Hydrogen peroxide (H2O2) as a source of dissolved oxygen in COD-degradation respirometric experiments

被引:12
作者
Tusseau-Vuillemin, MH [1 ]
Lagarde, F [1 ]
Chauvière, C [1 ]
Héduit, A [1 ]
机构
[1] CEMAGREF, Unite Rech Qual & fonctionnement Hydrol Syst Aqua, F-92163 Antony, France
关键词
respirometry; hydrogen peroxide; oxygen uptake rate; cod degradation; mixed liquor;
D O I
10.1016/S0043-1354(01)00262-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two different re-oxygenation techniques (aeration and hydrogen peroxide addition) were compared in respirometric experiments. As similar results were obtained in both cases, it was concluded that the addition of hydrogen peroxide does not modify the oxygen uptake rate of the biomass, under either endogenous or feeding conditions. It was hypothesized that under those experimental conditions (inhibition of nitrification with ATU), hydrogen peroxide alters neither the biomass metabolism nor the biodegradability of the tested substrates. The oxygen uptake rates obtained with the aeration system were often more scattered due to the adhesion of fine bubbles after the switch off of the aeration. Moreover, the transfer rate of oxygen to the solution is faster in the case of hydrogen peroxide addition. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:793 / 798
页数:6
相关论文
共 18 条
[1]  
*ASCE, 1996, STAND GUID PROC OXYG, P49
[2]  
COLE CA, 1974, J WATER POLLUT CON F, V46, P2579
[3]  
DEVISSCHER M, 1998, EUR C NEW ADV BIOL
[4]   Determination of nitrification kinetics by the ANITA-DOstat biosensor [J].
Ficara, E ;
Rocco, A ;
Rozzi, A .
WATER SCIENCE AND TECHNOLOGY, 2000, 41 (12) :121-128
[5]  
GILLOT S, 1997, 70 ANN C EXH WAT ENV
[6]   EVALUATION OF OXYGEN-TRANSFER EFFICIENCY AND ALPHA-FACTOR ON A VARIETY OF DIFFUSED AERATION SYSTEMS [J].
GROVES, KP ;
DAIGGER, GT ;
SIMPKIN, TJ ;
REDMON, DT ;
EWING, L .
WATER ENVIRONMENT RESEARCH, 1992, 64 (05) :691-698
[7]   Active biomass in activated sludge: Comparison of respirometry with catalase activity measured using an on-line monitor [J].
Guwy, AJ ;
Buckland, H ;
Hawkes, FR ;
Hawkes, DL .
WATER RESEARCH, 1998, 32 (12) :3705-3709
[8]  
HENZE M, 1992, WATER SCI TECHNOL, V25, P1
[9]  
KAYSER R, 1979, PROG WATER TECHNOL, V11, P23
[10]  
Orhon D, 1997, J CHEM TECHNOL BIOT, V68, P283, DOI 10.1002/(SICI)1097-4660(199703)68:3<283::AID-JCTB633>3.0.CO