreement between blood pressure obtained with a noninvasive technique and direct technique using the Surgivet V9203 at varying blood pressure levels created using a canine hemorrhage model. DesignExperimental study. SettingUniversity Teaching Hospital. AnimalsTwenty-nine greyhounds with an average weight of 30 kg. Approval from the Murdoch University Animal Ethics Committee was obtained (R228609). MethodsArterial blood pressure (BP) was measured noninvasively (NIBP) via a cuff placed over the dorsal metatarsal artery and via a catheter in the contralateral dorsal metatarsal artery (IBP). Retrospectively the blood pressure measurements recorded were divided into various BP categories. A total of 84 paired readings were obtained. The data were further analyzed with respect to heart rate [<120/min and >120/min]. Comparison of the measurements was performed using the Bland-Altman method. ResultsFor all categories, BP measurements were generally lower when recorded using the oscillometric technique [Systolic (Sys) bias 4.20 kPa (31.54 mm Hg), mean bias 0.52 kPa (3.93 mm Hg), and diastolic bias 1.04 kPa (7.83 mm Hg)]. Mean arterial BP had the least bias and greatest precision in the hypotensive group (bias 0.174 kPa (1.3063 mm Hg), precision 0.79 kPa (5.89 mm Hg)), low BP group (bias 0.62 kPa (4.67mm Hg) and precision 0.89 kPa (6.67mm Hg)) and normotensive group [bias 0.76 kPa (5.71 mm Hg) and precision 1.16 kPa (8.73 mmHg)]. ConclusionsThe results demonstrate that the agreement between NIBP measurements and IBP, are within the limits of agreement recommended by the American College of Veterinary Internal Medicine Hypertension Consensus Panel for all pressures except Sys BP. This suggests that mean and diastolic NIBP using the Surgivet V9203 are a clinically acceptable alternative of IBP in hypovolemic hypotensive dogs.
引用
收藏
页码:523 / 531
页数:9
相关论文
共 25 条
[1]  
[Anonymous], J ROY STAT SOC D STA, DOI DOI 10.2307/2987937
[2]   DOPPLER ULTRASONOGRAPHIC, OSCILLOMETRIC SPHYGMOMANOMETRIC, AND PHOTOPLETHYSMOGRAPHIC TECHNIQUES FOR NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN ANESTHETIZED CATS [J].
BINNS, SH ;
SISSON, DD ;
BUOSCIO, DA ;
SCHAEFFER, DJ .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 1995, 9 (06) :405-414
[3]   A COMPARISON OF DIRECT AND INDIRECT (OSCILLOMETRIC) MEASUREMENTS OF ARTERIAL BLOOD-PRESSURE IN ANESTHETIZED DOGS, USING TAIL AND LIMB CUFFS [J].
BODEY, AR ;
YOUNG, LE ;
BARTRAM, DH ;
DIAMOND, MJ ;
MICHELL, AR .
RESEARCH IN VETERINARY SCIENCE, 1994, 57 (03) :265-269
[4]  
Brown S, 2007, J VET INTERN MED, V21, P542, DOI 10.1892/0891-6640(2007)21[542:GFTIEA]2.0.CO
[5]  
2
[6]   Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs [J].
Deflandre, Catherine Ja ;
Hellebrekers, Ludo J. .
VETERINARY ANAESTHESIA AND ANALGESIA, 2008, 35 (01) :13-21
[7]  
Dorsch J, 2007, UNDERSTANDING ANAEST
[8]  
GAINS MJ, 1995, CAN J VET RES, V59, P238
[9]   Complications and mortality associated with anesthesia in dogs and cats [J].
Gaynor, JS ;
Dunlop, CI ;
Wagner, AE ;
Wertz, EM ;
Golden, AE .
JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 1999, 35 (01) :13-17
[10]  
Grosenbaugh DA, 1998, VET MED-US, V93, P48