A compact 64-pixel CsI(Tl)/Si PIN photodiode imaging module with IC readout

被引:10
作者
Gruber, GJ [1 ]
Choong, WS [1 ]
Moses, WW [1 ]
Derenzo, SE [1 ]
Holland, SE [1 ]
Pedrali-Noy, M [1 ]
Krieger, B [1 ]
Mandelli, E [1 ]
Meddeler, G [1 ]
Wang, NW [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
gamma camera; photodiode; scientimammography;
D O I
10.1109/TNS.2002.998742
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We characterize the performance of a complete 64-pixel compact gamma camera imaging module consisting of optically isolated 3 X 3 x 5 mm(3) CsI(Tl) crystals coupled to a custom array of low-noise Si PIN photodiodes read out by a custom IC. At 50-V bias, the custom 64-pixel photodiode arrays demonstrate an average leakage current of 28 pA per 3 x 3 mm(2) pixel, a 98.5% yield of pixels with <100 pA leakage, and a quantum efficiency of about 80% for 540-nm CsI(Tl) scintillation photons. The custom 64-channel readout IC uses low-noise preamplifiers, shaper amplifiers, and a winner-take-all (WTA) multiplexer. The IC demonstrates maximum gain of 120 mV/1000 e(-), the ability to select the largest input signal in less than 150 ns, and low electronic noise at 8-mus peaking time ranging from 25 e(-) rms (unloaded) to an estimated 180 e(-) rms (photodiode load of 3 pF, 50 pA). At room temperature, a complete 64-pixel detector module employing a custom photodiode array and readout IC demonstrates an average energy resolution of 23.4% FWHM and an intrinsic spatial resolution of 3.3-mm FWHM for the 140-keV emissions of Tc-99m. Construction of an array of such imaging modules is straightforward; hence this technology shows strong potential for numerous compact gamma camera applications, including scintimammography.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 13 条
[1]  
BUTLER JF, 1998, IEEE T NUCL SCI, V45, P1158
[2]   A discrete scintillation camera module using silicon photodiode readout of CsI(Tl) crystals for breast cancer imaging [J].
Gruber, GJ ;
Moses, WW ;
Derenzo, SE ;
Wang, NW ;
Beuville, E ;
Ho, MH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1063-1068
[3]   Monte Carlo simulation of breast tumor imaging properties with compact, discrete gamma cameras [J].
Gruber, GJ ;
Moses, WW ;
Derenzo, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) :2119-2123
[4]   MEDICAL PROGRESS .1. BREAST-CANCER [J].
HARRIS, JR ;
LIPPMAN, ME ;
VERONESI, U ;
WILLETT, W .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (05) :319-328
[5]   Development of low noise, back-side illuminated silicon photodiode arrays [J].
Holland, SE ;
Wang, NW ;
Moses, WW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :443-447
[6]   A 16-CHANNEL CHARGE SENSITIVE AMPLIFIER IC FOR A PIN PHOTODIODE-ARRAY BASED PET DETECTOR MODULE [J].
MOSES, WW ;
KIPNIS, I ;
HO, MH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1469-1472
[7]   A ''Winner-Take-All'' IC for determining the crystal of interaction in PET detectors [J].
Moses, WW ;
Beuville, E ;
Ho, MH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1615-1618
[8]  
PARKER SL, 1997, CANC J CLIN, V47, P319
[9]   High resolution CsI(Tl)/Si-PIN detector development for breast imaging [J].
Patt, BE ;
Iwanczyk, JS ;
Tull, CR ;
Wang, NW ;
Tornai, MP ;
Hoffman, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2126-2131
[10]   PETRIC - A positron emission tomography readout integrated circuit [J].
Pedrali-Noy, M ;
Grubre, G ;
Krieger, B ;
Mandelli, E ;
Meddeler, G ;
Moses, W ;
Rosso, V .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :479-484