Early Single-Site Experience With Transcatheter Tricuspid Valve Replacement

被引:65
作者
Hahn, Rebecca T. [1 ]
George, Isaac [1 ]
Kodali, Susheel K. [1 ]
Nazif, Tamim [1 ]
Khalique, Omar K. [1 ]
Akkoc, Deniz [1 ]
Kantor, Alex [1 ]
Vahl, Torsten P. [1 ]
Patel, Amisha [1 ]
Elias, Elliott [1 ]
Ng, Vivian [1 ]
Spina, Roberto [1 ]
Bartus, Krzysztof [2 ]
Velagapudi, Poonam [2 ]
Wu, Isaac [1 ]
Leon, Martin [1 ]
Bapat, Vinayak [1 ]
机构
[1] Columbia Univ, NewYork Presbyterian Hosp, Med Ctr, 177 Ft Washington Ave, New York, NY 10032 USA
[2] Jagiellonian Univ, John Paul Hosp 2, Med Coll, Dept Cardiovasc Surg & Transplantol, Krakow, Poland
关键词
tricuspid regurgitation; tricuspid valve; valve replacement; AMERICAN SOCIETY; REGURGITATION; ECHOCARDIOGRAPHY; RECOMMENDATIONS; QUANTIFICATION; REPAIR; SYSTEM; DP/DT;
D O I
10.1016/j.jcmg.2018.08.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study presents a single-site experience of 5 patients with severe tricuspid regurgitation (TR) who underwent implantation of a novel transcatheter tricuspid valve replacement device. BACKGROUND Functional TR is the most common etiology of severe TR in the developed world and is associated with unfavorable clinical outcomes. Although numerous transcatheter repair devices are currently in early clinical trials, most result in incomplete degrees of TR reduction and functional improvement. METHODS Transcatheter tricuspid valve replacement was performed in 5 patients with compassionate use of the novel GATE System. All patients had symptomatic, massive and/or torrential TR at baseline. All patients had computed tomography, transthoracic and transesophageal echocardiographic assessment of the tricuspid valve and right heart anatomy. All patients had a surgical transatrial approach performed with valve implantation guided by fluoroscopy and intraprocedural transesophageal echocardiography. RESULTS Baseline characteristics of the patients showed a substantial burden of comorbidities. All patients had successful implantation of the transcatheter valve, with significant reduction of TR to <= 2+. Baseline poor right ventricular (RV) function measured by global longitudinal strain and RV change in pressure divided by change in time were associated with post-implantation RV failure and poor clinical outcomes in this small group. Four of the 5 patients were followed for 3 to 6 months following the initial implantation and showed evidence of RV remodeling, increased cardiac output, and reduction in New York Heart Association functional class. CONCLUSIONS Implantation of a first-generation TTVR device was technically feasible in patients with more than severe TR. Transcatheter tricuspid valve replacement was associated with RV remodeling, increased cardiac output, and improvement in New York Heart Association functional class in most patients. Further studies are needed to refine patient population selection for this device and to determine long-term outcomes. (C) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:416 / 429
页数:14
相关论文
共 29 条
[1]   Clinical value of echocardiographic Doppler-derived right ventricular dp/dt in patients with pulmonary arterial hypertension [J].
Ameloot, Koen ;
Palmers, Pieter-Jan ;
Vande Bruaene, Alexander ;
Gerits, Annelies ;
Budts, Werner ;
Voigt, Jens-Uwe ;
Delcroix, Marion .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (12) :1411-1419
[2]  
[Anonymous], 2017, J AM HEART ASS
[3]  
[Anonymous], 2016, CIRC CARDIOVASC IMAG
[4]   Right atrial size and tricuspid regurgitation severity predict mortality or transplantation in primary pulmonary hypertension [J].
Bustamante-Labarta, M ;
Perrone, S ;
de la Fuente, RL ;
Stutzbach, P ;
de la Hoz, RP ;
Torino, A ;
Favaloro, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (10) :1160-1164
[5]   First-in-Man Experience of a Novel Transcatheter Repair System for Treating Severe Tricuspid Regurgitation [J].
Campelo-Parada, Francisco ;
Perlman, Gidon ;
Philippon, Francois ;
Ye, Jian ;
Thompson, Christopher ;
Bedard, Elisabeth ;
Altisent, Omar Abdul-Jawad ;
Del Trigo, Maria ;
Leipsic, Jonathon ;
Blanke, Philipp ;
Dvir, Danny ;
Puri, Rishi ;
Webb, John G. ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (22) :2475-2483
[6]   Transcatheter interventions for tricuspid regurgitation - heterotopic technology: TricValve [J].
Figulla, Hans R. ;
Kiss, Katharina ;
Lauten, Alexander .
EUROINTERVENTION, 2016, 12 :Y116-Y118
[7]   The need for a new tricuspid regurgitation grading scheme [J].
Hahn, Rebecca T. ;
Zamorano, Jose L. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (12) :1342-1343
[8]   Early Feasibility Study of a Transcatheter Tricuspid Valve Annuloplasty SCOUT Trial 30-Day Results [J].
Hahn, Rebecca T. ;
Meduri, Christopher U. ;
Davidson, Charles J. ;
Lim, Scott ;
Nazif, Tamim M. ;
Ricciardi, Mark J. ;
Rajagopal, Vivek ;
Ailawadi, Gorav ;
Vannan, Mani A. ;
Thomas, James D. ;
Fowler, Dale ;
Rich, Stuart ;
Martin, Randy ;
Ong, Geraldine ;
Groothuis, Adam ;
Kodali, Susheel .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (14) :1795-1806
[9]   Guidelines for Performing a Comprehensive Transesophageal Echocardiographic Examination: Recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists [J].
Hahn, Rebecca T. ;
Abraham, Theodore ;
Adams, Mark S. ;
Bruce, Charles J. ;
Glas, Kathryn E. ;
Lang, Roberto M. ;
Reeves, Scott T. ;
Shanewise, Jack S. ;
Siu, Samuel C. ;
Stewart, William ;
Picard, Michael H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (09) :921-964
[10]   Development of tricuspid regurgitation late after left-sided valve surgery: A single-center experience with long-term echocardiographic examinations [J].
Kwak, Jae-Jin ;
Kim, Yong-Jin ;
Kim, Min-Kyung ;
Kim, Hyung-Kwan ;
Park, Jin-Shik ;
Kim, Kyung-Hwan ;
Kim, Ki-Bong ;
Ahn, Hyuk ;
Sohn, Dae-Won ;
Oh, Byung-Hee ;
Park, Young-Bae .
AMERICAN HEART JOURNAL, 2008, 155 (04) :732-737