Anion exchange membrane adsorbers for flow-through polishing steps: Part II. Virus, host cell protein, DNA clearance, and antibody recovery

被引:65
作者
Weaver, Justin [1 ]
Husson, Scott M. [2 ]
Murphy, Louise [1 ]
Wickramasinghe, S. Ranil [1 ,3 ]
机构
[1] Colorado State Univ, Dept Chem & Biol Engn, Ft Collins, CO 80523 USA
[2] Clemson Univ, Dept Chem & Biomol Engn, Clemson, SC USA
[3] Univ Arkansas, Ralph E Martin Dept Chem Engn, Fayetteville, AR 72701 USA
基金
美国国家科学基金会;
关键词
membrane chromatography; purification; biopharmaceuticals; bioseparations; monoclonal antibody; protein purification; CHROMATOGRAPHY; PURIFICATION;
D O I
10.1002/bit.24724
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Anion exchange membrane adsorbers are used for contaminant removal in flow-through polishing steps in the manufacture of biopharmaceuticals. This contribution describes the clearance of minute virus of mice, DNA, and host cell proteins by three commercially available anion-exchange membranes: Sartobind Q, Mustang Q, and ChromaSorb. The Sartobind Q and Mustang Q products contain quaternary amine ligands; whereas, ChromaSorb contains primary amine based ligands. Performance was evaluated over a range of solution conditions: 0200?mM NaCl, pH 6.09.0, and flow rates of 420?membrane?volumes/min in the presence and absence of up to 50?mM phosphate and acetate. In addition contaminant clearance was determined in the presence and absence of 5?g/L monoclonal antibody. The quaternary amine based ligands depend mainly on Coulombic interactions for removal of negatively charged contaminants. Consequently, performance of Sartobind Q and Mustang Q was compromised at high ionic strength. Primary amine based ligands in ChromaSorb enable high capacities at high ionic strength due to the presence of secondary, hydrogen bonding interactions. However, the presence of hydrogen phosphate ions leads to reduced capacity. Monoclonal antibody recovery using primary amine based anion-exchange ligands may be lower if significant binding occurs due to secondary interactions. The removal of a specific contaminant is affected by the level of removal of the other contaminants. The results of this study may be used to help guide selection of commercially available membrane absorbers for flow-through polishing steps. Biotechnol. Bioeng. 2013; 110: 500510. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:500 / 510
页数:11
相关论文
共 16 条
[1]   The cytotoxicity of the parvovirus minute virus of mice nonstructural protein NS1 is related to changes in the synthesis and phosphorylation of cell proteins [J].
Anouja, F ;
Wattiez, R ;
Mousset, S ;
CailletFauquet, P .
JOURNAL OF VIROLOGY, 1997, 71 (06) :4671-4678
[2]   Membrane adsorbers as purification tools for monoclonal antibody purification [J].
Boi, Cristiana .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (01) :19-27
[3]   Microcalorimetric studies on the adsorption of DNA by soil colloidal particles [J].
Cai, Peng ;
Huang, Qiaoyun ;
Jiang, Daihua ;
Rong, Xingmin ;
Liang, Wei .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2006, 49 (01) :49-54
[4]  
Curling J, 2007, BIOPHARM INT, P10
[5]   Profiling of Host Cell Proteins by Two-Dimensional Difference Gel Electrophoresis (2D-DIGE): Implications for Downstream Process Development [J].
Jin, Mi ;
Szapiel, Nicolas ;
Zhang, Jennifer ;
Hickey, John ;
Ghose, Sanchayita .
BIOTECHNOLOGY AND BIOENGINEERING, 2010, 105 (02) :306-316
[6]   Preparation and characterization of prototypes for multi-modal separation media aimed for capture of negatively charged biomolecules at high salt conditions [J].
Johansson, BL ;
Belew, M ;
Eriksson, S ;
Glad, G ;
Lind, O ;
Maloisel, JL ;
Norrman, N .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) :21-33
[7]   Affinity membranes: a 10-year review [J].
Klein, E .
JOURNAL OF MEMBRANE SCIENCE, 2000, 179 (1-2) :1-27
[8]   Membrane ion-exchange chromatography for process-scale antibody purification [J].
Knudsen, HL ;
Fahrner, RL ;
Xu, Y ;
Norling, LA ;
Blank, GS .
JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) :145-154
[9]   Evaluation of an anion-exchange hollow-fiber membrane adsorber containing γ-ray grafted glycidyl methacrylate chains [J].
Shirataki, Hironobu ;
Sudoh, Chie ;
Eshima, Takamitsu ;
Yokoyama, Yoshiro ;
Okuyama, Kazuo .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (17) :2381-2388
[10]  
Weaver J, 2012, BIOTECHNOL BIO UNPUB