Nanostructured voltammetric sensor for ultra-trace anabolic drug determination in food safety field

被引:14
作者
Regiart, Matias [1 ]
Pereira, Sirley V. [1 ]
Spotorno, Viviana G. [2 ]
Bertolino, Franco A. [1 ]
Raba, Julio [1 ]
机构
[1] Univ Nacl San Luis, CONICET, Dept Quim, INQUISAL, San Luis, Argentina
[2] INTA, Inst Nacl Tecnol Agr, CIRN, IRB,Inst Recursos Biol, Buenos Aires, DF, Argentina
关键词
Voltammetric sensor; Nanostructured platform; Anabolic drug; Food safety; BETA-ADRENERGIC AGONISTS; LIQUID-CHROMATOGRAPHY; CARBON NANOTUBES; MICROFLUIDIC IMMUNOSENSOR; RAPID-DETERMINATION; BOVINE HAIR; HUMAN URINE; ILLEGAL USE; CLENBUTEROL; BIOSENSOR;
D O I
10.1016/j.snb.2013.07.117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive electrochemical sensor for clenbuterol (CL) determination in bovine urine samples was designed. This drug was originally developed for the treatment of respiratory pathologies. However, in the livestock industry, CL has been used as growth promoter because it stimulates the muscle growth and lipid degradation. The drug residues accumulated in animal tissues represent a potential risk for the human health. Subsequently, the development of a fast and simple method for the CL quantification employed to detect its abuse in livestock production is an attractive analytical challenge. The proposed method was based on the use of a screen printed carbon electrode (SPCE) modified with multiwall carbon nanotubes (MWCNTs) in a matrix of chitosan (CH) on gold nanoparticles (AuNPs) previously incorporated by electrodeposition process. The MWCNTs-CH/AuNPs/SPCE was characterized by cyclic voltammetry, X-ray diffraction and scan electron microscopy. With the aim to carry out the CL determination, a pre-concentration procedure was required. For this purpose, we employed anti-CL antibodies immobilized on magnetic microparticles (MPs) as bioaffinity support to capture the drug present in the sample. This support was exposed to a desorption process. Later, the electrochemical detection by square wave voltammetry (OSWV) was performed. The sensor exhibited excellent performances with a linear response range in concentrations from 0.01 to 6 ng mL(-1). The detection and quantification limits obtained were 0.003 and 0.01 ng mL(-1), respectively with an analysis time of 19 min and a R. S. D. below 5.8%. As a conclusion, we can claim that the results obtained by the proposed sensor were successful. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:1241 / 1249
页数:9
相关论文
共 50 条
  • [31] Optimized Preconcentration Method Using Ionic Liquid Ferrofluid for Ultra-Trace Determination of Cr(VI) in Drinking Water by Inductively Coupled Plasma Mass Spectrometry
    Gotame, Yam Nath
    Beauchemin, Diane
    ATOMIC SPECTROSCOPY, 2024, 45 (02) : 115 - 122
  • [32] Ionic Liquid Ferrofluid-Based Preconcentration and Ultra-Trace Determination of As and Se Species in Complex Matrices Using Inductively Coupled Plasma Mass Spectrometry
    Gotame, Yam Nath
    Beauchemin, Diane
    ATOMIC SPECTROSCOPY, 2024, 45 (03)
  • [33] Contribution to food safety assurance of fish consumed at So Paulo city by means of trace element determination
    Fabiano, Karen C.
    Lima, Ana P. S.
    Vasconcellos, Marina B. A.
    Moreira, Edson G.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 309 (01) : 383 - 388
  • [34] A highly sensitive electrochemical sensor for simultaneous voltammetric determination of noradrenaline, acetaminophen, xanthine and caffeine based on a flavonoid nanostructured modified glassy carbon electrode
    Amiri-Aref, Mohaddeseh
    Raoof, Jahan Bakhsh
    Ojani, Reza
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 634 - 641
  • [35] Ultra-trace electrochemical impedance determination of bovine serum albumin by a two dimensional silica network citrate-capped gold nanoparticles modified gold electrode
    Yari, Abdollah
    Saeidikhah, Marzieh
    TALANTA, 2015, 144 : 1336 - 1341
  • [36] Hand-held optical sensor using denatured antibody coated electro-active polymer for ultra-trace detection of copper in blood serum and environmental samples
    Chandra, Sutapa
    Dhawangale, Arvind
    Mukherji, Soumyo
    BIOSENSORS & BIOELECTRONICS, 2018, 110 : 38 - 43
  • [37] Contribution to food safety assurance of fish consumed at São Paulo city by means of trace element determination
    Karen C. Fabiano
    Ana P. S. Lima
    Marina B. A. Vasconcellos
    Edson G. Moreira
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 309 : 383 - 388
  • [38] Sensitive Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
    Selesovska, Renata
    Janikova-Bandzuchova, Lenka
    Chylkova, Jaromira
    ELECTROANALYSIS, 2015, 27 (01) : 42 - 51
  • [39] SrMnO3/Functionalized h-BN Composite Modified Disposable Sensor for the Voltammetric Determination of Furaltadone Antibiotic Drug
    Venkatesh, Krishnan
    Rajakumaran, Ramachandran
    Chen, Shen-Ming
    Karuppasamy, Periyakaruppan
    Banach, Artur
    Al-Onazi, Wedad A.
    Sonadevi, Selvam
    Krishnan, Nattamai Perumal
    Yang, Chun-Chen
    Karuppiah, Chelladurai
    Ramaraj, Sayee Kannan
    CATALYSTS, 2022, 12 (12)
  • [40] Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation
    Huang, Zhaoya
    Ni, Youyi
    Wang, Hai
    Zheng, Jian
    Yamazaki, Shinnosuke
    Sakaguchi, Aya
    Long, Xinggui
    Uchida, Shigeo
    MICROCHEMICAL JOURNAL, 2019, 148 : 597 - 604