摘要
By direct coupling with a hydro-dynamically controlled gearbox, wind turbine generators can work at a determined speed, e.g., the synchronous operating point, regardless of the rotor speed. The doubly-fed induction generators operate usually away from the synchronous point due to unbalanced thermal stress on the rotor windings and inverter half-bridges. However, at this operation mode, there is no active power flowing in its rotor and thus the converter rating is reduced considerably, especially in MW-turbines. This work introduces methods to increase transient and oscillatory stability of the generator at the operating point without any modification of the machine structure. Moreover, the ability to ride-through the temporary low voltage is provided with a novel positive and negative sequence separation. The control methods are presented with selected simulation and experimental results.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 14 条
  • [1] Alepuz S., 2007, 2007 European Conference on Power Electronics and Applications, P1
  • [2] [Anonymous], 2006, Grid code high and extra high voltage
  • [3] [Anonymous], 2021, STAT
  • [4] Basteck A, 2009, WINDRIVE LARGE WIND
  • [5] Bellmunt O. G, 2008, ENERGY CONVERSION IE, V23
  • [6] Bruns M, 2009, IEEE POWER ELECT APP, P1
  • [7] Jung J, 2011, IEEE INT EL MACH DRI, P906
  • [8] KAURA V, 1997, IEEE T IND APPL, V33
  • [9] Leonhard W, 1980, REGELUNG ELEKT ENERG, P57
  • [10] Rabelo B, 2009, ETG K OCT DUSS