The performances of an electrochemical detector (ECD) using Prussian blue (PB) modified indium tin oxide (ITO) electrode were investigated. PB is one of the well-known catalytic materials. PB offers electrocatalytic reaction between electrode and analytes (dopamine and catechol). We optimized the PB film thickness that would catalyze redox reaction efficiently using surface topography from atomic force microscopy (AFM). Capillary electrophoresis (CE) and amperometric method were used to separate and detect the testing analytes. The results showed that the PB film could serve as an excellent mediator, which catalyzes electron transfer. We measured electropherograms for the testing analytes consisting of catechol and dopamine with their concentrations of 100 wM and 10 mu M, respectively.
引用
收藏
页码:746 / 749
页数:4
相关论文
共 7 条
[1]   Sensitivity and stability of porous polycrystalline silicon gas sensor [J].
Han, PG ;
Wong, H ;
Poon, MC .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2001, 179 (2-3) :171-175
[2]   Electrical contact of redox enzymes with electrodes: Novel approaches for amperometric biosensors [J].
Katz, E ;
HelegShabtai, V ;
Willner, B ;
Willner, I ;
Buckmann, AF .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01) :95-104
[3]   Development of a microfabricated disposable microchip with a capillary electrophoresis and integrated three-electrode electrochemical detection [J].
Kim, JH ;
Kang, CJ ;
Kim, YS .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2314-2317
[4]   A disposable capillary electrophoresis microchip with an indium tin oxide decoupler/amperometric detector [J].
Kim, JH ;
Kang, CJ ;
Jeon, D ;
Kim, YS .
MICROELECTRONIC ENGINEERING, 2005, 78-79 :563-570
[5]   In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat [J].
Martin, RS ;
Ratzlaff, KL ;
Huynh, BH ;
Lunte, SM .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1136-+
[6]   Recent developments in detection methods for microfabricated analytical devices [J].
Schwarz, MA ;
Hauser, PC .
LAB ON A CHIP, 2001, 1 (01) :1-6
[7]   Capillary electrophoresis chips with integrated electrochemical detection [J].
Woolley, AT ;
Lao, KQ ;
Glazer, AN ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1998, 70 (04) :684-688