Accuracy of presepsin in neonatal sepsis: systematic review and meta-analysis

被引:27
作者
Parri, Niccolo [1 ,2 ]
Trippella, Giulia [3 ]
Lisi, Catiuscia [4 ]
De Martino, Maurizio [5 ]
Galli, Luisa [6 ]
Chiappini, Elena [6 ]
机构
[1] Meyer Univ, Childrens Hosp, Dept Emergency Med, Florence, Italy
[2] Meyer Univ, Childrens Hosp, Trauma Ctr, Florence, Italy
[3] Univ Florence, Meyer Univ, Childrens Hosp, Dept Sci Woman & Childs Hlth, Florence, Italy
[4] Univ Florence, Dept Stat, Florence, Italy
[5] Univ Florence, Dept Sci Woman & Childs Hlth, Florence, Italy
[6] Univ Florence, Meyer Univ, Childrens Hosp, Div Pediat Infect Dis,Dept Hlth Sci, Florence, Italy
关键词
Presepsin; neonates; neonatal sepsis; biomarkers; sepsis diagnosis; diagnostic accuracy; CD14 SUBTYPE SCD14-ST; C-REACTIVE PROTEIN; DIAGNOSTIC-VALUE; ONSET SEPSIS; PROCALCITONIN; HETEROGENEITY; BIOMARKERS; NEWBORNS;
D O I
10.1080/14787210.2019.1584037
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Introduction: Neonatal sepsis represents a major cause of morbidity and mortality in neonates. No diagnostic test has been demonstrated to be sufficiently accurate to confirm or exclude neonatal sepsis. This study aimed to evaluate the diagnostic accuracy of presepsin (P-SEP) for neonatal sepsis. Areas covered: A systematic review of literature was performed on Medline and EMBASE. A meta-analysis was performed to calculate pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic of P-SEP for neonatal sepsis. Eight studies were included, involving 636 neonates. Pooled sensitivity and specificity were 0.90 and 0.90, respectively. The pooled DOR was 120.94, and the Area Under Curve (AUC) was 0.968, indicating a high level of diagnostic accuracy. Using cut-off values <600 ng/L, sensitivity reached 0.93, with a specificity of 0.81 and AUC 0.8195, while using a threshold >600 ng/L, sensitivity was 0.87 and specificity 0.97, with higher diagnostic accuracy (AUC 0.976). Significant heterogeneity was found between studies. Expert commentary: Diagnostic accuracy of P-SEP resulted high in detecting neonatal sepsis. Even though it cannot be recommended as a single diagnostic test, P-SEP could be a helpful and valuable biomarker in neonates with suspected sepsis.
引用
收藏
页码:223 / 232
页数:10
相关论文
共 52 条
[1]  
[Anonymous], PEDIAT NEONATOL
[2]  
[Anonymous], 2015, J AM SCI
[3]  
[Anonymous], 2015, IJRSB
[4]   Understanding heterogeneity in meta-analysis: the role of meta-regression [J].
Baker, W. L. ;
White, C. Michael ;
Cappelleri, J. C. ;
Kluger, J. ;
Coleman, C. I. .
INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2009, 63 (10) :1426-1434
[5]   OPERATING CHARACTERISTICS OF A BANK CORRELATION TEST FOR PUBLICATION BIAS [J].
BEGG, CB ;
MAZUMDAR, M .
BIOMETRICS, 1994, 50 (04) :1088-1101
[6]   The diagnostic accuracy of presepsin in neonatal sepsis: a meta-analysis [J].
Bellos, Ioannis ;
Fitrou, Georgia ;
Pergialiotis, Vasilios ;
Thomakos, Nikolaos ;
Perrea, Despina N. ;
Daskalakis, Georgios .
EUROPEAN JOURNAL OF PEDIATRICS, 2018, 177 (05) :625-632
[7]   DEFINITIONS FOR SEPSIS AND ORGAN FAILURE AND GUIDELINES FOR THE USE OF INNOVATIVE THERAPIES IN SEPSIS [J].
BONE, RC ;
BALK, RA ;
CERRA, FB ;
DELLINGER, RP ;
FEIN, AM ;
KNAUS, WA ;
SCHEIN, RMH ;
SIBBALD, WJ .
CHEST, 1992, 101 (06) :1644-1655
[8]   A hands-on practical tutorial on performing meta-analysis with Stata [J].
Chaimani, Anna ;
Mavridis, Dimitris ;
Salanti, Georgia .
EVIDENCE-BASED MENTAL HEALTH, 2014, 17 (04) :111-116
[9]  
Chen LP, 2017, INT J CLIN EXP PATHO, V10, P9718
[10]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188