Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent

被引:41
作者
Ito, Kazuaki [1 ]
Nomura, Ryosuke [1 ]
Fujii, Takuya [1 ]
Tanaka, Masahito [1 ]
Tsumura, Tomoaki [1 ]
Shibata, Hiroyuki [1 ]
Hirokawa, Takeshi [2 ]
机构
[1] Kinki Univ, Dept Biotechnol & Chem, Higashihiroshima 7392116, Japan
[2] Hiroshima Univ, Grad Sch Engn, Dept Appl Chem, Higashihiroshima 7398527, Japan
关键词
Inorganic anions; Seawater; Monolithic ODS column; Dilauryldimethylammonium bromide; NaCl mobile phase; Ultraviolet detection; VENICE LAGOON-WATER; LIQUID-CHROMATOGRAPHY; TRANSIENT ISOTACHOPHORESIS; BACKGROUND ELECTROLYTE; ARTIFICIAL SEAWATER; INORGANIC ANIONS; SEA-WATER; PHASE; ELECTROPHORESIS; THIOCYANATE;
D O I
10.1007/s00216-012-6405-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was developed for determination of inorganic anions, including nitrite (NO (2) (-) ), nitrate (NO (3) (-) ), bromide (Br-), and iodide (I-), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50 x 4.6 mm i.d. and 100 x 4.6 mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5 mol/L; flow rate, 3 mL/min) containing 5 mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225 nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H2O/methanol, 90:10 v/v). The hydrophilic ions (NO (2) (-) , NO (3) (-) , and Br-) were separated within 3 min and the retention time of I- was 16 min. No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35 aEuro degrees artificial seawater. The detection limits were 0.6 mu g/L for NO (2) (-) , 1.1 mu g/L for NO (3) (-) , 70 mu g/L for Br-, and 1.6 mu g/L for I- with a 200-mu L sample injection. The performance of the coated columns was maintained without addition of DDAB in the eluent. The IC system was successfully applied to real seawater samples with recovery rates of 94-108 % for all ions.
引用
收藏
页码:2513 / 2517
页数:5
相关论文
共 27 条
[1]   ADDITIVE EFFECTS ON SURFACTANT ADSORPTION AND IONIC SOLUTE RETENTION IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
BERTHOD, A ;
GIRARD, I ;
GONNET, C .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1362-1367
[2]   Developments in ion chromatography using monolithic columns [J].
Chambers, Stuart D. ;
Glenn, Karen M. ;
Lucy, Charles A. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (11) :1628-1645
[3]   Separation of inorganic anions on a high capacity porous polymeric monolithic column and application to direct determination of anions in seawater [J].
Evenhuis, Christopher J. ;
Buchberger, Wolfgang ;
Hilder, Emily F. ;
Flook, Kelly J. ;
Pohl, Christopher A. ;
Nesterenko, Pavel N. ;
Haddad, Paul R. .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (14) :2598-2604
[4]   Highly sensitive capillary zone electrophoresis with artificial seawater as the background electrolyte and transient isotachophoresis as the on-line concentration procedure for simultaneous determination of nitrite and nitrate in seawater [J].
Fukushi, K ;
Nakayamaa, Y ;
Tsujimoto, J .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1005 (1-2) :197-205
[5]  
GENNARO MC, 1993, ANN CHIM-ROME, V83, P125
[6]   DETERMINATION OF NITRITE, NITRATE, IODIDE, BROMIDE, CHLORIDE, SULFATE, IN VENICE LAGOON-WATER BY REVERSED-PHASE ION-INTERACTION HPLC - THE EFFECT OF THE GEOGRAPHICAL POSITION [J].
GENNARO, MC ;
ABRIGO, C ;
GIACOSA, D ;
SAINI, G .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1995, 30 (03) :675-687
[7]   Improved sensitivity and characterization of high-speed ion chromatography of inorganic anions [J].
Hatsis, P ;
Lucy, CA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :995-1001
[8]   Rapid and direct determination of iodide in seawater by electrostatic ion chromatography [J].
Hu, WZ ;
Yang, PJ ;
Hasebe, K ;
Haddad, PR ;
Tanaka, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 956 (1-2) :103-107
[9]   Direct determination of bromide, nitrate, and iodide in saline matrixes using electrostatic ion chromatography with an electrolyte as eluent [J].
Hu, WZ ;
Haddad, PR ;
Hasebe, K ;
Tanaka, K ;
Tong, P ;
Khoo, C .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1617-1620
[10]   ANION CHROMATOGRAPHY USING OCTADECYLSILANE REVERSED-PHASE COLUMNS COATED WITH CETYLTRIMETHYLAMMONIUM AND ITS APPLICATION TO NITRITE AND NITRATE IN SEAWATER [J].
ITO, K ;
ARIYOSHI, Y ;
TANABIKI, F ;
SUNAHARA, H .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :273-276