Simulated internal defibrillation in humans using an anatomically realistic three-dimensional finite element model of the thorax

被引:18
作者
Kinst, TF
Sweeney, MO
Lehr, JL
Eisenberg, SR
机构
[1] BOSTON UNIV,DEPT BIOMED ENGN,BOSTON,MA 02215
[2] BRIGHAM & WOMENS HOSP,DEPT MED,DIV CARDIOVASC,BOSTON,MA 02115
[3] HARVARD UNIV,SCH MED,CAMBRIDGE,MA 02138
[4] BRIGHAM & WOMENS HOSP,DEPT CLIN ENGN,BOSTON,MA 02115
关键词
implantable defibrillator; defibrillation modeling; defibrillation metrics; computer models; catheter electrode;
D O I
10.1111/j.1540-8167.1997.tb00822.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Determination of the optimal electrode configuration during implantabIe cardioverter defibrillator (ICD) implantation remains largely an empirical process. This study investigated the feasibility of using a finite element model of the thorax to predict clinical defibrillation metrics for internal defibrillation in humans. Computed defibrillation metrics from simulations of three common electrode configurations with a monophasic waveform were compared to pooled metrics for similar electrode and waveform configurations reported in humans. Methods and Results: A three-dimensional finite element model was constructed from CT cross-sections of a human thorax. Myocardial current density distributions for three electrode configurations (epicardial patches, right ventricular [RV] coil/superior vena cave [SVC] coil, RV coil/SVC coil/subcutaneous patch) and a truncated monophasic pulse with a 65% tilt were simulated, Assuming an inexcitability threshold of 25 mA/cm(2) (10 V/cm) and a 75% critical mass criterion for successful defibrillation, defibrillation metrics (interelectrode impedance, defibrillation threshold current, voltage, and energy) were calculated for each electrode simulation. Values of these metrics were within 1 SD of sample-size weighted means for the corresponding metrics determined for similar electrode configurations and waveforms reported in human clinical studies. Simulated myocardial current density distributions suggest that variations in current distribution and uniformity partially explain differences in defibrillation energy requirements between electrode configurations. Conclusion: Anatomically realistic three-dimensional finite element modeling can closely simulate internal defibrillation in humans. This may prove useful for characterizing patient-specific factors that influence clinically relevant properties of current density distributions and defibrillation energy requirements of various ICD electrode configurations.
引用
收藏
页码:537 / 547
页数:11
相关论文
共 59 条
[21]  
JORGENSON DB, 1994, CIRCULATION, V90, pA945
[22]   EFFECTS OF CHRONIC AMIODARONE THERAPY ON DEFIBRILLATION THRESHOLD [J].
JUNG, W ;
MANZ, M ;
PIZZULLI, L ;
PFEIFFER, D ;
LUDERITZ, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (11) :1023-1027
[23]   NONTHORACOTOMY-IMPLANTABLE VERSUS THORACOTOMY-IMPLANTABLE DEFIBRILLATORS - INTENTION-TO-TREAT COMPARISON OF CLINICAL OUTCOMES [J].
KLEMAN, JM ;
CASTLE, LW ;
KIDWELL, GA ;
MALONEY, JD ;
MORANT, VA ;
TROHMAN, RG ;
WILKOFF, BL ;
MCCARTHY, PM ;
PINSKI, SL .
CIRCULATION, 1994, 90 (06) :2833-2842
[24]   3-DIMENSIONAL COMPUTER-MODEL OF ELECTRIC-FIELDS IN INTERNAL DEFIBRILLATION [J].
KOTHIYAL, KP ;
SHANKAR, B ;
FOGELSON, LJ ;
THAKOR, NV .
PROCEEDINGS OF THE IEEE, 1988, 76 (06) :720-730
[25]   EFFICACY OF A SINGLE-LEAD UNIPOLAR TRANSVENOUS DEFIBRILLATOR COMPARED WITH A SYSTEM EMPLOYING AN ADDITIONAL CORONARY SINUS ELECTRODE - A PROSPECTIVE, RANDOMIZED STUDY [J].
KUDENCHUK, PJ ;
BARDY, GH ;
DOLACK, GL ;
POOLE, JE ;
MEHRA, R ;
JOHNSON, G .
CIRCULATION, 1994, 89 (06) :2641-2644
[26]  
Ledley RS, 1977, CROSS SECTIONAL ANAT
[27]   PREDICTORS OF DEFIBRILLATION EFFICACY IN PATIENTS UNDERGOING EPICARDIAL DEFIBRILLATOR IMPLANTATION [J].
LEITCH, JW ;
YEE, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1632-1637
[28]   AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION WITHOUT THORACOTOMY USING AN ENDOCARDIAL AND SUBMUSCULAR PATCH SYSTEM [J].
MCCOWAN, R ;
MALONEY, J ;
WILKOFF, B ;
SIMMONS, T ;
KHOURY, D ;
MCALISTER, H ;
MORANT, V ;
CASTLE, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (02) :415-421
[29]  
MCDANIEL WC, 1987, MED INSTRUM, V21, P170
[30]   PRELIMINARY EXPERIENCE WITH A HYBRID NONTHORACOTOMY DEFIBRILLATING SYSTEM THAT INCLUDES A BIPHASIC DEVICE - COMPARISON WITH A STANDARD MONOPHASIC DEVICE USING THE SAME LEAD SYSTEM [J].
NATALE, A ;
SRA, J ;
AXTELL, K ;
MAGLIO, C ;
DHALA, A ;
DESHPANDE, S ;
JAZAYERI, M ;
WASE, A ;
AKHTAR, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :406-412