Nanostructured voltammetric sensor for ultra-trace anabolic drug determination in food safety field

被引:14
作者
Regiart, Matias [1 ]
Pereira, Sirley V. [1 ]
Spotorno, Viviana G. [2 ]
Bertolino, Franco A. [1 ]
Raba, Julio [1 ]
机构
[1] Univ Nacl San Luis, CONICET, Dept Quim, INQUISAL, San Luis, Argentina
[2] INTA, Inst Nacl Tecnol Agr, CIRN, IRB,Inst Recursos Biol, Buenos Aires, DF, Argentina
关键词
Voltammetric sensor; Nanostructured platform; Anabolic drug; Food safety; BETA-ADRENERGIC AGONISTS; LIQUID-CHROMATOGRAPHY; CARBON NANOTUBES; MICROFLUIDIC IMMUNOSENSOR; RAPID-DETERMINATION; BOVINE HAIR; HUMAN URINE; ILLEGAL USE; CLENBUTEROL; BIOSENSOR;
D O I
10.1016/j.snb.2013.07.117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive electrochemical sensor for clenbuterol (CL) determination in bovine urine samples was designed. This drug was originally developed for the treatment of respiratory pathologies. However, in the livestock industry, CL has been used as growth promoter because it stimulates the muscle growth and lipid degradation. The drug residues accumulated in animal tissues represent a potential risk for the human health. Subsequently, the development of a fast and simple method for the CL quantification employed to detect its abuse in livestock production is an attractive analytical challenge. The proposed method was based on the use of a screen printed carbon electrode (SPCE) modified with multiwall carbon nanotubes (MWCNTs) in a matrix of chitosan (CH) on gold nanoparticles (AuNPs) previously incorporated by electrodeposition process. The MWCNTs-CH/AuNPs/SPCE was characterized by cyclic voltammetry, X-ray diffraction and scan electron microscopy. With the aim to carry out the CL determination, a pre-concentration procedure was required. For this purpose, we employed anti-CL antibodies immobilized on magnetic microparticles (MPs) as bioaffinity support to capture the drug present in the sample. This support was exposed to a desorption process. Later, the electrochemical detection by square wave voltammetry (OSWV) was performed. The sensor exhibited excellent performances with a linear response range in concentrations from 0.01 to 6 ng mL(-1). The detection and quantification limits obtained were 0.003 and 0.01 ng mL(-1), respectively with an analysis time of 19 min and a R. S. D. below 5.8%. As a conclusion, we can claim that the results obtained by the proposed sensor were successful. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:1241 / 1249
页数:9
相关论文
共 50 条
  • [41] Determination of ultra-trace level Cr(VI) in seawater using large-volume direct injection by LC-ICP-MS with in-line matrix elimination
    Yao, Zhenzhen
    Li, Bingru
    Ma, Zhihong
    Wang, Beihong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (03) : 954 - 961
  • [42] Construction of an ultra-sensitive electrochemical sensor based on polyoxometalates decorated with CNTs and AuCo nanoparticles for the voltammetric simultaneous determination of dopamine and uric acid
    Bai, Zhenyuan
    Gao, Ning
    Xu, Hengbin
    Wang, Xinming
    Tan, Lichao
    Pang, Haijun
    Ma, Huiyuan
    MICROCHIMICA ACTA, 2020, 187 (08)
  • [43] Extended Gate Field Effect Transistor Based Sensor for Detection of Trace Amounts of Anti-Depressant Drug
    Sheibani, Shokoofeh
    Ionescu, Adrian M.
    Norouzi, Parviz
    IEEE ACCESS, 2020, 8 (08): : 198010 - 198020
  • [44] Coral-like, self-assembled, and spatially bounded Ag nano-particles on franzinite zeolite composite sensor toward accurate, synergetic, and ultra-trace sulfadiazine detection
    Zhu, Xinyu
    Li, Zhuozhe
    Fang, Fang
    Yifeng, E.
    Chen, Peng
    Li, Li
    Qian, Kun
    ANALYTICA CHIMICA ACTA, 2023, 1276
  • [45] Highly selective preconcentration of ultra-trace amounts of lead ions in real water and food samples by dispersive solid phase extraction using modified magnetic graphene oxide as a novel sorbent
    Akbarzade, S.
    Chamsaz, M.
    Rounaghi, G. H.
    ANALYTICAL METHODS, 2018, 10 (18) : 2081 - 2087
  • [46] Magnetic Solid-Phase Extraction Based on Modified Iron Oxide Nanoparticles for the Preconcentration of Ultra-Trace Amounts of Copper Ions in the Environmental and Plant Samples and its Determination Using FAAS
    Mohammadi, Sayed Zia
    Rohani, Tahereh
    Bahadori, Leila
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2017, 48 (11) : 1359 - 1368
  • [47] Helical multi-walled carbon nanotube-coated fibers for solid-phase microextraction determination of polycyclic aromatic hydrocarbons at ultra-trace levels in ice and snow samples
    Arcoleo, Angela
    Bianchi, Federica
    Careri, Maria
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1631
  • [48] Simultaneous determination and extraction of ultra-trace amounts of estradiol valerate from whole blood using FFT square wave voltammetry and low-voltage electrically enhanced microextraction techniques
    Mofidi, Zahra
    Norouzi, Parviz
    Larijani, Bagher
    Seidi, Shahram
    Ganjali, Mohammad Reza
    Morshedi, Mahboobe
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 813 : 83 - 91
  • [49] Experimental and theoretical studies of a novel electrochemical sensor based on molecularly imprinted polymer and B, N, F-CQDs/AgNPs for enhanced specific identification and dual signal amplification in highly selective and ultra-trace bisphenol S determination in plastic products
    Yao, Jun
    Chen, Min
    Li, Nannan
    Liu, Chaohui
    Yang, Mei
    ANALYTICA CHIMICA ACTA, 2019, 1066 : 36 - 48
  • [50] Determination of ultra-trace level 241Am in soil by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with chemical separation
    Zhang, Weichao
    Lin, Jianfeng
    Zhang, Haitao
    Fang, Sui
    Li, Chen
    Yi, Xiaowei
    Dang, Haijun
    Xu, Yihong
    Wang, Wei
    Xu, Jiang
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (05) : 1044 - 1052