Microextraction versus exhaustive extraction approaches for simultaneous analysis of compounds in wide range of polarity

被引:42
作者
Mirnaghi, Fatemeh S. [1 ]
Gorynski, Krzysztof [1 ]
Rodriguez-Lafuente, Angel [1 ]
Boyaci, Ezel [1 ]
Bojko, Barbara [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Microextraction; Exhaustive extraction; Solid phase microextraction; Solid phase extraction; Breakthrough volume; SOLID-PHASE MICROEXTRACTION; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; THIN-FILM MICROEXTRACTION; BIOLOGICAL-FLUIDS; BINDING; SYSTEM; RECEPTOR; SAMPLES; PLASMA;
D O I
10.1016/j.chroma.2013.09.084
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article discusses comparison of microextraction versus exhaustive extraction approaches for simultaneous extraction of compounds in wide range of polarity at low and high volumes of sample by comparing solid phase extraction (SPE) and solid phase microextraction (SPME). Here, both systems are discussed theoretically and evaluated based on experimental data. Experimental comparisons were conducted in terms of extraction recovery, sensitivity, and selectivity for the extraction of doping agent compounds (logP: 0.14-4.98), using C18 as the extraction phase. The extraction recovery of both systems was studied at different volumes of phosphate buffered saline (PBS). The distribution constant of SPME in thin-film geometry (i.e., thin-film microextraction/TFME) as well as the retention factor and breakthrough volume for the SPE system were evaluated for the simultaneous extraction of polar and non-polar compounds. Using 1 mL of sample, the extraction recovery and sensitivity of the SPE system (100 mg sorbent) was comparable with that of TFME format of SPME (15 mg sorbent) for all analytes, with the exception of most polar compounds, due to the smaller amount of the extraction phase in SPME. Breakthrough in the SPE system was observed for more polar compounds in a 25 mL sample; however, this situation did not affect the quantitation of TFME, as this technique operates in equilibrium mode. Experimental values for breakthrough volume were in good match with the calculated theoretical values. Results indicate that the microextraction approach is more suitable for untargeted determinations, where the breakthrough volume cannot be determined prior to the experiment. In addition, when both methods are at optimum conditions, findings suggest that, despite the smaller volume of the extraction phase in TFME, the sensitivity of TFME can exceed that of SPE for samples where the target analytes vary substantially in polarity. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 2000, SOLID PHASE EXTRACTI
[2]   Thin-film microextraction [J].
Bruheim, I ;
Liu, XC ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :1002-1010
[3]   A multi-fiber handling device for in vivo solid phase microextraction-liquid chromatography-mass spectrometry applications [J].
Cudjoe, Erasmus ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1232 :77-83
[4]   Investigation of the Effect of the Extraction Phase Geometry on the Performance of Automated Solid-Phase Microextraction [J].
Cudjoe, Erasmus ;
Vuckovic, Dajana ;
Hein, Dietmar ;
Pawliszyn, Janusz .
ANALYTICAL CHEMISTRY, 2009, 81 (11) :4226-4232
[5]   Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography [J].
Eisert, R ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3140-3147
[6]   Trace analysis of polar organic pollutants in aqueous samples - Tools for the rapid prediction and optimisation of the solid-phase extraction parameters [J].
Hennion, MC ;
Cau-Dit-Coumes, C ;
Pichon, V .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :147-161
[7]   Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography [J].
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :3-54
[8]   Fundamentals and applications of needle trap devices A critical review [J].
Lord, Heather L. ;
Zhan, Weiqiang ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2010, 677 (01) :3-18
[9]   Confirmatory analysis for drugs of abuse in plasma and urine by high-performance liquid chromatography-tandem mass spectrometry with respect to criteria for compound identification [J].
Maralikova, B ;
Weinmann, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 811 (01) :21-30
[10]   Automated determination of phenolic compounds in wine, berry, and grape samples using 96-blade solid phase microextraction system coupled with liquid chromatography-tandem mass spectrometry [J].
Mirnaghi, Fatemeh S. ;
Mousavi, Fatemeh ;
Rocha, Silvia M. ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1276 :12-19