Continuous hemodynamic monitoring during laparoscopic gastric bypass in superobese patients by pressure recording analytical method

被引:19
|
作者
Balderi, Tania [2 ]
Forfori, Francesco [1 ,2 ]
Marra, Valeria [2 ]
Di Salvo, Claudio [2 ]
Dorigo, Massimo [2 ]
Anselmino, Marco [3 ]
Romano, Salvatore Mario [4 ]
Giunta, Francesco [2 ]
机构
[1] Azienda Osped Univ Pisana, Anestesia & Rianimaz Univ 4, Pisa, Italy
[2] Univ Pisa, Dept Surg, Div Anesthesiol & Intens Care, Pisa, Italy
[3] Azienda Osped Pisana, Bariatr Surg Unit, Pisa, Italy
[4] Univ Florence, Unit Internal Med & Cardiol, Dept Crit Care Med, Florence, Italy
关键词
morbid obesity; laparoscopic gastric bypass; pneumoperitoneum; pulse contour analysis; pressure recording analytical method;
D O I
10.1007/s11695-007-9379-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Morbid obesity, compromising cardiovascular and respiratory function, may increase the risk of anesthesia and was initially considered a contraindication to laparoscopy. The aim of this study was to investigate hemodynamic effects induced by pneumoperitoneum in superobese patients, assessed by arterial pulse contour method. Methods We prospectively studied 10 obese patients (BMI 53 +/- 9 kg/m(2)), scheduled for laparoscopic gastric bypass. After anesthesia induction, patients were intubated and mechanically ventilated. A radial artery was cannulated to obtain hemodynamic data implemented by means of a new pulse contour analysis method-the pressure recording analytical method (PRAM). Data were recorded after anesthesia induction (Tbas), at peritoneal insufflation (T0), at 1, 3, 5, 10, 30, and 60 min after pneumoperitoneurn induction (T1, T3, T5, T10, T15, T30, T60), at abdominal desufflation (Tdef) and 5 min after desufflation (T5def). Results MAP increased after pneumoperitoneum, returning to its baseline after deflation (79 +/- 7 Tbas, 81 +/- 6 mmHg T5def). HR remained unchanged. Systemic vascular resistance index (SVRI) increased after pneumoperitoneum induction and progressively returned to baseline (3,903 +/- 330 Tbas, 4,596 +/- 148 T1, and 3,786 +/- 202 dyn s m(2) cm(-5) T5def). Stroke volume index (SVI) and cardiac index (CI) increased after pneumoperitoneurn and remained elevated. Stroke volume variation (SVV) decreased after insufflation remaining lower than the basal value (28 +/- 4% Tbas, 15 +/- 5% T5des). Cardiac Cycle Efficiency (CCE) transient decreased after insufflation and subsequently increased (0.029 +/- 0.146 Tbas, 0.008 +/- 0.178 T5def). Aortic dP/dt max increased after insufflation, returning to baseline only after desufflation (0.68 +/- 0.07 Tbas, 0.94 +/- 0.08 T30 and 0.86 +/- 0.06 mmHg s(-1) T5def). Conclusion As assessed by PRAM, this study showed no deterioration in hemodynamic indices or ventricular performance during laparoscopic gastric bypass.
引用
收藏
页码:1007 / 1014
页数:8
相关论文
共 50 条
  • [41] VALIDATION OF A METHOD OF CONTINUOUS NONINVASIVE MONITORING OF BLOOD-PRESSURE DURING POSITIVE PRESSURE BREATHING IN MAN
    GRADWELL, DP
    JOURNAL OF PHYSIOLOGY-LONDON, 1991, 438 : P170 - P170
  • [42] Glycemic Profile Assessment Using Continuous Glucose Monitoring in Patients With and Without Hypoglycemia After Gastric Bypass Surgery
    Chuang, Janet
    Baum, Leslie
    D'Alessio, David
    Salehi, Marzieh
    DIABETES, 2012, 61 : A215 - A215
  • [43] Continuous glucose monitoring in patients with remission of type 2 diabetes after laparoscopic sleeve gastrectomy without or with duodenojejunal bypass
    Sawada, Shojiro
    Kodama, Shinjiro
    Tsuchiya, Satoko
    Kurosawa, Satoko
    Endo, Akira
    Sugawara, Hiroto
    Hosaka, Shinichiro
    Kawana, Yohei
    Asai, Yoichiro
    Yamamoto, Junpei
    Munakata, Yuichiro
    Izumi, Tomohito
    Takahashi, Kei
    Kaneko, Keizo
    Imai, Junta
    Imoto, Hirofumi
    Tanaka, Naoki
    Naitoh, Takeshi
    Ishigaki, Yasushi
    Katagiri, Hideki
    CLINICAL OBESITY, 2020, 10 (06)
  • [44] Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy
    Sakai, Yoko
    Tsutsumi, Yasuo M.
    Oyama, Takuro
    Murakami, Chiaki
    Kakuta, Nami
    Tanaka, Katsuya
    JOURNAL OF MEDICAL INVESTIGATION, 2018, 65 (1-2): : 69 - 73
  • [45] Goal-directed fluid and hemodynamic therapy in major colon surgery with the pressure recording analytical method cardiac output monitor (MostCare®-PRAM®): prospective analysis of 58 patients
    JM Alonso-Iñigo
    MJ Fas
    V Osca
    A Nacher
    JE Llopis
    Critical Care, 16 (Suppl 1):
  • [46] The Impact of Roux-en-Y Gastric Bypass on Continuous Glucose Monitoring in Mildly Obese Asian Patients with Diabetes
    Yeoh, Ester
    Tan, Chun Hai
    Mishra, Nitish
    Thazin, Ma
    Lam, Benjamin
    Wong, Michael
    Tan, Bernice
    Lim, Boon Khim
    Lim, Su Chi
    Tavintharan, Subramaniam
    Sum, Chee Fang
    Cheng, Anton
    DIABETES, 2016, 65 : A507 - A507
  • [47] CONTINUOUS ARTERIAL-PRESSURE MONITORING DURING MAGNETIC-RESONANCE-IMAGING - AN ALTERNATIVE METHOD
    EMMONS, SW
    MARTIN, HB
    ANESTHESIA AND ANALGESIA, 1992, 74 (02): : 315 - 316
  • [48] Continuous monitoring of gastric intraluminal carbon dioxide pressure, cardiac output, and end-tidal carbon dioxide pressure in the perioperative period in patients receiving cardiovascular surgery using cardiopulmonary bypass
    Imai, T
    Sekiguchi, T
    Nagai, Y
    Morimoto, T
    Nosaka, T
    Mitaka, C
    Makita, K
    Sunamori, M
    CRITICAL CARE MEDICINE, 2002, 30 (01) : 44 - 51
  • [49] Article reviewed: A simplified method for monitoring respiratory impedance during continuous positive airway pressure
    Sanders, Mark H.
    SLEEP MEDICINE, 2000, 1 (04) : 319 - 320
  • [50] Continuous monitoring of advanced hemodynamic parameters during hemodialysis demonstrated early variations in patients experiencing intradialytic hypotension
    Nachman, D. Dean
    Gork, I.
    Amitay, S.
    Moshel, P.
    Goldstein, N.
    Fons, M.
    Tabi, M.
    Eizenkraft, A.
    Elhalel, M. Dranitzki
    Kolben, Y.
    EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 310 - 311