Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI
被引:50
|作者:
Wilm, Bertram J.
[1
,2
]
Barmet, Christoph
[1
,2
,3
]
Gross, Simon
[1
,2
]
Kasper, Lars
[1
,2
,4
]
Vannesjo, S. Johanna
[1
,2
]
Haeberlin, Max
[1
,2
]
Dietrich, Benjamin E.
[1
,2
]
Brunner, David O.
[1
,2
]
Schmid, Thomas
[1
,2
]
Pruessmann, Klaas P.
[1
,2
]
机构:
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Skope Magnetic Resonance Technol Inc, Zurich, Switzerland
[4] Univ Zurich, Inst Biomed Engn, Translat Neuromodeling Unit, Zurich, Switzerland
关键词:
single-shot spiral;
algebraic image reconstruction;
magnetic field monitoring;
magnetic field probes;
DWI;
DTI;
OFF-RESONANCE CORRECTION;
K-SPACE TRAJECTORIES;
MAGNETIC-FIELD FLUCTUATIONS;
QUANTITATIVE CHARACTERIZATION;
RECONSTRUCTION;
ECHO;
SEPARATION;
TENSOR;
ACQUISITION;
ARTIFACTS;
D O I:
10.1002/mrm.26493
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
PurposeThe purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. MethodsImage formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B-0, and coil sensitivity encoding. The encoding model is determined by B-0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. ResultsUsing the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. ConclusionUse of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.