Probing Defects in a Small Pixellated CdTe Sensor Using an Inclined Mono Energetic X-Ray Micro Beam

被引:5
|
作者
Froejdh, Erik [1 ,2 ]
Froejdh, C. [1 ]
Gimenez, E. N. [4 ]
Krapohl, D. [1 ]
Maneuski, D. [3 ]
Norlin, B. [1 ]
O'Shea, V. [3 ]
Wilhelm, H. [4 ]
Tartoni, N. [4 ]
Thungstroem, G. [1 ]
Zain, R. M. [3 ]
机构
[1] Mid Sweden Univ, S-85170 Sundsvall, Sweden
[2] CERN, CH-1211 Geneva 23, Switzerland
[3] Univ Glasgow, Glasgow G12 8QQ, Lanark, Scotland
[4] Diamond Light Source, Didcot OX11 0QX, Oxon, England
关键词
CdTe; CdTe characterization; CdTe detectors; charge collection; charge sharing; charge trapping; defect characterization; defects; detectors; photon counting; radiation detectors; X-ray detectors; X-rays; DETECTORS; SPECTROSCOPY; PERFORMANCE; MEDIPIX2; TIMEPIX; GROWTH; GAAS;
D O I
10.1109/TNS.2013.2257851
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High quantum efficiency is important in X-ray imaging applications. This means using high-Z sensor materials. Unfortunately many of these materials suffer from defects that cause non-ideal charge transport. In order to increase the understanding of these defects, we have mapped the 3D response of a number of defects in two 1 mm thick CdTe sensors with different pixel sizes (55 mu m and 110 mu m) using a monoenergetic microbeam at 79 keV. The sensors were bump bonded to Timepix read out chips. Data was collected in photon counting as well as time-over-thresholdmode. The time-over-thresholdmode is a very powerful tool to investigate charge transport properties and fluorescence in pixellated detectors since the signal from the charge that each photon deposits in each pixel can be analyzed. Results show distorted electrical field around the defects, indications of excess leakage current and large differences in behavior between electron collection and hole collection mode. The experiments were carried out on the Extreme Conditions Beamline I15 at Diamond Light Source.
引用
收藏
页码:2864 / 2869
页数:6
相关论文
共 50 条
  • [1] Probing Defects In a Small Pixellated CdTe Sensor Using an Inclined Mono Energetic X-Ray Micro Beam
    Frojdh, Erik
    Frojdh, C.
    Gimenez, E. N.
    Krapoh
    Maneuski, D.
    Norlin, B.
    O'Shea, V.
    Wilhem, H.
    Tartoni, N.
    Thungstrom, G.
    Zain, R. M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4233 - 4236
  • [2] X-ray micro-beam characterization of a small pixel spectroscopic CdTe detector
    Veale, M. C.
    Bell, S. J.
    Seller, P.
    Wilson, M. D.
    Kachkanov, V.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [3] Energy-windowed, pixellated X-ray diffraction using the Pixirad CdTe detector
    O'Flynn, D.
    Bellazzini, R.
    Minuti, M.
    Brez, A.
    Pinchera, M.
    Spandre, G.
    Moss, R.
    Speller, R. D.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [4] Characterisation of edgeless technologies for pixellated and strip silicon detectors with a micro-focused X-ray beam
    Bates, R.
    Blue, A.
    Christophersen, M.
    Eklund, L.
    Ely, S.
    Fadeyev, V.
    Gimenez, E.
    Kachkanov, V.
    Kalliopuska, J.
    Macchiolo, A.
    Maneuski, D.
    Phlips, B. F.
    Sadrozinski, H. F. -W.
    Stewart, G.
    Tartoni, N.
    Zain, R. M.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [5] Mapping the X-ray response of a CdTe sensor with small pixels using an X-ray microbeam and a single photon processing readout chip
    Frojdh, Erik
    Frojdh, Christer
    Norlin, Borje
    Thungstrom, Goran
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIII, 2011, 8142
  • [6] Materials identification using a small-scale pixellated x-ray diffraction system
    O'Flynn, D.
    Crews, C.
    Drakos, I.
    Christodoulou, C.
    Wilson, M. D.
    Veale, M. C.
    Seller, P.
    Speller, R. D.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2016, 49 (17)
  • [7] CdTe x-ray image sensor using a field emitter array
    Nakagawa, Masashi
    Hanawa, Yuichiro
    Sakata, Takuya
    Morii, Hisashi
    Nagao, Masayoshi
    Yoshida, Tomoya
    Kanemaru, Seigo
    Neo, Yoichiro
    Aoki, Toru
    Mimura, Hidenori
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2009, 27 (02): : 725 - 728
  • [8] Direct microfabrication using an X-ray micro-beam
    Katoh, T
    Zhang, YP
    Kagoshima, Y
    Tsusaka, Y
    Matsui, J
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 97-8 : 725 - 728
  • [9] X-ray micro radiography using beam hardening correction
    Vavrik, Daniel
    Holy, Tomas
    Jakubek, Jan
    Pospisil, Stanislav
    Vykydal, Zdenek
    Dammer, Jiri
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2989 - 2992
  • [10] Direct microfabrication using an X-ray micro-beam
    Katoh, T
    Zhang, YP
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 1578 - 1581