Combined application of dispersive liquid-liquid microextraction based on the solidification of floating organic droplets and charged aerosol detection for the simple and sensitive quantification of macrolide antibiotics in human urine

被引:31
作者
Jia, Shaodong [1 ,2 ,4 ]
Li, Jing [1 ,2 ]
Park, So-Ra [1 ,2 ]
Ryu, Yeonsuk [3 ]
Park, Il Ho [5 ]
Park, Jeong Hill [1 ,2 ]
Hong, Soon-Sun [4 ]
Kwon, Sung Won [1 ,2 ]
Lee, Jeongmi [3 ]
机构
[1] Seoul Natl Univ, Coll Pharm, Seoul 151742, South Korea
[2] Seoul Natl Univ, Pharmaceut Sci Res Inst, Seoul 151742, South Korea
[3] Sungkyunkwan Univ, Sch Pharm, Suwon 440746, South Korea
[4] Inha Univ, Coll Med, Dept Biomed Sci, Inchon 400712, South Korea
[5] Sahmyook Univ, Coll Pharm, Seoul 139742, South Korea
基金
新加坡国家研究基金会;
关键词
Charged aerosol detection; Dispersive liquid-liquid microextraction; Solidification of organic droplets; Macrolide antibiotics; Urine sample; TANDEM MASS-SPECTROMETRY; DETECTION HPLC-ECD; CHROMATOGRAPHIC DETERMINATION; ELECTROCHEMICAL DETECTION; COULOMETRIC DETECTION; DIRECT INJECTION; BIOGENIC-AMINES; SAMPLE CLEANUP; WATER; PLASMA;
D O I
10.1016/j.jpba.2013.07.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel analytical method combining dispersive liquid-liquid microextraction based on the solidification of floating organic droplets (DLLME-SFO) and liquid chromatography with charged aerosol detection (LC-CAD) was established. For the first time, CAD was applied for the detection of macrolide antibiotics lacking chromophores. Parameters influencing the microextraction efficiency were systematically investigated, and the optimized microextraction conditions yielded high enrichment factors in the range of 60-106. The combined application of DLLME-SFO and LC-CAD provided the sensitivity of the method, expressed as the limit of detection (LOD), as low as 10 to 40 ng mL(-1) and intra-day and inter-day precisions below 8.7% and 12.6%, respectively. The measured absolute recovery values were approximately 100%, indicating that the extraction efficiency was very high. Direct comparisons of the liquid-liquid extraction and organic solvent precipitation methods demonstrated that the proposed method was more sensitive, specific, rapid, and environmentally friendly for the determination of five macrolide antibiotics in human urine. The results suggest that the combined use of DLLME-SFO and LC-CAD may be applicable to the analysis of various compounds with poor to no chromophores in complex matrices. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 213
页数:10
相关论文
共 28 条
  • [1] Development and validation of a rapid assay based on liquid chromatography-tandem mass spectromtetry for determining macrolide antibiotic residues in eggs
    Bogialli, Sara
    Ciampanella, Cecilia
    Curini, Roberta
    Di Corcia, Antonio
    Lagana, Aldo
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (40) : 6810 - 6815
  • [2] Separation and Preconcentration by Dispersive Liquid-Liquid Microextraction Procedure: Recent Applications
    Bosch Ojeda, Catalina
    Sanchez Rojas, Fuensanta
    [J]. CHROMATOGRAPHIA, 2011, 74 (9-10) : 651 - 679
  • [3] Determination of Macrolide Antibiotics Using Dispersive Liquid-Liquid Microextraction Followed by Surface-Assisted Laser Desorption/Ionization Mass Spectrometry
    Chen, Kuan-Yu
    Yang, Thomas C.
    Chang, Sarah Y.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (06) : 1157 - 1160
  • [4] One-step in-syringe ionic liquid-based dispersive liquid-liquid microextraction
    Cruz-Vera, Marta
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (37) : 6459 - 6465
  • [5] Determination of macrolide antibiotics in porcine and bovine urine by high-performance liquid chromatography coupled to coulometric detection
    de la Huebra, MJG
    Vincent, U
    Bordin, G
    Rodríguez, A
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (02) : 433 - 439
  • [6] A multiresidue method for the simultaneous determination of ten macrolide antibiotics in human urine based on gradient elution liquid chromatography coupled to coulometric detection (HPLC-ECD)
    de la Huebra, MJG
    Bordin, G
    Rodríguez, AR
    [J]. ANALYTICA CHIMICA ACTA, 2004, 517 (1-2) : 53 - 63
  • [7] Comparative study of coulometric and amperometric detection for the determination of macrolides in human urine using high-performance liquid chromatography
    de la Huebra, MJG
    Bordin, G
    Rodríguez, AR
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (08) : 1031 - 1037
  • [8] de la Huebra MJG, 2003, ELECTROANAL, V15, P473
  • [9] AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF SPIRAMYCIN BY DIRECT INJECTION OF PLASMA, USING COLUMN-SWITCHING FOR SAMPLE CLEANUP
    DOW, J
    LEMAR, M
    FRYDMAN, A
    GAILLOT, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV): : 275 - 283
  • [10] Dispersive liquid-liquid microextraction using extraction solvent lighter than water
    Farajzadeh, Mir Ali
    Seyedi, Seyed Esmaeil
    Shalamzari, Mohammad Safi
    Bamorowat, Mehdi
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) : 3191 - 3200