Properties of an ideal PET perfusion tracer: New PET tracer cases and data

被引:64
作者
Maddahi, Jamshid [1 ,2 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Mol & Med Pharmacol Nucl Med, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med Cardiol, Los Angeles, CA 90095 USA
关键词
MYOCARDIAL BLOOD-FLOW; POSITRON-EMISSION-TOMOGRAPHY; MODEL;
D O I
10.1007/s12350-011-9491-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An ideal positron emission tomography (PET) tracer should be highly extractable by the myocardium and able to provide high-resolution images, should enable quantification of absolute myocardial blood flow (MBF), should be compatible with both pharmacologically induced and exercise-induced stress imaging, and should not require an on-site cyclotron. The PET radionuclides nitrogen-13 ammonia and oxygen-15 water require an on-site cyclotron. Rubidium-82 may be available locally due to the generator source, but greater utilization is limited because of its relatively low myocardial extraction fraction, long positron range, and generator cost. Flurpiridaz F 18, a novel PET tracer in development, has a high-extraction fraction, short positron range, and relatively long half-life (as compared to currently available tracers), and may be produced at regional cyclotrons. Results of early clinical trials suggest that both pharmacologically and exercise-induced stress PET imaging protocols can be completed more rapidly and with lower patient radiation exposure than with single-photon emission computerized tomography (SPECT) tracers. As compared to SPECT images in the same patients, flurpiridaz F 18 PET images showed better defect contrast. Flurpiridaz F 18 is a potentially promising tracer for assessment of myocardial perfusion, measurement of absolute MBF, calculation of coronary flow reserves, and assessment of cardiac function at the peak of the stress response.
引用
收藏
页码:S30 / S37
页数:8
相关论文
共 19 条
  • [1] [Anonymous], J NUCL CARDIOL
  • [2] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [3] Case J, 2010, J NUCL MED, V51
  • [4] Case J, 2009, J NUCL MED, V50
  • [5] Garcia E.K., 2009, ATLAS NUCL CARDIOLOG, P1
  • [6] Journey to find the ideal PET flow tracer for clinical use: Are we there yet?
    Glover, David K.
    Gropler, Robert J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (06) : 765 - 768
  • [7] Hsu BL, 2010, J NUCL MED, V51
  • [8] RABBIT MYOCARDIAL RB-82 KINETICS AND A COMPARTMENTAL MODEL FOR BLOOD-FLOW ESTIMATION
    HUANG, SC
    WILLIAMS, BA
    KRIVOKAPICH, J
    ARAUJO, L
    PHELPS, ME
    SCHELBERT, HR
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (04): : H1156 - H1164
  • [9] Initial characterization of an 18F-labeled myocardial perfusion tracer
    Huisman, Marc C.
    Higuchi, Takahiro
    Reder, Sybille
    Nekolla, Stephan G.
    Poethko, Thorsten
    Wester, Hans-Juergen
    Ziegler, Sibylle I.
    Casebier, David S.
    Robinson, Simon P.
    Schwaiger, Markus
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (04) : 630 - 636
  • [10] Lazewatsky J, 2010, J NUCL MED, V51