A conceptual study on air jet-induced swirling plume for performance improvement of natural draft cooling towers

被引:40
作者
Lu, Yuanshen [1 ]
Klimenko, Alexander [1 ]
Russell, Hugh [1 ]
Dai, Yuchen [1 ]
Warner, John [2 ]
Hooman, Kamel [1 ]
机构
[1] Univ Queensland, Sch Mech & Min Engn, Brisbane, Qld 4072, Australia
[2] Jord Int, Sydney, NSW, Australia
关键词
Natural draft cooling towers; Vortex cooling tower; Cooling enhancement; Swirling plume; Updraft vortex; Power cycle efficiency; VERTICAL DELTA RADIATORS; THERMAL POWER-PLANT; NUMERICAL-SIMULATION; CROSSWIND CONDITION; WINDBREAK WALL; FLOW; ENHANCEMENT; WATER; EFFICIENCY; SYSTEM;
D O I
10.1016/j.apenergy.2018.02.095
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In thermal power cycles including concentrating solar thermal (CST) plants, natural draft cooling towers (NDCTs) are widely used heat-dumping facilities. One inherent drawback of NDCTs is that their cooling performance can be compromised by changes in ambient conditions, particularly temperature, which inevitably reduces the net power output of the cycles. Current methods resolving this issue are limited in a few options including inlet air pre-cooling, exit air heating, and fan assistance, each with considerable operational or initial cost. To more economically reduce energy efficiency losses of the power cycles due to inefficient cooling, this paper proposes a new concept of swirling plume method for both dry- and wet-type NDCTs. The method is to rotate the plume strongly like a tornado in the tower upper part and above the towers to increase the overall tower updraft capacity (pressure). The swirling plume is induced by high-speed air jets distributed at certain locations using a much smaller flow rate. A numerical investigation on a 20 m-tall dry-type NDCT model has been conducted verifying that this concept increases the airflow and the water temperature drop of the heat exchanger by at least 53.6% and 3.57 degrees C (39.2%), respectively, under 35 degrees C ambient temperature. This cooling performance enhancement enables a half megawatt-scale sCO(2)-based CST power cycle to recover its net power output, by 4.98%, to the level almost same as that at 30 degrees C ambient temperature. The air jet to create such a swirling plume consumes only 1/7 of the recovered power roughly. Compared with a traditional fan-forced cooler working under exactly the same condition, this concept requires significantly smaller energy in long-term operations as it would run only during temperature extremes. A simplified analytical modelling has found that the cooling tower performance is improved due to that the swirling plume creates an equivalent extra draft height on top of the tower which is attributed to two different vortical effects. The overall angular momentum of the swirl is a critical factor in these effects.
引用
收藏
页码:496 / 508
页数:13
相关论文
共 43 条
  • [1] A. Inc, 2011, FLUENT US GUID, V2011
  • [2] Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup
    Alavi, Seyed Rashid
    Rahmati, Mehdi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2016, 122 : 504 - 514
  • [3] Numerical simulation of water spray in natural draft dry cooling towers with a new nozzle representation approach
    Alkhedhair, Abdullah
    Jahn, Ingo
    Gurgenci, Hal
    Guan, Zhiqiang
    He, Suoying
    Lu, Yuanshen
    [J]. APPLIED THERMAL ENGINEERING, 2016, 98 : 924 - 935
  • [4] Boulay RB, 2005, Proceedings of the ASME Power Conference 2005, Pts A and B, P167
  • [5] Performance improvement of natural draft dry cooling system by interior and exterior windbreaker configurations
    Chen, Lei
    Yang, Lijun
    Du, Xiaoze
    Yang, Yongping
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 96 : 42 - 63
  • [6] An estimation of the performance limits and improvement of dry cooling on trough solar thermal plants
    Deng, Huifang
    Boehm, Robert F.
    [J]. APPLIED ENERGY, 2011, 88 (01) : 216 - 223
  • [7] USE OF ORIENTED SPRAY NOZZLES TO SET THE VAPOR-AIR FLOW IN ROTARY MOTION IN THE SUPERSPRAY SPACE OF THE EVAPORATIVE CHIMNEY-TYPE TOWER
    Dobrego, K. V.
    Davydenko, V. F.
    Koznacheev, I. A.
    [J]. JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2016, 89 (01) : 157 - 166
  • [8] Eugene Grindle JC, 2002, 2002 INT JOINT POW G
  • [9] Evaporative cooling of water in a mechanical draft cooling tower
    Fisenko, SP
    Brin, AA
    Petruchik, AI
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (01) : 165 - 177
  • [10] Evaporative cooling of water in a natural draft cooling tower
    Fisenko, SP
    Petruchik, AI
    Solodukhin, AD
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (23) : 4683 - 4694