Radiological and clinical differences between robotic-assisted pedicle screw fixation with and without real-time optical tracking

被引:8
作者
Du, Jinpeng [1 ]
Gao, Lin [1 ]
Huang, Dageng [1 ]
Shan, Lequn [1 ]
Wang, Wentao [1 ]
Fan, Yong [1 ]
Hao, Dingjun [1 ]
Yan, Liang [1 ]
机构
[1] Xi An Jiao Tong Univ, Honghui Hosp, Dept Spine Surg, Friendship East Rd, Xian 710054, Shaanxi, Peoples R China
关键词
Tinavi; Robot; Renaissance; Screw fixation; Lumbar; Optical tracking; NAVIGATION SYSTEMS; ACCURACY; PLACEMENT; INSERTION; INSTRUMENTATION; TECHNOLOGIES;
D O I
10.1007/s00586-020-06641-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To study radiological and clinical differences between robotic-assisted pedicle screw fixation with and without real-time optical tracking. Methods Patients who underwent lumbar internal fixation in our hospital from June 2017 to February 2020 were divided into Tinavi group (with optical tracking) and Renaissance group (without optical tracking) according to assisted technology. The imaging data of the patients were collected, and the accuracy of screw implantation was measured according to Rampersaud A-D grade. Clinical outcomes such as operative time, fluoroscopic time and radiations dose were also collected. Results A total of 376 patients were included, including 201 patients in the Tinavi group with 968 screws implanted and 175 patients in the Renaissance group with 822 screws implanted. The accuracy of "perfect" and "clinically acceptable" pedicle screw implantation in the Tinavi group was 94.9%-98.7%, respectively, while in the Renaissance group was 91.2%-94.5%, respectively. There was significant difference between the two groups (P < 0.05). The operative time and operative time per screw in the Tinavi group were lower than those in the Renaissance group. However, fluoroscopic time per screw and radiations dose of the Tinavi group were significantly higher than those of the Renaissance group. Conclusion Optical tracking in robotic system appears to increase accuracy because of the ability to detect the real-time position of the patient. Although there are still many problems to be solved, robot with optical tracking system shows its great potential in clinical application.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 30 条
[21]   Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws A Prospective Randomized Comparison to Conventional Freehand Screw Implantation [J].
Ringel, Florian ;
Stueer, Carsten ;
Reinke, Andreas ;
Preuss, Alexander ;
Behr, Michael ;
Auer, Florian ;
Stoffel, Michael ;
Meyer, Bernhard .
SPINE, 2012, 37 (08) :E496-E501
[22]   Spinal Robotics: Current Applications and Future Perspectives [J].
Roser, Florian ;
Tatagiba, Marcos ;
Maier, Gottlieb .
NEUROSURGERY, 2013, 72 :A12-A18
[23]  
Schizas C, 2012, ACTA ORTHOP BELG, V78, P240
[24]   Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies [J].
Tian, Nai-Feng ;
Huang, Qi-Shan ;
Zhou, Ping ;
Zhou, Yang ;
Wu, Rui-Kai ;
Lou, Yi ;
Xu, Hua-Zi .
EUROPEAN SPINE JOURNAL, 2011, 20 (06) :846-859
[25]   Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study [J].
Tian, Wei ;
Liu, Yajun ;
Zheng, Shan ;
Lv, Yanwei .
EUROPEAN SPINE JOURNAL, 2013, 22 (01) :148-155
[26]   Pedicle screw placement accuracy of bone-mounted miniature robot system [J].
Tsai, Tai-Hsin ;
Tzou, Rong-Dar ;
Su, Yu-Feng ;
Wu, Chieh-Hsin ;
Tsai, Cheng-Yu ;
Lin, Chih-Lung .
MEDICINE, 2017, 96 (03)
[27]   CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws [J].
Waschke, Albrecht ;
Walter, Jan ;
Duenisch, Pedro ;
Reichart, Rupert ;
Kalff, Rolf ;
Ewald, Christian .
EUROPEAN SPINE JOURNAL, 2013, 22 (03) :654-660
[28]   Risk factors for robot-assisted spinal pedicle screw malposition [J].
Zhang, Jia Nan ;
Fan, Yong ;
Hao, Ding Jun .
SCIENTIFIC REPORTS, 2019, 9 (1)
[29]   Robotic navigation during spine surgery [J].
Zhang, Qi ;
Han, Xiao-Guang ;
Xu, Yun-Feng ;
Fan, Ming-Xing ;
Zhao, Jing-Wei ;
Liu, Ya-Jun ;
He, Da ;
Tian, Wei .
EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (01) :27-32
[30]   Robot-Assisted Versus Fluoroscopy-Guided Pedicle Screw Placement in Transforaminal Lumbar Interbody Fusion for Lumbar Degenerative Disease [J].
Zhang, Qi ;
Han, Xiao-Guang ;
Xu, Yun-Feng ;
Liu, Ya-Jun ;
Liu, Bo ;
He, Da ;
Sun, Yu-Qing ;
Tian, Wei .
WORLD NEUROSURGERY, 2019, 125 :E429-E434