Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI

被引:50
|
作者
Wilm, Bertram J. [1 ,2 ]
Barmet, Christoph [1 ,2 ,3 ]
Gross, Simon [1 ,2 ]
Kasper, Lars [1 ,2 ,4 ]
Vannesjo, S. Johanna [1 ,2 ]
Haeberlin, Max [1 ,2 ]
Dietrich, Benjamin E. [1 ,2 ]
Brunner, David O. [1 ,2 ]
Schmid, Thomas [1 ,2 ]
Pruessmann, Klaas P. [1 ,2 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Skope Magnetic Resonance Technol Inc, Zurich, Switzerland
[4] Univ Zurich, Inst Biomed Engn, Translat Neuromodeling Unit, Zurich, Switzerland
关键词
single-shot spiral; algebraic image reconstruction; magnetic field monitoring; magnetic field probes; DWI; DTI; OFF-RESONANCE CORRECTION; K-SPACE TRAJECTORIES; MAGNETIC-FIELD FLUCTUATIONS; QUANTITATIVE CHARACTERIZATION; RECONSTRUCTION; ECHO; SEPARATION; TENSOR; ACQUISITION; ARTIFACTS;
D O I
10.1002/mrm.26493
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. MethodsImage formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B-0, and coil sensitivity encoding. The encoding model is determined by B-0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. ResultsUsing the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. ConclusionUse of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:83 / 91
页数:9
相关论文
共 50 条
  • [1] Single-shot spiral imaging at 7T
    Engel, Maria
    Kasper, Lars
    Barmet, Christoph
    Schmid, Thomas
    Vionnet, Laetitia
    Wilm, Bertram
    Pruessmann, Klaas P.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1836 - 1846
  • [2] Single-shot spiral diffusion-weighted imaging at 7T using expanded encoding with compressed sensing
    Varela-Mattatall, Gabriel
    Dubovan, Paul I. I.
    Santini, Tales
    Gilbert, Kyle M. M.
    Menon, Ravi S. S.
    Baron, Corey A. A.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (02) : 615 - 623
  • [3] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132
  • [4] Unsupervised deep learning model for correcting Nyquist ghosts of single-shot spatiotemporal encoding
    Bao, Qingjia
    Liu, Xinjie
    Xu, Jingyun
    Xia, Liyang
    Otikovs, Martins
    Xie, Han
    Liu, Kewen
    Zhang, Zhi
    Zhou, Xin
    Liu, Chaoyang
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (04) : 1368 - 1383
  • [5] Acoustic radiation force imaging using a single-shot spiral readout
    Ilovitsh, Asaf
    Fite, Brett Z.
    Ilovitsh, Tali
    Ferrara, Katherine W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12)
  • [6] Effect of Phase Encoding Direction on Image Quality in Single-Shot EPI Diffusion-Weighted Imaging of the Breast
    Rodriguez-Soto, Ana E.
    Zou, Jingjing
    Loubrie, Stephane
    Ebrahimi, Sheida
    Jordan, Stephan
    Schlein, Alexandra
    Lim, Vivian
    Ojeda-Fournier, Haydee
    Rakow-Penner, Rebecca
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1340 - 1349
  • [7] In vivo single-shot 13C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding
    Schmidt, Rita
    Laustsen, Christoffer
    Dumez, Jean-Nicolas
    Kettunen, Mikko I.
    Serrao, Eva M.
    Marco-Rius, Irene
    Brindle, Kevin M.
    Ardenkjaer-Larsen, Jan Henrik
    Frydman, Lucio
    JOURNAL OF MAGNETIC RESONANCE, 2014, 240 : 8 - 15
  • [8] ADC mapping by means of a single-shot spiral MRI technique with application in acute cerebral ischemia
    Li, TQ
    Takahashi, AM
    Hindmarsh, T
    Moseley, ME
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 143 - 147
  • [9] Single-shot ultrafast optical imaging
    Liang, Jinyang
    Wang, Lihong V.
    OPTICA, 2018, 5 (09): : 1113 - 1127
  • [10] Single-Shot High-Density Volumetric Particle Imaging Enabled by Differentiable Holography
    Wu, Yang
    Wang, Jun
    Thoroddsen, Sigurdur T.
    Chen, Ni
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2024, 20 (12) : 13696 - 13706