Rough Sets for Bias Field Correction in MR Images Using Contraharmonic Mean and Quantitative Index

被引:17
作者
Banerjee, Abhirup [1 ]
Maji, Pradipta [1 ]
机构
[1] Indian Stat Inst, Machine Intelligence Unit, Kolkata 700108, India
关键词
Bias field; contraharmonic mean filter; intensity inhomogeneity; magnetic resonance imaging (MRI); rough sets; INHOMOGENEITY CORRECTION; INTENSITY NONUNIFORMITY; SEGMENTATION; ALGORITHM; N3;
D O I
10.1109/TMI.2013.2274804
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
One of the challenging tasks for magnetic resonance (MR) image analysis is to remove the intensity inhomogeneity artifact present in MR images, which often degrades the performance of an automatic image analysis technique. In this regard, the paper presents a novel approach for bias field correction in MR images. It judiciously integrates the merits of rough sets and contraharmonic mean. While the contraharmonic mean is used in low-pass averaging filter to estimate the bias field in multiplicative model, the concept of lower approximation and boundary region of rough sets deals with vagueness and incompleteness in filter structure definition. A theoretical analysis is presented to justify the use of both rough sets and contraharmonic mean for bias field estimation. The integration enables the algorithm to estimate optimum or near optimum bias field. Some new quantitative indexes are introduced to measure intensity inhomogeneity artifact present in a MR image. The performance of the proposed approach, along with a comparison with other approaches, is demonstrated on both simulated and real MR images for different bias fields and noise levels.
引用
收藏
页码:2140 / 2151
页数:12
相关论文
共 25 条
[1]   A modified fuzzy C-means algorithm for bias field estimation and segmentation of MRI data [J].
Ahmed, MN ;
Yamany, SM ;
Mohamed, N ;
Farag, AA ;
Moriarty, T .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (03) :193-199
[2]  
Ardizzone E., 2005, P 13 INT C IM AN PRO, P922
[3]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[4]   TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[5]   A dual approach for minimizing false lesion classifications on magnetic resonance images [J].
Bedell, BJ ;
Narayana, PA ;
Wolinsky, JS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :94-102
[6]   CORRECTION FOR INTENSITY FALLOFF IN SURFACE COIL MAGNETIC-RESONANCE IMAGING [J].
BREY, WW ;
NARAYANA, PA .
MEDICAL PHYSICS, 1988, 15 (02) :241-245
[7]   Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correction [J].
Brinkmann, BH ;
Manduca, A ;
Robb, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (02) :161-171
[8]   Template-Based B1 Inhomogeneity Correction in 3T MRI Brain Studies [J].
Castro, Marcelo A. ;
Yao, Jianhua ;
Pang, Yuxi ;
Lee, Christabel ;
Baker, Eva ;
Butman, John ;
Evangelou, Iordanis E. ;
Thomasson, David .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) :1927-1941
[9]   CORRECTION OF INTENSITY VARIATIONS IN MR-IMAGES FOR COMPUTER-AIDED TISSUE CLASSIFICATION [J].
DAWANT, BM ;
ZIJDENBOS, AP ;
MARGOLIN, RA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) :770-781
[10]   Method for bias field correction of brain T1-weighted magnetic resonance images minimizing segmentation error [J].
Gispert, JD ;
Reig, S ;
Pascau, J ;
Vaquero, JJ ;
García-Barreno, P ;
Desco, M .
HUMAN BRAIN MAPPING, 2004, 22 (02) :133-144