Orbital mass lesions: US-guided fine-needle aspiration biopsy - Experience in 37 patients

被引:21
|
作者
Gupta, S [1 ]
Sood, B
Gulati, M
Takhtani, D
Bapuraj, R
Khandelwal, N
Singh, U
Rajwanshi, A
Gupta, S [1 ]
Suri, S
机构
[1] Postgrad Inst Med Educ & Res, Dept Radiodiag, Chandigarh 160012, India
[2] Postgrad Inst Med Educ & Res, Dept Ophthalmol, Chandigarh 160012, India
[3] Postgrad Inst Med Educ & Res, Dept Cytol, Chandigarh 160012, India
关键词
biopsies; orbit; CT; neoplasms; US; ultrasound; (US); guidance;
D O I
10.1148/radiology.213.2.r99nv24568
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the safety and effectiveness of using ultrasonographic (US) guidance for performing fine-needle aspiration biopsies of orbital mass lesions, MATERIALS AND METHODS: Thirty-seven patients with mass lesions in the orbit underwent US-guided fine-needle aspiration biopsy. Computed tomographic scans wet-e available in all patients. In 19 patients, the lesions were located in the posterior orbit, whereas in 18 patients the lesions were located in (n = 3) or extended up to (n = 15) the anterior compartment. Fine-needle aspiration biopsy was performed with 22-25-gauge needles and use of the freehand technique, RESULTS: Needle biopsies were performed safely and easily, and real-time US monitoring of the needle position was used to avoid injury to the eyeball. No major complications were encountered. Diagnostic specimens were obtained in 29 (78%) of the 37 patients, and 19 benign and 10 malignant disease processes were diagnosed. In eight patients (22%), an appropriate diagnosis could not be made, as aspiration samples yielded insufficient tissue. CONCLUSION: US provides safe and effective guidance for performing fine-needle aspiration biopsy in orbital mass lesions and is especially useful in deep-seated nonbalpable retrobulbar lesions.
引用
收藏
页码:568 / 572
页数:5
相关论文
共 50 条
  • [1] Evaluation of mediastinal lymphadenopathy with endoscopic US-guided fine-needle aspiration biopsy
    Wiersema, MJ
    Vazquez-Sequeiros, E
    Wiersema, LM
    RADIOLOGY, 2001, 219 (01) : 252 - 257
  • [2] MASSES IN BREASTS WITH IMPLANTS - DIAGNOSIS WITH US-GUIDED FINE-NEEDLE ASPIRATION BIOPSY
    FORNAGE, BD
    SNEIGE, N
    SINGLETARY, SE
    RADIOLOGY, 1994, 191 (02) : 339 - 342
  • [3] US-GUIDED FINE-NEEDLE ASPIRATION BIOPSY OF GALLBLADDER MASSES
    ZARGAR, SA
    KHUROO, MS
    MAHAJAN, R
    JAN, GM
    SHAH, P
    RADIOLOGY, 1991, 179 (01) : 275 - 278
  • [4] Breast intraductal masses: US-guided fine-needle aspiration after galactography
    Sardanelli, F
    Imperiale, A
    Zandrino, F
    Calabrese, M
    Bonifacio, A
    Canavese, G
    Nicolo, G
    RADIOLOGY, 1997, 204 (01) : 143 - 148
  • [5] Bowel lesions: Percutaneous US-guided 18-gauge needle biopsy - Preliminary experience
    Tudor, GR
    Rodgers, PM
    West, KP
    RADIOLOGY, 1999, 212 (02) : 594 - 597
  • [6] CT OR US-GUIDED FINE NEEDLE ASPIRATION BIOPSY IN GASTRIC NEOPLASMS
    BREE, RL
    MCGOUGH, MF
    SCHWAB, RE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) : 565 - 569
  • [7] Head and neck squamous cell carcinoma: US-guided fine-needle aspiration of sentinel lymph nodes for improved staging - Initial experience
    Colnot, DR
    Nieuwenhuis, EJC
    van den Brekel, MWM
    Pijpers, R
    Brakenhoff, RH
    Snow, GB
    Castelijns, JA
    RADIOLOGY, 2001, 218 (01) : 289 - 293
  • [8] Repeat US-guided Fine-Needle Aspiration Biopsy of Thyroid Nodules: Some Clarifications Are Needed Response
    Kwak, Jin Young
    Kim, Eun-Kyung
    RADIOLOGY, 2010, 257 (01) : 299 - 299
  • [9] Role of operator experience in ultrasound-guided fine-needle aspiration biopsy of the thyroid
    De Fiori, E.
    Rampinelli, C.
    Turco, F.
    Bonello, L.
    Bellomi, M.
    RADIOLOGIA MEDICA, 2010, 115 (04): : 612 - 618
  • [10] Free-hand technique with ordinary antisepsis in abdominal US-guided fine-needle punctures: Three-year experience
    Caturelli, E
    Giacobbe, A
    Facciorusso, D
    Villani, MR
    Squillante, MM
    Siena, DA
    Cellerino, C
    Andriulli, A
    RADIOLOGY, 1996, 199 (03) : 721 - 723