Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access

被引:17
作者
Greif, Martin [1 ,2 ]
Lange, Philipp [2 ]
Mair, Helmut [3 ]
Becker, Christoph [4 ]
Schmitz, Christoph [3 ]
Steinbeck, Gerhard [2 ]
Kupatt, Christian [2 ]
机构
[1] Univ Hosp Munich, Klinikum Grosshadern, Dept Cardiol, D-81377 Munich, Germany
[2] Univ Hosp Munich, Klinikum Grosshadern, Med Klin & Poliklin 1, D-81377 Munich, Germany
[3] Univ Hosp Munich, Klinikum Grosshadern, Herzchirurg Klin, D-81377 Munich, Germany
[4] Univ Hosp Munich, Klinikum Grosshadern, Inst Klin Radiol, D-81377 Munich, Germany
关键词
TAVI; Valve in valve; Transfemoral access; Degenerated bioprostheses; HIGH-RISK PATIENTS; HEART-VALVES; REVALVING SYSTEM; CLINICAL-TRIALS; REPLACEMENT; COREVALVE; STENOSIS; SURGERY; SERIES;
D O I
10.1007/s00392-012-0488-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Surgical treatment of degenerated aortic bioprostheses is associated with an increased risk of morbidity and mortality, especially in elderly patients with significant co-morbidities. Therefore, transcatheter aortic valve implantation (TAVI) performed as valve in valve technique appears as an attractive alternative treatment option. We report of a case series of seven patients with dysfunctional bioprosthetic aortic heart valves who have been treated with TAVI via transfemoral access. Valve in valve implantation using the Edwards Sapien XT bioprostheses (Edwards Lifesciences LLC, Irvine, CA, USA) was performed in eight patients (3 men, 5 women, mean age 85.3 +/- A 6.1 years) with a high operative risk (logistic euroSCORE 27.2 +/- A 7.3). Six patients underwent TAVI because of high grade stenosis of the aortic bioprostheses, whereas two patients presented with high grade regurgitation. All patients suffered at least from NYHA class III dyspnea during admission. TAVI was successfully performed via transfemoral access under local anesthesia with mild analgesic medication in all cases. Mild aortic regurgitation occurred in three patients while no permanent pacemaker implantation was required. Major cardiac events or cerebrovascular events did not occur. One aneurysm spurium, with the need of one blood transfusion, occurred. All patients improved at least one NYHA class within 30 days. TAVI for degenerated aortic bioprostheses, using the Edwards Sapien XT valve via transfemoral access is a feasible option for patients at high surgical risk.
引用
收藏
页码:993 / 1001
页数:9
相关论文
共 23 条
[1]   Transcatheter Heart Valves for Failing Bioprostheses State-of-the-Art Review of Valve-in-Valve Implantation [J].
Azadani, Ali N. ;
Tseng, Elaine E. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) :621-U189
[2]   Transcatheter aortic valves inadequately relieve stenosis in small degenerated bioprostheses [J].
Azadani, Ali N. ;
Jaussaud, Nicolas ;
Matthews, Peter B. ;
Ge, Liang ;
Chuter, Timothy A. M. ;
Tseng, Elaine E. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 11 (01) :70-77
[3]   Transcatheter Valve-in-Valve Implantation Using Core Valve Revalving System for Failed Surgical Aortic Bioprostheses [J].
Bedogni, Francesco ;
Laudisa, Maria Luisa ;
Pizzocri, Samuele ;
Tamburino, Corrado ;
Ussia, Gian Paolo ;
Petronio, Anna Sonia ;
Napodano, Massimo ;
Ramondo, Angelo ;
Presbitero, Patrizia ;
Ettori, Federica ;
Santoro, Gennaro ;
Klugman, Silvio ;
De Marco, Federico ;
Brambilla, Nedy ;
Testa, Luca .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) :1228-1234
[4]   Valve-in-Valve Transcatheter Aortic Valve Implantation for Degenerated Bioprosthetic Heart Valves [J].
Eggebrecht, Holger ;
Schaefer, Ulrich ;
Treede, Hendrik ;
Boekstegers, Peter ;
Babin-Ebell, Joerg ;
Ferrari, Markus ;
Moellmann, Helge ;
Baumgartner, Helmut ;
Carrel, Thierry ;
Kahlert, Philipp ;
Lange, Philipp ;
Walther, Thomas ;
Erbel, Raimund ;
Mehta, Rajendra H. ;
Thielmann, Matthias .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (11) :1218-1227
[5]   Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature [J].
Figulla, L. ;
Neumann, A. ;
Figulla, H. R. ;
Kahlert, P. ;
Erbel, R. ;
Neumann, T. .
CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (04) :265-276
[6]   Transcatheter Aortic Valve Implantation for Treatment of Patients With Degenerated Aortic Bioprostheses - Valve-in-Valve Technique [J].
Gotzmann, Michael ;
Muegge, Andreas ;
Bojara, Waldemar .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (07) :1000-1006
[7]   Coronary Obstruction Following Transcatheter Aortic Valve-in-Valve Implantation For Failed Surgical Bioprostheses [J].
Gurvitch, Ronen ;
Cheung, Anson ;
Bedogni, Francesco ;
Webb, John G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (03) :439-444
[8]   Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: Final report of the Veterans Affairs randomized trial [J].
Hammermeister, K ;
Sethi, GK ;
Henderson, WG ;
Grover, FL ;
Oprian, C ;
Rahimtoola, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1152-1158
[9]   Repeat heart valve surgery: Risk factors for operative mortality [J].
Jones, JM ;
O'Kane, H ;
Gladstone, DJ ;
Sarsam, MAI ;
Campalani, G ;
MacGowan, SW ;
Cleland, J ;
Cran, GW .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (05) :913-918
[10]   Comparison of bioprosthesis and mechanical valves, a meta-analysis of randomised clinical trials [J].
Kassaï, B ;
Gueyffier, F ;
Cucherat, M ;
Boissel, JP .
CARDIOVASCULAR SURGERY, 2000, 8 (06) :477-483