Comparison of optical and electromagnetic tracking for navigated lateral skull base surgery

被引:45
作者
Kral, Florian [1 ]
Puschban, Elisabeth J. [1 ]
Riechelmann, Herbert [1 ]
Freysinger, Wolfgang [1 ]
机构
[1] Med Univ Innsbruck, Dept Otorhinolaryngol, A-6020 Innsbruck, Austria
关键词
navigation; tracking; skull base surgery; SUBMILLIMETER ACCURACY; REGISTRATION; SYSTEM; STABILITY; BONE;
D O I
10.1002/rcs.1502
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Navigation with optical tracking sometimes makes it difficult to establish a line-of-sight in cluttered operating theatres. On the other hand, the accuracy of electromagnetic tracking is influenced by ferromagnetic surgical equipment. We compared electromagnetic with optical tracking under controlled conditions for the lateral skull base. Methods Six anatomical specimens were dissected to measure the target registration error (TRE) in and around the petrous bone in a wet laboratory to simulate an intraoperative setting. Specimens were registered with passive optical and electromagnetic tracking. Results Overall accuracy was better using optical tracking than electromagnetic tracking (0.22mm; 0.07-0.48 vs 0.99mm; 0.56-1.27mm; median, lower and upper quartiles, respectively; p<0.001). Conclusion The accuracy of optical tracking was near the resolution of the camera system, whereas the accuracy of electromagnetic tracking was lower. Only optical tracking allows for an application accuracy of considerably less than 1mm in high-resolution datasets. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:247 / 252
页数:6
相关论文
共 17 条
[1]   Systematic distortions in magnetic position digitizers [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Enislidis, G ;
Kollmann, C ;
Rafolt, D ;
Nowotny, R .
MEDICAL PHYSICS, 1998, 25 (11) :2242-2248
[2]  
Caversaccio M, 2000, AM J OTOL, V21, P863
[3]   The distribution of target registration error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) :917-927
[4]   Accuracy assessment protocols for electromagnetic tracking systems [J].
Frantz, DD ;
Wiles, AD ;
Leis, SE ;
Kirsch, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14) :2241-2251
[5]   Evaluation of accuracy of an electromagnetic computer-assisted navigation system in total knee arthroplasty [J].
Graydon, A. J. ;
Malak, S. ;
Anderson, I. A. ;
Pitto, R. P. .
INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) :975-979
[6]   Evaluation of a new electromagnetic tracking system using a standardized assessment protocol [J].
Hummel, J ;
Figl, M ;
Birkfellner, W ;
Bax, MR ;
Shahidi, R ;
Maurer, CR ;
Bergmann, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :N205-N210
[7]   Contour and paired-point registration in a model for image-guided surgery [J].
Knott, P. Daniel ;
Batra, Pete S. ;
Butler, Robert S. ;
Citardi, Martin J. .
LARYNGOSCOPE, 2006, 116 (10) :1877-1881
[8]  
Kral F, 2004, HNO, V52, P699, DOI 10.1007/s00106-003-0964-1
[9]   In vitro assessment of image-guided otologic surgery: Submillimeter accuracy within the region of the temporal bone [J].
Labadie, RF ;
Shah, RJ ;
Harris, SS ;
Cetinkaya, E ;
Haynes, DS ;
Fenlon, MR ;
Juszczyk, AS ;
Galloway, RL ;
Fitzpatrick, JM .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2005, 132 (03) :435-442
[10]   A true minimally invasive approach for cochlear implantation: High accuracy in cranial base navigation through flat-panel-based volume computed tomography [J].
Majdani, Omid ;
Bartling, Soenke H. ;
Leinung, Martin ;
Stoever, Timo ;
Lenarz, Minoo ;
Dullin, Christian ;
Lenarz, Thomas .
OTOLOGY & NEUROTOLOGY, 2008, 29 (02) :120-123