Nanostructured voltammetric sensor for ultra-trace anabolic drug determination in food safety field

被引:14
作者
Regiart, Matias [1 ]
Pereira, Sirley V. [1 ]
Spotorno, Viviana G. [2 ]
Bertolino, Franco A. [1 ]
Raba, Julio [1 ]
机构
[1] Univ Nacl San Luis, CONICET, Dept Quim, INQUISAL, San Luis, Argentina
[2] INTA, Inst Nacl Tecnol Agr, CIRN, IRB,Inst Recursos Biol, Buenos Aires, DF, Argentina
关键词
Voltammetric sensor; Nanostructured platform; Anabolic drug; Food safety; BETA-ADRENERGIC AGONISTS; LIQUID-CHROMATOGRAPHY; CARBON NANOTUBES; MICROFLUIDIC IMMUNOSENSOR; RAPID-DETERMINATION; BOVINE HAIR; HUMAN URINE; ILLEGAL USE; CLENBUTEROL; BIOSENSOR;
D O I
10.1016/j.snb.2013.07.117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive electrochemical sensor for clenbuterol (CL) determination in bovine urine samples was designed. This drug was originally developed for the treatment of respiratory pathologies. However, in the livestock industry, CL has been used as growth promoter because it stimulates the muscle growth and lipid degradation. The drug residues accumulated in animal tissues represent a potential risk for the human health. Subsequently, the development of a fast and simple method for the CL quantification employed to detect its abuse in livestock production is an attractive analytical challenge. The proposed method was based on the use of a screen printed carbon electrode (SPCE) modified with multiwall carbon nanotubes (MWCNTs) in a matrix of chitosan (CH) on gold nanoparticles (AuNPs) previously incorporated by electrodeposition process. The MWCNTs-CH/AuNPs/SPCE was characterized by cyclic voltammetry, X-ray diffraction and scan electron microscopy. With the aim to carry out the CL determination, a pre-concentration procedure was required. For this purpose, we employed anti-CL antibodies immobilized on magnetic microparticles (MPs) as bioaffinity support to capture the drug present in the sample. This support was exposed to a desorption process. Later, the electrochemical detection by square wave voltammetry (OSWV) was performed. The sensor exhibited excellent performances with a linear response range in concentrations from 0.01 to 6 ng mL(-1). The detection and quantification limits obtained were 0.003 and 0.01 ng mL(-1), respectively with an analysis time of 19 min and a R. S. D. below 5.8%. As a conclusion, we can claim that the results obtained by the proposed sensor were successful. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:1241 / 1249
页数:9
相关论文
共 50 条
  • [1] Rapid ultra-trace determination of Fukushima-derived radionuclides in food
    Weller, Anica
    Hori, Mayumi
    Shozugawa, Katsumi
    Steinhauser, Georg
    FOOD CONTROL, 2018, 85 : 376 - 384
  • [2] Fabrication of an Extra Sensitive Voltammetric Sensor Using Nanoparticles of Molecularly Imprinted Polymer for Determination of Ultra-Trace Promethazine in Plasma Sample
    Alizadeh, Taher
    Ganjali, Mohammad Reza
    Akhoundian, Maedeh
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10427 - 10441
  • [3] Derivatized silver nanoparticles as sensor for ultra-trace nitrate determination based on light scattering phenomenon
    Wang, Chien C.
    Luconi, Marta O.
    Masi, Adriana N.
    Fernandez, Liliana P.
    TALANTA, 2009, 77 (03) : 1238 - 1243
  • [4] Ultra-trace level voltammetric sensor for MB in human plasma based on a carboxylic derivative of Calix[4]resorcinarene capped silver nanoparticles
    Umar, Abdul Rehman
    Hussain, Kashif
    Aslam, Zara
    Ul Haq, Muhammad Anwar
    Muhammad, Haji
    Sirajuddin
    Shah, Muhammad Raza
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2022, 107 : 81 - 92
  • [5] Voltammetric Sensor Modified by EDTA-immobilized Graphene-like Carbon Nitride Nanosheets: Preparation, Characterization and Selective Determination of Ultra-Trace Pb (II) in Water Samples
    Teng, Zhenyuan
    Lv, Hongying
    Wang, Luona
    Liu, Lin
    Wang, Chengyin
    Wang, Guoxiu
    ELECTROCHIMICA ACTA, 2016, 212 : 722 - 733
  • [6] The boron-doped diamond electrode voltammetric method for ultra-trace determination of the fungicide pyraclostrobin and evaluation of its photodegradation and thermal degradation
    Dornellas, R. M.
    Nogueira, D. B.
    Aucelio, R. Q.
    ANALYTICAL METHODS, 2014, 6 (03) : 944 - 950
  • [7] A molecularly imprinted electrochemiluminescence sensor based on the mimetic enzyme catalytic effect for ultra-trace Ni2+ determination
    Yang, Bin
    Li, Jianping
    Zhang, Lianming
    Xu, Guobao
    ANALYST, 2016, 141 (20) : 5822 - 5828
  • [8] Voltammetric Determination of Acyclovir in Human Urine Using Ultra Trace Graphite and Glassy Carbon Electrodes
    Sadikoglu, Murat
    Saglikoglu, Gulsen
    Yagmur, Sultan
    Orta, Erdem
    Yilmaz, Selehattin
    CURRENT ANALYTICAL CHEMISTRY, 2011, 7 (02) : 130 - 135
  • [9] Controlling contamination for determination of ultra-trace levels of priority pollutants chlorophenols in environmental water matrices
    Kadmi, Yassine
    Favier, Lidia
    Yehya, Tania
    Soutrel, Isabelle
    Simion, Andrei Ionut
    Vial, Christophe
    Wolbert, Dominique
    ARABIAN JOURNAL OF CHEMISTRY, 2019, 12 (08) : 2905 - 2913
  • [10] Ultra-trace determination of mercury in river waters after online UV digestion of humic matter
    Leopold, Kerstin
    Zierhut, Anja
    Huber, Jessica
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (08) : 2419 - 2428