Detrimental Effect of Electromagnetic Pulse Exposure on Permeability of In Vitro Blood-brain-barrier Model

被引:33
作者
Zhou Jia Xing [1 ]
Ding Gui Rong [1 ]
Zhang Jie [1 ]
Zhou Yong Chun [1 ]
Zhang Yan Jun [1 ]
Guo Guo Zhen [1 ]
机构
[1] Fourth Mil Med Univ, Prevent Med Coll, Dept Radiat Med, Xian 710032, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Electromagnetic pulse; Blood-brain-barrier; Permeability; TEER; HRP; ZO-1; Claudin-5; WHOLE-BODY EXPOSURE; ENDOTHELIAL-CELLS; FIELDS; FREQUENCY; CULTURES; ALTER; PHONE; RATS;
D O I
10.3967/0895-3988.2013.02.007
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Objective To study the effect of electromagnetic pulse (EMP) exposure on permeability of in vitro blood-brain-barrier (BBB) model. Methods An in vitro BBB model, established by co-culturing brain microvascular endothelial cells (BMVEC) and astroglial cells (AC) isolated from rat brain, was exposed to EMP at 100 kV/m and 400 kV/m, respectively. Permeability of the model was assayed by measuring the transendothelial electrical resistance (TEER) and the horseradish peroxidase (HRP) transmission at different time points. Levels of BBB tight junction- related proteins were measured at 0, 1, 2, 4, 8, 12, 16, 20, 24 h after EMP exposure by Western blotting. Results The TEER level was lower in BBB model group than in control group at 12 h after EMP, exposure which returned to its normal level at 24 h. The 24 h recovery process was triphasic and biphasic respectively after EMP exposure at 100 kV/m and 400 kV/m. Following exposure to 400 kV/m EMP, the HRP permeability increased at 1-12 h and returned to its normal level at 24 h. Western blotting showed that the claudin-5 and ZO-1 protein levels were changed after EMP exposure. Conclusion EMP exposure at 100 kV/m and 400 kV/m can increase the permeability of in vitro BBB model and BBB tight junction-related proteins such as ZO-1 and claudin-5 may change EMP-induced BBB permeability.
引用
收藏
页码:128 / 137
页数:10
相关论文
共 43 条
[1]  
ABBOTT NJ, 1992, J CELL SCI, V103, P23
[2]   Single domain antibodies as blood-brain barrier delivery vectors [J].
Abulrob, A ;
Zhang, JB ;
Tanha, J ;
MacKenzie, R ;
Stanimirovic, D .
DRUG TRANSPORT(ERS) AND THE DISEASED BRAIN, 2005, 1277 :212-223
[3]  
ADAIR RK, 1995, AVIAT SPACE ENVIR MD, V66, P792
[4]   Pulsed high-frequency electromagnetic field affects human sleep and sleep electroencephalogram [J].
Borbély, AA ;
Huber, R ;
Graf, T ;
Fuchs, B ;
Gallmann, E ;
Achermann, P .
NEUROSCIENCE LETTERS, 1999, 275 (03) :207-210
[5]  
Brightman MW, 1969, CELL TISSUE RES, V198, P65
[6]   DNA damage in frog erythrocytes after in vitro exposure to a high peak-power pulsed electromagnetic field [J].
Chemeris, NK ;
Gapeyev, AB ;
Sirota, NP ;
Gudkova, OY ;
Kornienko, NV ;
Tankanag, AV ;
Konovalov, IV ;
Buzoverya, ME ;
Suvorov, VG ;
Logunov, VA .
MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2004, 558 (1-2) :27-34
[7]   Blood-brain barrier and electromagnetic fields:: Effects of scopolamine methylbromide on working memory after whole-body exposure to 2.45 GHz microwaves in rats [J].
Cosquer, B ;
de Vasconcelos, AP ;
Fröhlich, J ;
Cassel, JC .
BEHAVIOURAL BRAIN RESEARCH, 2005, 161 (02) :229-237
[8]   Whole-body exposure to 2.45 GHz electromagnetic fields does not alter anxiety responses in rats: a plus-maze study including test validation [J].
Cosquer, B ;
Galani, R ;
Kuster, N ;
Cassel, JC .
BEHAVIOURAL BRAIN RESEARCH, 2005, 156 (01) :65-74
[9]   Proteoglycan synthesis in bovine articular cartilage explants exposed to different low-frequency low-energy pulsed electromagnetic fields [J].
De Mattei, M. ;
Fini, M. ;
Setti, S. ;
Ongaro, A. ;
Gemmati, D. ;
Stabellini, G. ;
Pellati, A. ;
Caruso, A. .
OSTEOARTHRITIS AND CARTILAGE, 2007, 15 (02) :163-168
[10]   Effects of magnetic field exposure on open field behaviour and nociceptive responses in mice [J].
Del Seppia, C ;
Mezzasalma, L ;
Chloeris, E ;
Luschi, P ;
Ghione, S .
BEHAVIOURAL BRAIN RESEARCH, 2003, 144 (1-2) :1-9