A life-cycle cost analysis for an optimum combination of cool coating and thermal insulation of residential building roofs in Tunisia

被引:65
作者
Saafi, Khawla [1 ]
Daouas, Naouel [1 ]
机构
[1] Univ Monastir, Dept Genie Energet, Unite Metrol & Syst Energet, Ecole Natl Ingn Monastir, Rue Ibn El Jazzar, Monastir 5019, Tunisia
关键词
Cool roof; EnergyPlus; Solar reflectivity; Thermal insulation; Life-cycle cost; Optimization; ENERGY SAVINGS; THICKNESS; WALLS; PERFORMANCE; ALBEDO; MODEL; RADIATION; IMPACT;
D O I
10.1016/j.energy.2018.04.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction between the roof thermal insulation and the cool roof effects is assessed in order to determine an optimum combination of the two measures. Dynamic simulations and estimation of the annual energy requirements are performed using EnergyPlus. Two roof structures, three insulation materials and three reflectivity scenarios are considered while taking into account the ageing of the cool material. An energy-based optimization shows that the summertime benefits induced by the rise of reflectivity outweigh the winter penalties, and that the optimum value of the roof reflectivity is the highest possible value. Moderate roof insulation levels with cool roof surfaces of as high as possible reflectivity values are recommended in the Tunisian climate. A 20-year life-cycle cost analysis proves the cost-effectiveness of aged and restored cool roof scenarios for uninsulated roofs with a net saving up to 44.53 TND/m(2) and a payback period of 3.4 years. In terms of maximum net savings and considering the environmental benefits of cool roofs, we recommend an optimum combination of the restored concrete based roof and a 5.4 cm-rockwool thickness. A sensitivity analysis shows that the uncertainties in the economic parameters and changes in the set-point temperatures have a noticeable effect on the optimal parameters. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:925 / 938
页数:14
相关论文
共 42 条
[1]   A review on phase change material (PCM) for sustainable passive cooling in building envelopes [J].
Akeiber, Hussein ;
Nejat, Payam ;
Abd Majid, Muhd Zaimi ;
Wahid, Mazian A. ;
Jomehzadeh, Fatemeh ;
Famileh, Iman Zeynali ;
Calautit, John Kaiser ;
Hughes, Ben Richard ;
Zaki, Sheikh Ahmad .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 60 :1470-1497
[2]  
Al-Sanea S A., 2011, International Journal of Ambient Energy, V23, DOI DOI 10.1080/01430750.2002.9674880
[3]   Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model [J].
Al-Sanea, SA ;
Zedan, MF ;
Al-Ajlan, SA .
APPLIED ENERGY, 2005, 82 (04) :313-330
[4]   Finite-volume thermal analysis of building roofs under two-dimensional periodic conditions [J].
Al-Sanea, SA .
BUILDING AND ENVIRONMENT, 2003, 38 (08) :1039-1049
[5]  
Allen Zielnik A., 2008, J. Archit. Coat, P63
[6]  
[Anonymous], 2006, GUID PRAT CONC LOG E
[7]  
[Anonymous], 2016, ENERGYPLUS ENG REF V
[8]  
[Anonymous], 2016, ENERGYPLUS INP OUTP
[9]  
[Anonymous], 2013, OPP AFF MED FOC EN T
[10]   Optimizing roof insulation for roofs with high albedo coating and radiant barriers in India [J].
Arumugam, Rathish Sathyabama ;
Garg, Vishal ;
Ram, V. Vinayaka ;
Bhatia, Aviruch .
JOURNAL OF BUILDING ENGINEERING, 2015, 2 :52-58