Pollutant Exposures from Natural Gas Cooking Burners: A Simulation-Based Assessment for Southern California

被引:78
作者
Logue, Jennifer M. [1 ,2 ]
Klepeis, Neil E. [3 ,4 ]
Lobscheid, Agnes B. [1 ]
Singer, Brett C. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Environm Energy Technol Div, Indoor Environm Grp, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Environm Energy Technol Div, Residential Bldg Syst Grp, Berkeley, CA 94720 USA
[3] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA 94305 USA
[4] San Diego State Univ, Res Fdn, Ctr Behav Epidemiol & Community Hlth C BEACH, Grad Sch Publ Hlth, San Diego, CA 92182 USA
关键词
INDOOR AIR-QUALITY; NITROGEN-DIOXIDE; RESPIRATORY SYMPTOMS; NO2; CONCENTRATIONS; ENVIRONMENTS; ASSOCIATION; PERFORMANCE; VENTILATION; HOMES;
D O I
10.1289/ehp.1306673
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
BACKGROUND: Residential natural gas cooking burners (NGCBs) can emit substantial quantities of pollutants, and they are typically used without venting range hoods. OBJECTIVE: We quantified pollutant concentrations and occupant exposures resulting from NGCB use in California homes. METHODS: A mass-balance model was applied to estimate time-dependent pollutant concentrations throughout homes in Southern California and the exposure concentrations experienced by individual occupants. We estimated nitrogen dioxide (NO2), carbon monoxide (CO), and formaldehyde (HCHO) concentrations for 1 week each in summer and winter for a representative sample of Southern California homes. The model simulated pollutant emissions from NGCBs as well as NO2 and CO entry from outdoors, dilution throughout the home, and removal by ventilation and deposition. Residence characteristics and outdoor concentrations of NO2 and CO were obtained from available databases. We inferred ventilation rates, occupancy patterns, and burner use from household characteristics. We also explored proximity to the burner(s) and the benefits of using venting range hoods. Replicate model executions using independently generated sets of stochastic variable values yielded estimated pollutant concentration distributions with geometric means varying by < 10%. RESULTS: The simulation model estimated that-in homes using NGCBs without coincident use of venting range hoods-62%, 9%, and 53% of occupants are routinely exposed to NO2, CO, and HCHO levels that exceed acute health-based standards and guidelines. NGCB use increased the sample median of the highest simulated 1-hr indoor concentrations by 100, 3,000, and 20 ppb for NO2, CO, and HCHO, respectively. CONCLUSIONS: Reducing pollutant exposures from NGCBs should be a public health priority. Simulation results suggest that regular use of even moderately effective venting range hoods would dramatically reduce the percentage of homes in which concentrations exceed health-based standards.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 46 条
[1]   MEASURING HUMAN EXPOSURE TO CARBON-MONOXIDE IN WASHINGTON, DC, AND DENVER, COLORADO, DURING THE WINTER OF 1982-1983 [J].
AKLAND, GG ;
HARTWELL, TD ;
JOHNSON, TR ;
WHITMORE, RW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1985, 19 (10) :911-918
[2]  
[Anonymous], 2011, R: A Language and Environment for Statistical Computing
[3]   LOWER RESPIRATORY SYMPTOMS IN CHILDREN EXPOSED TO NITROGEN-DIOXIDE FROM UNVENTED COMBUSTION SOURCES [J].
BERWICK, M ;
LEADERER, BP ;
STOLWIJK, JA ;
ZAGRANISKI, RT .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :369-373
[4]  
California Energy Commission (CEC), 2004, 40004009 CEC
[5]  
CARB (California Air Resources Board), 2010, CA AMB AIR QUAL STAN
[6]   Performance Assessment of U.S. Residential Cooking Exhaust Hoods [J].
Delp, William W. ;
Singer, Brett C. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (11) :6167-6173
[7]  
Fortmann R., 2001, INDOOR AIR QUALITY R
[8]   Nitrogen dioxide in Australian homes: Levels and sources [J].
Garrett, MH ;
Hooper, MA ;
Hooper, BM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (01) :76-81
[9]   Association of air pollution with daily GP consultations for asthma and other lower respiratory conditions in London [J].
Hajat, S ;
Haines, A ;
Goubet, SA ;
Atkinson, RW ;
Anderson, HR .
THORAX, 1999, 54 (07) :597-605
[10]  
Health Effects Institute, 2010, REL IND OUTD PERS AI