Technical note: Validating a dynamometer for noninvasive measuring of udder firmness in dairy cows

被引:18
作者
Bertulat, S. [1 ]
Fischer-Tenhagen, C. [1 ]
Werner, A. [1 ]
Heuwieser, W. [1 ]
机构
[1] Free Univ Berlin, Fac Vet Med, Clin Anim Reprod, D-14163 Berlin, Germany
关键词
udder firmness; dynamometer; validation; dairy cow; INTRAMAMMARY PRESSURE; MILKING FREQUENCY; CLINICAL MASTITIS; DRY-OFF; AGREEMENT; LACTATION; ACCURACY; BEHAVIOR; HEALTH; LEVEL;
D O I
10.3168/jds.2012-5370
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Most measurements of udder pressure are based on devices connected to the gland cistern via cannulas. These devices are either inserted in the teat canal or surgically implanted into the udder tissue. In this study, instead of invasively measuring intramammary udder pressure, we measured the udder firmness noninvasively on the udder surface via a dynamometer. These are commonly used in food research to determine crispiness and firmness of fruits. The objective of this study was to validate a hand-held dynamometer for measuring udder firmness in dairy cows. Specifically we set out to determine inter-investigator repeatability considering potential confounders such as investigator, location, and cow. Through modifications in the standard operating procedure for the measurements, inter-investigator repeatability increased from correlation coefficient = 0.80 (n = 275) to correlation coefficient = 0.94 (n = 634). Measurements in different locations within the left hind quarter revealed a firmness gradient from the upper to the lower measuring point. Measurements between the 4 quarters within a cow displayed differences, except between both hind quarters. In 94.8% of the udders, firmness decreased due to milking. The correlation coefficient, however, between firmness changes and milk yield was low (r = 0.42, n = 153). Our data provide evidence that the dynamometer, although imperfect, does provide a reasonable measure of udder firmness and can be a useful tool in research related to animal health and welfare. However, a standardized operating protocol should be followed to minimize confounding by investigator, location, and quarter.
引用
收藏
页码:6550 / 6556
页数:7
相关论文
共 24 条
  • [21] Intraobserver and interobserver agreement, reproducibility, and accuracy of computed tomographic measurements of pituitary gland dimensions in healthy dogs
    van der Vlugt-Meijer, Roselinda H.
    Meij, Bjorn P.
    Voorhout, George
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (10) : 1750 - 1755
  • [22] Diagnostic accuracy of digital photography and image analysis for the measurement of foot conformation in the horse
    White, J. M.
    Mellow, D. J.
    Duz, M.
    Lischer, C. J.
    Voute, L. C.
    [J]. EQUINE VETERINARY JOURNAL, 2008, 40 (07) : 623 - 628
  • [23] Effect of clinical mastitis on the lactation curve:: A mixed model estimation using daily milk weights
    Wilson, DJ
    González, RN
    Hertl, J
    Schulte, HF
    Bennett, GJ
    Schukken, YH
    Gröhn, YT
    [J]. JOURNAL OF DAIRY SCIENCE, 2004, 87 (07) : 2073 - 2084
  • [24] BOVINE INTRAMAMMARY PRESSURE CHANGES DURING MECHANICAL MILKING
    WITZEL, DA
    MCDONALD, JS
    [J]. JOURNAL OF DAIRY SCIENCE, 1964, 47 (12) : 1378 - &