Improved haemodynamics and restoration of spontaneous circulation with constant aortic occlusion during experimental cardiopulmonary resuscitation

被引:49
|
作者
Gedeborg, R [1 ]
Rubertsson, S [1 ]
Wiklund, L [1 ]
机构
[1] Univ Uppsala Hosp, Dept Surg Sci Anaesthesiol & Intens Care, S-75185 Uppsala, Sweden
关键词
cardiopulmonary resuscitation; aortic occlusion; cardiac output; myocardial blood flow; return of spontaneous circulation;
D O I
10.1016/S0300-9572(99)00021-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Continuous balloon occlusion of the descending aorta is an experimental method that may improve blood flow to the myocardium and the brain during cardiopulmonary resuscitation (CPR). The aim of the present investigation was to evaluate the effects of this intervention on haemodynamics and the frequency of restoration of spontaneous circulation. Ventricular fibrillation was induced in 39 anaesthetised piglets, followed by an 8-min non-intervention interval. In a haemodynamic study (n = 10), closed chest CPR was performed for 7 min before the intra-aortic balloon was inflated. This intervention increased mean arterial blood pressure by 20%. reduced cardiac output by 33%, increased coronary artery blood flow by 86%, and increased common carotid artery blood flow by 62%. All these changes were statistically significant. Administration of epinephrine further increased mean arterial blood pressure and coronary artery blood flow, while cardiac output and common carotid artery blood flow decreased. In a study of short-term survival, nine out of 13 animals (69%) in the balloon group and in three out of 13 animals (23%) in the control group had spontaneous circulation restored. The difference between these two proportions was 0.46, which was statistically significant with a 95% confidence interval from 0.12 to 0.80. In conclusion, balloon occlusion of the descending aorta increased coronary and common carotid artery blood dow and the frequency of restoration of spontaneous circulation. II was also noted that epinephrine appears to augment the redistribution of blood flow caused by the aortic occlusion. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:171 / 180
页数:10
相关论文
共 50 条
  • [41] The combination of chest compression synchronized ventilation and aortic balloon occlusion improve the outcomes of cardiopulmonary resuscitation in swine
    Xu, Jiefeng
    Khan, Zafar Ullah
    Zhang, Minhai
    Wang, Jiangang
    Zhou, Meiya
    Zheng, Zhongjun
    Chen, Qijiang
    Zhou, Guangju
    Zhang, Mao
    FRONTIERS IN MEDICINE, 2022, 9
  • [42] Spontaneous return of circulation after termination of cardiopulmonary resuscitation maneuvers: a systematic review of cases of Lazarus phenomenon
    Ballesteros Pena, Sendoa
    Fernandez Aedo, Irrintzi
    Lorrio Palomino, Sergio
    EMERGENCIAS, 2014, 26 (04): : 307 - 316
  • [43] Argon Ventilation Improves Circulation During Cardiopulmonary Resuscitation in a Porcine Model of Cardiac Arrest
    Balzer, Claudius
    Douglas, Hunter F.
    Shekar, Kadambari Chandra
    Salzman, Michele M.
    Yannopoulos, Demetris
    Aufderheide, Tom P.
    Riess, Matthias L.
    CIRCULATION, 2017, 136
  • [44] Differences in the pharmacodynamics of epinephrine and vasopressin during and after experimental cardiopulmonary resuscitation
    Nozari, A
    Rubertsson, S
    Wiklund, L
    RESUSCITATION, 2001, 49 (01) : 59 - 72
  • [45] Cardiopulmonary Resuscitation Without Aortic Valve Compression Increases the Chances of Return of Spontaneous Circulation in Out-of-Hospital Cardiac Arrest: A Prospective Observational Cohort Study
    Chu, Sheng-En
    Huang, Chun-Yen
    Cheng, Chiao-Yin
    Chan, Chun-Hsiang
    Chen, Hsuan-An
    Chang, Chin-Ho
    Tsai, Kuang-Chau
    Chiu, Kuan-Ming
    Ma, Matthew Huei-Ming
    Chiang, Wen-Chu
    Sun, Jen-Tang
    CRITICAL CARE MEDICINE, 2024, 52 (09) : 1367 - 1379
  • [46] Faster Time to Elevation of the Head and Thorax During Cardiopulmonary Resuscitation Increases the Likelihood of Return of Spontaneous Circulation After Out of Hospital Cardiac Arrest
    Moore, Johanna C.
    Holley, Joseph
    Scheppke, Kenneth A.
    Salverda, Bayert
    Rojas-Salvador, Carolina
    Jacobs, Michael
    Nystrom, Paul
    Quinn, Ryan
    Adams, Paul J.
    Debaty, Guillaume P.
    Hutchison, Mack
    Mason, Charles
    Martinez, Eduardo
    Mason, Steven
    Clift, Armando
    Antevy, Peter
    Grizzard, Eric
    Lick, Charles
    Garay, Sebastian
    Duval, Sue
    Lurie, Keith G.
    Pepe, Paul E.
    CIRCULATION, 2020, 142 (24) : E495 - E495
  • [47] Effect of stomach inflation during cardiopulmonary resuscitation on return of spontaneous circulation in out-of-hospital cardiac arrest patients: A retrospective observational study
    Naito, Hiromichi
    Hanafusa, Hiroaki
    Hongo, Takashi
    Yumoto, Tetsuya
    Yorifuji, Takashi
    Weissman, Alexandra
    Rittenberger, Jon C.
    Guyette, Francis X.
    Fujishima, Mamoru
    Maeyama, Hiroki
    Nakao, Astunori
    RESUSCITATION, 2023, 193
  • [48] Haemodynamic impact of aortic balloon occlusion combined with percutaneous left ventricular assist device during cardiopulmonary resuscitation in a swine model of cardiac arrest
    Tiba, Mohamad Hakam
    Nakashima, Takahiro
    McCracken, Brendan M.
    Hsu, Cindy H.
    Gottula, Adam L.
    Greer, Nicholas L.
    Cramer, Traci A.
    Sutton, Nadia R.
    Ward, Kevin R.
    Neumar, Robert W.
    RESUSCITATION, 2023, 189
  • [49] Female Physician Leadership During Cardiopulmonary Resuscitation Is Associated With Improved Patient Outcomes
    Meier, Angela
    Yang, Jenny
    Liu, Jinyuan
    Beitler, Jeremy R.
    Tu, Xin M.
    Owens, Robert L.
    Sundararajan, Radhika L.
    Malhotra, Atul
    Sell, Rebecca E.
    CRITICAL CARE MEDICINE, 2019, 47 (01) : E8 - E13
  • [50] Inhibition of nitric oxide improves coronary perfusion pressure and return of spontaneous circulation in a porcine cardiopulmonary resuscitation model
    Krismer, AC
    Lindner, KH
    Wenzel, V
    Rainer, B
    Mueller, G
    Lingnau, V
    CRITICAL CARE MEDICINE, 2001, 29 (03) : 482 - 486