Advanced Two Media (ATM) method for measurement of linear attenuation coefficient

被引:6
作者
Gupta, Manoj Kumar [1 ]
Sidhu, Baltej Singh [1 ]
Mann, K. S. [1 ]
Dhaliwal, A. S. [1 ]
Kahlon, K. S. [1 ]
机构
[1] Deemed Univ, St Longowal Inst Engn & Technol, Dept Phys, Sangrur 148106, Punjab, India
关键词
Linear attenuation coefficient; Advanced Two Media method; EFFECTIVE ATOMIC NUMBERS; ELECTRON-DENSITIES; MASS; SAMPLES; BARITE; FE; CR;
D O I
10.1016/j.anucene.2013.01.032
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Linear attenuation coefficient of irregular targets having unknown thickness (La, Pr, Nd, Gd, Tb, Ho and Er) and regular targets of known thickness (Mo, Ag, Sn, Wand Pb) at 59.54 keV have been measured by using a new technique named Advanced Two Media (ATM) method. In this modified Advanced Two Media method pure metallic foils have been used as a mediums 1 and 2. The obtained results from Advanced Two Media method and transmission geometry are in good agreement with theoretical values of WinXCOM. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:251 / 254
页数:4
相关论文
共 28 条
  • [1] Simplified two media method: A modified approach for measuring linear attenuation coefficient of odd shaped archaeological samples of unknown thickness
    Sidhu, Baltej Singh
    Dhaliwal, A. S.
    Mann, K. S.
    Kahlon, K. S.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (10) : 1516 - 1520
  • [2] Measurement of attenuation coefficient, effective atomic number and electron density of oxides of lanthanides by using simplified ATM-method
    Singh, Gurinderjeet
    Gupta, Manoj Kumar
    Dhaliwal, A. S.
    Kahlon, K. S.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2015, 619 : 356 - 360
  • [3] A Novel Hierarchical Extreme Machine-Learning-Based Approach for Linear Attenuation Coefficient Forecasting
    Varone, Giuseppe
    Ieracitano, Cosimo
    Ciftcioglu, Aybike Ozyuksel
    Hussain, Tassadaq
    Gogate, Mandar
    Dashtipour, Kia
    Al-Tamimi, Bassam Naji
    Almoamari, Hani
    Akkurt, Iskender
    Hussain, Amir
    ENTROPY, 2023, 25 (02)
  • [4] A calibration transmission method to determine the gamma-ray linear attenuation coefficient without a collimator
    Byun, Jong-In
    Yun, Ju-Yong
    APPLIED RADIATION AND ISOTOPES, 2015, 102 : 70 - 73
  • [5] A generalized method of converting CT image to PET linear attenuation coefficient distribution in PET/CT imaging
    王璐
    武丽伟
    魏乐
    高娟
    孙翠丽
    柴培
    李道武
    Chinese Physics B, 2014, 23 (02) : 507 - 515
  • [6] A generalized method of converting CT image to PET linear attenuation coefficient distribution in PET/CT imaging
    Wang Lu
    Wu Li-Wei
    Wei Le
    Gao Juan
    Sun Cui-Li
    Chai Pei
    Li Dao-Wu
    CHINESE PHYSICS B, 2014, 23 (02)
  • [7] Measurement of Linear-attenuation Coefficient of Body Source Using Non-collimated Point Source Transmission Approach
    Kadier A.
    Zhang L.
    Le F.
    Kang R.
    Silafuli T.
    Guo Q.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (06): : 1140 - 1147
  • [8] Linear and mass attenuation coefficient for CdTe compound of X-rays from 10 to 100 keV energy range in different phases
    Saim, A.
    Tebboune, A.
    Berkok, H.
    Belameiri, N.
    Belbachir, A. H.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2014, 602 : 261 - 264
  • [9] Measurement of the linear attenuation coefficient of breast tissues using polienergetic x-ray for energies from 12 to 50 keV and a silicon dispersive detector
    Soares, L. D. H.
    Gobo, M. S. S.
    Poletti, M. E.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [10] VELOCITY AND ATTENUATION OF LINEAR WAVES IN POROUS MEDIA SATURATED WITH GAS AND ITS HYDRATE
    Gubaidullin, A. A.
    Boldyreva, O. Yu
    Dudko, D. N.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2022, 63 (04) : 599 - 605