Whole blood analysis using microfluidic plasma separation and enzyme-linked immunosorbent assay devices

被引:10
作者
Shimizu, Hisashi [1 ]
Kumagai, Mariko [1 ]
Mori, Emi [1 ]
Mawatari, Kazuma [1 ]
Kitamori, Takehiko [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
基金
日本科学技术振兴机构;
关键词
MICROCHIP; SAMPLE; CELLS; IMMUNOASSAY; PLATFORM; SYSTEM; SHEAR; CHIP; FLOW;
D O I
10.1039/c6ay01779g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a microfluidic plasma-separation device that realizes the whole blood analysis of C-reactive protein (CRP) using one drop of blood is developed. A small, fast, and easy-to-operate blood-testing device is desirable for point-of-care testing, home medical care, and medical cost reduction. Recently, significant advances have been made in analytical instrumentation, and an enzyme-linked immunosorbent assay (ELISA) of a 1 mu L plasma sample has previously been realized. Moreover, recent developments in microfluidics have led to the miniaturization of analytical instruments. However, analytical centrifuges that are conventionally used for the separation of plasma and blood cells are very large and cumbersome to combine with microfluidic devices. Therefore, we propose a plasma-separation device combining microfluidics and membrane filtering. Herein, the proposed plasmaseparation device is applied to whole blood analysis using one drop of blood. Specifically, the device is designed and fabricated to realize high plasma-separation efficiency via the evaluation of fluidic resistance of a porous membrane. Then, the quality of the plasma separated using the device is evaluated and compared with that of the plasma separated using a conventional centrifuge. Our results reveal that the microfluidic plasma-separation device can efficiently provide a sample for the ELISA of CRP using one drop (50 mu L) of whole blood. The total analysis time including plasma separation and ELISA is approximately 25 min.
引用
收藏
页码:7597 / 7602
页数:6
相关论文
共 37 条
  • [1] Vesicles and red blood cells in shear flow
    Abkarian, Manouk
    Viallat, Annie
    [J]. SOFT MATTER, 2008, 4 (04) : 653 - 657
  • [2] AMATUZIO D S, 1962, Minn Med, V45, P378
  • [3] Microchip-based Plasma Separation from Whole Blood via Axial Migration of Blood Cells
    Aota, Arata
    Takahashi, Susumu
    Mawatari, Kazuma
    Tanaka, Yo
    Sugii, Yasuhiko
    Kitamori, Takehiko
    [J]. ANALYTICAL SCIENCES, 2011, 27 (12) : 1173 - 1178
  • [4] INTERACTIONS AMONG ERYTHROCYTES UNDER SHEAR
    BROOKS, DE
    GOODWIN, JW
    SEAMAN, GVF
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1970, 28 (02) : 172 - &
  • [5] A lab-on-a-chip for rapid blood separation and quantification of hematocrit and serum analytes
    Browne, Andrew W.
    Ramasamy, Lakshminarayanan
    Cripe, Timothy P.
    Ahn, Chong H.
    [J]. LAB ON A CHIP, 2011, 11 (14) : 2440 - 2446
  • [6] Gravitational field-flow fractionation integrated with chemiluminescence detection for a self-standing point-of-care compact device in bioanalysis
    Casolari, S.
    Roda, B.
    Mirasoli, M.
    Zangheri, M.
    Patrono, D.
    Reschiglian, P.
    Roda, A.
    [J]. ANALYST, 2013, 138 (01) : 211 - 219
  • [7] Development of a multilayer microfluidic device integrated with a PDMS-cellulose composite film for sample pre-treatment and immunoassay
    Chen, Xing
    Zhang, Lulu
    Li, Hui
    Sun, Jianhan
    Cai, Haoyuan
    Cui, Dafu
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2013, 193 : 54 - 58
  • [8] Nuclear track microfilters:: gas separation ability and β-radiation stability
    Ensinger, W
    Vater, P
    Happel, S
    Sudowe, R
    Brandt, R
    [J]. RADIATION MEASUREMENTS, 2003, 36 (1-6) : 707 - 711
  • [9] Faivre M, 2006, BIORHEOLOGY, V43, P147
  • [10] Integrated barcode chips for rapid, multiplexed analysis of proteins in microliter quantities of blood
    Fan, Rong
    Vermesh, Ophir
    Srivastava, Alok
    Yen, Brian K. H.
    Qin, Lidong
    Ahmad, Habib
    Kwong, Gabriel A.
    Liu, Chao-Chao
    Gould, Juliane
    Hood, Leroy
    Heath, James R.
    [J]. NATURE BIOTECHNOLOGY, 2008, 26 (12) : 1373 - 1378