Reprint of: Flow and Heat Transfer Characteristics of the Mist/Steam Two-Phase Flow Cooling the Rectangular Channel with Column-Row-Ribs

被引:3
|
作者
Jiang, Guangwen [1 ,2 ]
Gao, Jianmin [1 ,2 ]
Shi, Xiaojun [1 ]
Li, Fajing [1 ,2 ]
Xu, Liang [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Western China Inst Qual Sci & Technol, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Mist/steam two-phase flow; Internal cooling passage; Gas turbine blades; Column-row-ribs; Heat transfer non-uniformity; SQUARE CHANNEL; FRICTION CHARACTERISTICS; HORIZONTAL TUBE; FLUID-FLOW; BROKEN; PERFORMANCE; TRANSVERSE; BEHAVIOR; PASSAGE; STEAM;
D O I
10.1016/j.ijheatmasstransfer.2020.120236
中图分类号
O414.1 [热力学];
学科分类号
摘要
Using mist/steam two-phase flow by mixing a small amount of fine water droplets into steam as the working fluid for the internal cooling passages of blades and vanes is a promising cooling technology for future gas turbines. We proposed a new cooling channel roughed with the column-row-ribs to achieve higher cooling efficiency and better heat transfer uniformity. The heat transfer experiment was conducted to validate the effectiveness of our numerical method. Flow and heat transfer performance of mist/steam two-phase flow was investigated in channels of different gap ratios and in a column-row-ribbed channel with gap ratios of epsilon =0.177 under different working conditions. Comparing to the solid ribbed channel, the column-row-ribbed channels sacrifice the heat transfer performance to achieve better heat transfer uniformity. As epsilon larger than 0.264, the column-row-ribs have better thermal enhancement performance than the solid ribs. For the column-row-ribbed channel with gap ratio epsilon =0.177, the heat transfer effect increases with the Re number. But the thermal uniformity and the thermal enhancement of the channel decreases obviously. As the wall heat flux q rises from 3000W/m(2) to 40000W/m(2), the thermal enhancement factor F gradually increases. But the wall heat transfer becomes less even. Continuously increasing the mist/steam mass ratio will help to increase the heat transfer effect of the heated walls, so does the heat-transfer non-uniformity. Simply increasing the droplets diameter will decrease the thermal enhancement factor and increase the heat transfer non-uniformity at the same time. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Effect of heaving motion on two-phase flow in horizontal channel: Flow and heat transfer characteristics
    Zhou, Y. L.
    Chang, H.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 145
  • [22] THE EFFECT OF CHANNEL DIAMETER ON HEAT TRANSFER CHARACTERISTICS OF TWO-PHASE FLOW IN MICROCHANNELS
    Choo, Kyosung
    Trainer, Daniel
    Kim, Sung Jin
    PROCEEDINGS OF THE ASME/JSME 8TH THERMAL ENGINEERING JOINT CONFERENCE 2011, VOL 1 PTS A AND B, 2011, : 1039 - 1046
  • [23] Experimental Study on Heat Transfer Characteristics of Two-phase Flow in Square and Rectangular Channels
    Zhang, Jingzhi
    Zhang, Bo
    Cheng, Cheng
    An, Jun
    Lei, Li
    Zhou, Naixiang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (03): : 850 - 855
  • [24] Experimental Study on Heat Transfer Characteristics of Two-Phase Flow in Square and Rectangular Channels
    Zhang, Jingzhi
    Zhang, Bo
    Lei, Li
    Cheng, Cheng
    Xu, Jinjin
    Zhou, Naixiang
    ENERGIES, 2022, 15 (22)
  • [25] Effect of aspect ratio on the flow and heat transfer characteristics of mist/steam in rectangular ribbed channels
    Gao, Tieyu
    Zeng, Junxiong
    Li, Jun
    Gong, Jianying
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 72 (03) : 255 - 273
  • [26] Study on Flow and Heat Transfer Characteristics of Vapor-Liquid Two-Phase Flow in a Narrow Rectangular Channel With Longitudinal Vortex Generators
    Huang, Yanping
    Huang, Jun
    Ma, Jian
    Wang, Qiuwang
    HEAT TRANSFER ENGINEERING, 2011, 32 (11-12) : 1053 - 1061
  • [27] Internal cooling passage of mist/steam two-phase flow enhanced cooling gas turbine blade
    Shi, Xiao-Jun
    Shui, Lin-Qi
    Gao, Jian-Min
    Li, Fa-Jing
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2015, 30 (11): : 2561 - 2567
  • [28] Effect of droplet characteristics and rotation speed on the flow and heat transfer characteristics of mist/air cooling in a rotating ribbed two-pass rectangular channel
    Wang, Xinjun
    Zhang, Feng
    Zheng, Daren
    Li, Jun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2017, 231 (02) : 119 - 132
  • [29] Flow boiling heat transfer characteristics of two-phase flow in microchannels
    Guo, Lei
    Zhang, Shusheng
    Hu, Jing
    AIP ADVANCES, 2022, 12 (05)
  • [30] Instability of a two-phase flow in a rectangular channel
    Chinnov, E. A.
    Guzanov, V. V.
    Kabov, O. A.
    TECHNICAL PHYSICS LETTERS, 2009, 35 (07) : 653 - 656