Changes in aortic shape and diameters after death: Comparison of early postmortem computed tomography with antemortem computed tomography

被引:23
|
作者
Takahashi, Naoya [1 ]
Higuchi, Takeshi [1 ]
Hirose, Yasuo [2 ]
Yamanouchi, Haruo [3 ]
Takatsuka, Hisakazu [3 ]
Funayama, Kazuhisa [3 ]
机构
[1] Niigata City Gen Hosp, Dept Diagnost Radiol, Niigata 9501197, Japan
[2] Niigata City Gen Hosp, Dept Emergency & Crit Care, Niigata 9501197, Japan
[3] Niigata Univ, Dept Community Prevent Med, Div Legal Med, Grad Sch Med & Dent Sci, Niigata, Japan
关键词
Forensic imaging; Postmortem computed tomography; Postmortem change; Aorta; Computed tomography; Autopsy imaging; QUANTITATIVE-ANALYSIS; AUTOPSY; AGE; MRI; MDCT; CT;
D O I
10.1016/j.forsciint.2012.04.037
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Purpose: The purpose of this study is to evaluate the postmortem deformation of the aorta on postmortem computed tomography (CT) by comparison with the antemortem CT in the same patient. Materials and methods: A total of 58 non-traumatic patients without hemorrhagic events who underwent torso CT before and shortly after death were enrolled. Antemortem chest and abdominal CT were obtained in 44 cases and in 57 cases, respectively. The lengths of the major and minor axes of the ascending and descending thoracic aorta and the abdominal aorta were measured on both antemortem and postmortem CT in the same patient. To evaluate the shape of the aorta, the major axis-minor axis ratio (Ma-MiR) was calculated. Mean values of the diameters of the aorta and Ma-MiRs on postmortem CT were compared with those on antemortem CT using the Wilcoxon signed-rank test. We also evaluated the major and minor axes and Ma-MiRs on both antemortem and postmortem CT in two age groups: 65 years and under (n = 13) and over 65 years (n = 45). Results: At each level tested, the aorta significantly shrank after death (p < 0.001) (ascending thoracic aorta, descending thoracic aorta, and abdominal aorta: 38.5 mm x 33.5 mm, 28.0 mm x 25.9 mm, and 24.4 mm x 21.8 mm on antemortem CT, 30.0 mm x 26.2 mm, 24.4 mm x 20.7 mm, and 21.5 mm x 14.5 mm on postmortem CT, respectively). The postmortem Ma-MiRs significantly increased at the descending thoracic aorta and the abdominal aorta (p < 0.001). The diameters of the aorta are longer in older cases at all levels on both antemortem and postmortem CT. The reduction rates were larger in younger cases than older cases at all levels. Conclusions: After death, the aorta shrunk at all levels, and became oval in shape in descending thoracic and abdominal aorta. The contraction was greater in younger cases than older cases. Investigators who interpret postmortem imaging should be aware of the postmortem deformation of the aorta. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 50 条
  • [31] Postmortem computed tomography lung findings in fatal of hypothermia
    Hyodoh, Hideki
    Watanabe, Satoshi
    Katada, Ryuichi
    Hyodoh, Kazusa
    Matsumoto, Hiroshi
    FORENSIC SCIENCE INTERNATIONAL, 2013, 231 (1-3) : 190 - 194
  • [32] The Role of Postmortem Computed Tomography in the Evaluation of Strangulation Deaths
    Decker, Lauren A.
    Hatch, Gary M.
    Lathrop, Sarah L.
    Nolte, Kurt B.
    JOURNAL OF FORENSIC SCIENCES, 2018, 63 (05) : 1401 - 1405
  • [33] Postmortem computed tomography findings in the thorax - Experimental evaluation
    Hyodoh, Hideki
    Shimizu, Jyunya
    Rokukawa, Masumi
    Okazaki, Shunichiro
    Mizuo, Keisuke
    Watanabe, Satoshi
    LEGAL MEDICINE, 2016, 19 : 96 - 100
  • [34] Use of Postmortem Computed Tomography to Detect Bowel Obstruction and its Relationship to the Cause of Death
    Gascho, Dominic
    Schaerli, Sarah
    Tuchtan-Torrents, Lucile
    Thali, Michael J.
    Gorincour, Guillaume
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2018, 39 (01) : 30 - 37
  • [35] Approaching pulmonary fat embolism on postmortem computed tomography
    Vasiliki Chatzaraki
    Jakob Heimer
    Michael J. Thali
    Garyfalia Ampanozi
    Wolf Schweitzer
    International Journal of Legal Medicine, 2019, 133 : 1879 - 1887
  • [36] A comparison of aortic root measurements by echocardiography and computed tomography
    Plonek, Tomasz
    Berezowski, Mikolaj
    Bochenek, Maciej
    Filip, Grzegorz
    Rylski, Bartosz
    Golesworthy, Tal
    Jasinski, Marek
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (02) : 479 - 486
  • [37] Evaluation of normal abdominal aortic diameters in the Indian population using computed tomography
    Jasper, A.
    Harshe, G.
    Keshava, S. N.
    Kulkarni, G.
    Stephen, E.
    Agarwal, S.
    JOURNAL OF POSTGRADUATE MEDICINE, 2014, 60 (01) : 57 - 60
  • [38] Quantitative analysis of vascular signs on early postmortem multi-detector computed tomography
    Torimoto, Izumi
    Takebayashi, Shigeo
    Sekikawa, Zenjiro
    Nishimiya, Noriko
    Morimura, Naoto
    Inoue, Tomio
    SPRINGERPLUS, 2014, 3 : 1 - 12
  • [39] Validation of intravascular ultrasound for measurement of aortic diameters: Comparison with multi-detector computed tomography
    Janosi, Rolf Alexander
    Gorla, Riccardo
    Rogmann, Kim
    Kahlert, Philipp
    Tsagakis, Konstantinos
    Dohle, Daniel-Sebastian
    Wendt, Daniel
    Jakob, Heinz
    Schlosser, Thomas
    Bossone, Eduardo
    Erbel, Raimund
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2015, 24 (05) : 289 - 295
  • [40] Hereditary Angioedema as the Cause of Death from Asphyxia: Postmortem Computed Tomography Study
    Shibuya, Michiko
    Takahashi, Naoya
    Yabe, Masahiro
    Iwamoto, Kazumasa
    Hide, Michihiro
    ALLERGOLOGY INTERNATIONAL, 2014, 63 (03) : 493 - 494