Glasses-Assisted 3D Display System-Guided Descemet Membrane Endothelial Keratoplasty Tissue Preparation

被引:4
作者
Borroni, Davide [1 ,2 ]
Rocha-de-Lossada, Carlos [3 ,4 ,5 ]
Bonci, Paola [6 ]
Rechichi, Miguel [7 ]
Rodriguez-Calvo-de-Mora, Marina [3 ,8 ]
Rachwani-Anil, Rahul [9 ]
Sanchez Gonzalez, Jose' Maria [10 ]
Urbinati, Facundo [8 ]
Garcia Lorente, Maria [8 ]
Vigo, Luca [2 ]
Carones, Francesco [2 ]
机构
[1] Riga Stradins Univ, Dept Doctoral Studies, Riga, Latvia
[2] Advalia Vis, Cornea Res Unit, Milan, Italy
[3] Qvis Vithas Almeria, Dept Ophthalmol, Granada, Spain
[4] Univ Hosp Virgen de Las Nieves, Granada, Spain
[5] Ceuta Med Ctr, Dept Ophthalmol, Ceuta, Spain
[6] Banca Cornee Reg Emilia Romagna, Osped Civile Ravenna, Sellia Marina, Italy
[7] Ctr Polispecialist Mediterraneo, Sellia Marina, Italy
[8] Reg Univ Hosp Malaga, Malaga 29010, Spain
[9] Hosp Antequera, Dept Opthalmol, Malaga, Spain
[10] Opt Area Univ Seville, Dept Phys Condensed Matter, Seville, Spain
关键词
DMEK; 3D display system; stripping;
D O I
10.1097/ICO.0000000000003005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to evaluate the feasibility of Descemet membrane endothelial keratoplasty (DMEK) tissue preparation using a glasses-assisted 3-dimensional (3D) display system and to compare it with a conventional surgical microscope. Methods: Healthy pairs of human corneas suitable for penetrating keratoplasty surgery were selected for this study. The tissues were randomly divided into 2 groups. Each pair of corneas had 1 cornea (group 1) prepared with NGENUITY (Alcon) with a 5-second staining time with vision blue, and the fellow cornea (group 2) was prepared using a OPMI Lumera 700 surgical microscope (Carl Zeiss Meditec, Jena, Germany) with a 30-second staining time. DMEK graft preparation time, speed of stripping, graft width, and endothelial cell loss were evaluated. Results: Twenty-eight pairs of corneas were included in this study. The graft preparation time was significantly higher in the 3D group than in the conventional group (498 +/- 147 vs. 418 +/- 85 seconds, P value = 0.031). The mean speed of stripping was 0.59 +/- 0.081 mm/s in group 1 and 0.089 +/- 0.005 mm/s in group 2 (P value = 0.024). The mean endothelial cell density in group 1 and group 2 before tissue preparation was 2162 +/- 115.21 and 2153 +/- 122.45, respectively (P value > 0.1). After tissue preparation, the endothelial cell density reduced to 1911 +/- 150.72 in group 1 and 1998 +/- 90.72 in group 2 (P value = P value > 0.05). The graft width was 5.05 +/- 0.71 mm in group 1 and 4.92 +/- 0.23 mm in group 2 (P value > 0.05). Conclusions: DMEK tissue preparation with 3D display system NGENUITY is feasible with a slightly increased preparation time. The improved visualization allows a reduced staining time that could be beneficial for eye banks because it may reduce the toxic effect of staining colorants.
引用
收藏
页码:1444 / 1446
页数:3
相关论文
共 26 条
  • [1] The Influence of Speed During Stripping in Descemet Membrane Endothelial Keratoplasty Tissue Preparation
    Borroni, Davide
    Gadhvi, Kunal
    Wojcik, Gabriela
    Pennisi, Flavia
    Vallabh, Neeru A.
    Galeone, Alessandra
    Ruzza, Alessandro
    Arbabi, Esmaeil
    Menassa, Nardine
    Kaye, Stephen
    Ponzin, Diego
    Ferrari, Stefano
    Romano, Vito
    [J]. CORNEA, 2020, 39 (09) : 1086 - 1090
  • [2] A Novel Virtual Wet Lab-Using a Smartphone Camera Adapter and a Video Conference Platform to Provide Real-Time Surgical Instruction
    Cervantes, Lorenzo J.
    Tallo, Christian A.
    Lopes, Caithlin A.
    Hellier, Erik A.
    Chu, David S.
    [J]. CORNEA, 2021, 40 (12) : 1639 - 1643
  • [3] Trephine- and dye-free technique for eye bank preparation of pre-stripped Descemet membrane endothelial keratoplasty tissue
    Chamani, Tahereh
    Javadi, Mohammad Ali
    Kanavi, Mozhgan Rezaei
    [J]. CELL AND TISSUE BANKING, 2019, 20 (02) : 321 - 326
  • [4] Viability of preloaded Descemet membrane endothelial keratoplasty grafts with 96-hour shipment
    Chen, Conan
    Solar, Steven Jared
    Lohmeier, John
    Terrin, Staci
    Baliga, Satya
    Wiener, Batya Gold
    Lewis, Daniel Schouten
    Chiang, Eric
    Barnes, Kali Alexandra
    Chaurasia, Akash
    Eghrari, Allen O.
    [J]. BMJ OPEN OPHTHALMOLOGY, 2021, 6 (01):
  • [5] Patent Blue V as an Alternative Stain for DMEK Grafts: Safety, Stain Retention, and Feasibility
    Chen, Shin-Yi
    Tran, Khoa D.
    Wehrer, Stephen
    Potts, Luke B.
    Bauer, Alex J.
    Straiko, Michael D.
    Terry, Mark A.
    [J]. CORNEA, 2019, 38 (10) : 1322 - 1327
  • [6] Heads-up 3D eye surgery: Safety outcomes and technological review after 2 years of day-to-day use
    Del Turco, Claudia
    D'Amico Ricci, Giuseppe
    Dal Vecchio, Marco
    Bogetto, Caterina
    Panico, Edoardo
    Giobbio, Dora Cecilia
    Romano, Mario R.
    Panico, Claudio
    La Spina, Carlo
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 1129 - 1135
  • [7] DSAEK Centration and Interface Folds: Surgical Management
    Gadhvi, Kunal
    Pagano, Luca
    Menassa, Nardine
    Borroni, Davide
    Kaye, Stephen B.
    Levis, Hannah J.
    Romano, Vito
    [J]. CORNEA, 2020, 39 (11) : 1457 - 1459
  • [8] Galvis V, 2017, J SURG CASE REP, DOI 10.1093/jscr/rjx231
  • [9] Can the Three-Dimensional Heads-Up Display Improve Ergonomics, Surgical Performance, and Ophthalmology Training Compared to Conventional Microscopy?
    Helayel, Halah Bin
    Al-Mazidi, Sarah
    Alakeely, Adel
    [J]. CLINICAL OPHTHALMOLOGY, 2021, 15 : 679 - 686
  • [10] Corneal pachymetry by AS-OCT after Descemet's membrane endothelial keratoplasty
    Heslinga, Friso G.
    Lucassen, Ruben T.
    van den Berg, Myrthe A.
    van der Hoek, Luuk
    Pluim, Josien P. W.
    Cabrerizo, Javier
    Alberti, Mark
    Veta, Mitko
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)